Inaccurate calculation of drug output from nebulisers.

C O'Callaghan1, A R Clarke, A D Milner.   

Abstract

A multistage liquid impinger was used to collect the nebulised cloud from three separate nebulisers. The output of sodium cromoglycate collected was determined by a spectrophotometric assay. Estimating drug output purely from weight loss during nebulisation resulted in a considerable overestimate compared with direct assay of the drug output from the nebulised cloud. During nebulisation, weight loss from the nebuliser occurs in the form of particle formation and also by evaporation. By only weighing the nebuliser chamber before and after nebulisation, weight loss due to evaporation is not taken into account and this is the cause of the overestimation of drug output by this method.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2493380     DOI: 10.1007/bf00595919

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  5 in total

1.  Evaluation of nebulisers for bronchial challenge tests.

Authors:  J N Tsanakas; A J Wilson; A W Boon
Journal:  Arch Dis Child       Date:  1987-05       Impact factor: 3.791

2.  Is driving gas flow rate clinically important for nebulizer therapy?

Authors:  J W Hadfield; W J Windebank; J R Bateman
Journal:  Br J Dis Chest       Date:  1986-01

3.  Variation in delivery of isoprenaline from various pressurized inhalers.

Authors:  J H Bell; K Brown; J Glasby
Journal:  J Pharm Pharmacol       Date:  1973-12       Impact factor: 3.765

4.  Aerosols and humidity therapy. Generation and respiratory deposition of therapeutic aerosols.

Authors:  D L Swift
Journal:  Am Rev Respir Dis       Date:  1980-11

5.  A comparative study of two doses of salbutamol nebulized at 4 and 8 litres per minute in patients with chronic asthma.

Authors:  J G Douglas; M J Leslie; G K Crompton; I W Grant
Journal:  Br J Dis Chest       Date:  1986-01
  5 in total
  4 in total

1.  Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.

Authors:  J H Dennis; S C Stenton; J R Beach; A J Avery; E H Walters; D J Hendrick
Journal:  Thorax       Date:  1990-10       Impact factor: 9.139

Review 2.  Aerosol therapy in the newborn.

Authors:  M Silverman
Journal:  Arch Dis Child       Date:  1990-08       Impact factor: 3.791

3.  Nebulization of liposomes. II. The effects of size and modeling of solute release profiles.

Authors:  R W Niven; M Speer; H Schreier
Journal:  Pharm Res       Date:  1991-02       Impact factor: 4.200

Review 4.  Aerosols for therapy and diagnosis.

Authors:  M J O'Doherty; R F Miller
Journal:  Eur J Nucl Med       Date:  1993-12
  4 in total