Stephan Zellerhoff1, Matthew Daly2, Han S Lim2, Arnaud Denis3, Yuki Komatsu2, Laurence Jesel3, Nicolas Derval3, Frédéric Sacher3, Hubert Cochet3, Sébastien Knecht3, Sunthareth Yiem2, Mélèze Hocini3, Michel Haïssaguerre3, Pierre Jaïs3. 1. Hôpital Cardiologique du Haut-Lévêque, CHU Bordeaux, Université Victor Segalen Bordeaux II, Avenue de Magellan, 33604 Bordeaux-Pessac, France stephan.zellerhoff@ukmuenster.de. 2. Hôpital Cardiologique du Haut-Lévêque, CHU Bordeaux, Université Victor Segalen Bordeaux II, Avenue de Magellan, 33604 Bordeaux-Pessac, France. 3. Hôpital Cardiologique du Haut-Lévêque, CHU Bordeaux, Université Victor Segalen Bordeaux II, Avenue de Magellan, 33604 Bordeaux-Pessac, France INSERM U1045-L'Institut de Rythmologie et Modeling Cardiaque, Bordeaux, France.
Abstract
AIMS: Pulmonary vein isolation (PVI) is the mainstay of interventional treatment of paroxysmal atrial fibrillation (PAF). We report on the feasibility and efficacy of a novel, open-irrigated mapping and radiofrequency (RF) ablation catheter. METHODS AND RESULTS: Thirty-nine consecutive patients (pts; age 60 ± 10 years, 8 females) suffering from drug-refractory PAF referred for PVI were included in this prospective study. Pulmonary vein isolation was performed with the use of a novel 10-pole circular, open-irrigated mapping and ablation catheter (nMARQ, Biosense Webster). Outcome parameters were the acute success rate in establishing complete PVI and the rate of sustained sinus rhythm (SR) during follow-up (FU). Ten patients underwent a repeat procedure for recurrent AF. Ninety-eight percent of the PVs could be acutely isolated using solely the nMARQ catheter by applying a mean total of 10.0 ± 4.6 min of RF energy. The mean total procedure duration was 86 ± 29 min, and the mean fluoroscopy time was 22.2 ± 6.5 min, respectively. Transient reconnection provoked by adenosine was observed in 10 of 24 patients, most frequently in the right superior PV. Cardiac tamponade related to transseptal puncture occurred in one patient. Reconnected PVs could be identified as a source of recurrent AF in 9 of 10 patients undergoing a repeat procedure. Single and multiple procedure success rates during a mean FU of 140 ± 75 days were 66 and 77%, respectively. CONCLUSION: Irrigated multi-electrode RF ablation is fast and effective, providing a high rate of isolated PVs without the need of touch-up lesions. Success rates were comparable with other techniques with a low complication rate. Recurrences of AF were mainly due to recovered pulmonary vein/left atrium conduction. Published on behalf of the European Society of Cardiology. All rights reserved.
AIMS: Pulmonary vein isolation (PVI) is the mainstay of interventional treatment of paroxysmal atrial fibrillation (PAF). We report on the feasibility and efficacy of a novel, open-irrigated mapping and radiofrequency (RF) ablation catheter. METHODS AND RESULTS: Thirty-nine consecutive patients (pts; age 60 ± 10 years, 8 females) suffering from drug-refractory PAF referred for PVI were included in this prospective study. Pulmonary vein isolation was performed with the use of a novel 10-pole circular, open-irrigated mapping and ablation catheter (nMARQ, Biosense Webster). Outcome parameters were the acute success rate in establishing complete PVI and the rate of sustained sinus rhythm (SR) during follow-up (FU). Ten patients underwent a repeat procedure for recurrent AF. Ninety-eight percent of the PVs could be acutely isolated using solely the nMARQ catheter by applying a mean total of 10.0 ± 4.6 min of RF energy. The mean total procedure duration was 86 ± 29 min, and the mean fluoroscopy time was 22.2 ± 6.5 min, respectively. Transient reconnection provoked by adenosine was observed in 10 of 24 patients, most frequently in the right superior PV. Cardiac tamponade related to transseptal puncture occurred in one patient. Reconnected PVs could be identified as a source of recurrent AF in 9 of 10 patients undergoing a repeat procedure. Single and multiple procedure success rates during a mean FU of 140 ± 75 days were 66 and 77%, respectively. CONCLUSION: Irrigated multi-electrode RF ablation is fast and effective, providing a high rate of isolated PVs without the need of touch-up lesions. Success rates were comparable with other techniques with a low complication rate. Recurrences of AF were mainly due to recovered pulmonary vein/left atrium conduction. Published on behalf of the European Society of Cardiology. All rights reserved.
Authors: Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane Journal: Heart Rhythm Date: 2017-05-12 Impact factor: 6.343
Authors: Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber Journal: Heart Rhythm Date: 2012-03-01 Impact factor: 6.343
Authors: Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane Journal: Europace Date: 2018-01-01 Impact factor: 5.214
Authors: Antonio Dello Russo; Gaetano Fassini; Michela Casella; Antonio Di Monaco; Stefania Riva; Valentina Romano; Massimo Moltrasio; Fabrizio Tundo; Giuseppe De Martino; Benedetta Majocchi; Vittoria Marino; Eleonora Russo; Francesca Pizzamiglio; Giuseppe Del Giorno; Gemma Pelargonio; Luigi Di Biase; Andrea Natale; Claudio Tondo Journal: J Interv Card Electrophysiol Date: 2015-06-23 Impact factor: 1.900
Authors: Faisal M Merchant; Mathew R Levy; Shahriar Iravanian; Edward C Clermont; Heval M Kelli; Robert L Eisner; Mikhael F El-Chami; Angel R Leon; David B Delurgio Journal: J Interv Card Electrophysiol Date: 2016-01-26 Impact factor: 1.900