Abstract

The aim of this retrospective study was to determine factors that might cause complications in use of temporary anchorage devices (TADs) for orthodontic anchorage. We investigated 904 TADs in 455 patients. Clinical diagnoses requiring orthodontic treatment were malocclusion, jaw deformity, various syndromes, cleft lip and palate and impacted teeth. All patients underwent surgery at Tokyo Dental College Chiba Hospital between November 2000 and June 2009. Three kinds of titanium screw of different diameter and length were used: self-drilling mini-screws (Dual Top Autoscrew® and OSAS®), pre-drilling micro-screws (K1 system®) and palatal screws (PIAS®). Mini-plates fixed with 2 or 3 screws (SAS system®) were also used for skeletal anchorage. Patients were aged between 8 and 68 years (25.7±9.8 years). A total of 460 screw-type and 444 plate-type TADs were used. These comprised the following: mini-plates, 444; self-drilling mini-screws, 225; pre-drilling micro-screws, 83; and palatal screws, 152. Each type of implant had a high success rate of over about 90%. Failure rates were as follows: micro-screws, 7%; mini-screws, 6%; palatal implants, 11%; and mini-plates, 6%. Inflammation rate occurring in soft tissue surrounding TADs was follows: plate-type, 7.6%; mini-screws, 1.3%; micro-screws, 0%; and palatal implants, 2.5%. Inflammation frequencies depended on degree of mucosal penetration. Granulation rate in soft tissue surrounding TADs occurred as follows: micro-screws, 5.7%; self-drilling mini-screws, 0%; palatal screws, 0.6%; plate-type, 0.9%. Both plate- and screwtype orthodontic implants showed excellent clinical performance.

Entities:  

Mesh:

Year:  2010        PMID: 20877162     DOI: 10.2209/tdcpublication.51.151

Source DB:  PubMed          Journal:  Bull Tokyo Dent Coll        ISSN: 0040-8891


  9 in total

1.  Why are mini-implants lost: the value of the implantation technique!

Authors:  Fabio Lourenço Romano; Alberto Consolaro
Journal:  Dental Press J Orthod       Date:  2015 Jan-Feb

Review 2.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

3.  Reasons for mini-implants failure: choosing installation site should be valued!

Authors:  Alberto Consolaro; Fábio Lourenço Romano
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr

4.  Use of miniplates as a method for orthodontic anchorage: a case report.

Authors:  Fernando Gianzanti Peres; Luis Eduardo Marques Padovan; Leandro Eduardo Kluppel; Gustavo Calvalcanti Albuquerque; Paulo Cesar Ulson de Souza; Marcela Claudino
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

Review 5.  Profiles of inflammation factors and inflammatory pathways around the peri-miniscrew implant.

Authors:  Wendan He; Huazhang Zhu; Chufeng Liu
Journal:  Histol Histopathol       Date:  2021-04-09       Impact factor: 2.303

6.  Quantification of pro-inflammatory cytokines and osteoclastogenesis markers in successful and failed orthodontic mini-implants.

Authors:  Marcela Cristina Damião Andrucioli; Mírian Aiko Nakane Matsumoto; Sandra Yasuyo Fukada; Maria Conceição Pereira Saraiva; Ana Zilda Nazar Bergamo; Fábio Lourenço Romano; Raquel Assed Bezerra da Silva; Lea Assed Bezerra da Silva; Paulo Nelson-Filho
Journal:  J Appl Oral Sci       Date:  2019-10-07       Impact factor: 2.698

7.  Complications reported with the use of orthodontic miniscrews: A systematic review.

Authors:  Antonino Lo Giudice; Lorenzo Rustico; Miriam Longo; Giacomo Oteri; Moschos A Papadopoulos; Riccardo Nucera
Journal:  Korean J Orthod       Date:  2021-05-25       Impact factor: 1.372

Review 8.  Revisiting the Complications of Orthodontic Miniscrew.

Authors:  Van Mai Truong; Soyeon Kim; Jaeheon Kim; Joo Won Lee; Young-Seok Park
Journal:  Biomed Res Int       Date:  2022-08-01       Impact factor: 3.246

9.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.