Literature DB >> 24931305

Comparison of three modifications of fused-silica capillaries and untreated capillaries for protein profiling of maize extracts by capillary electrophoresis.

Ewa Pobozy1, Aleksandra Sentkowska, Anna Piskor.   

Abstract

In this work, capillary electrophoresis was applied to protein profiling of fractionated extracts of maize. A comparative study on the application of uncoated fused-silica capillaries and capillaries modified with hydroxypropylmethylcellulose, ω-iodoalkylammonium salt and a commercially available neutral capillary covalently coated with polyacrylamide is presented. The coating stability, background electrolyte composition, and separation efficiency were investigated. It was found that for zeins separation, the most stable and efficient was the capillary coated with polyacrylamide. Finally, the usefulness of these methods was studied for the differentiation of zein fraction in transgenic and nontransgenic maize. Zeins extracted from maize standards containing 0 and 5% m/m genetic modification were successfully separated, but slight differences were observed in terms of the zein content. Albumin and globulin fractions were analyzed with the use of unmodified fused-silica capillary with borate buffer pH 9 and the capillary coated with polyacrylamide with phosphate buffer pH 3. In the albumin fraction, additional peaks were found in genetically modified samples.
© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Capillary coating; Capillary electrophoresis; Genetic modification; Maize; Protein profiling

Mesh:

Substances:

Year:  2014        PMID: 24931305     DOI: 10.1002/jssc.201301236

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

Review 1.  Recent advances in protein analysis by capillary and microchip electrophoresis.

Authors:  Mohamed Dawod; Natalie E Arvin; Robert T Kennedy
Journal:  Analyst       Date:  2017-05-30       Impact factor: 4.616

Review 2.  Characterization and study of transgenic cultivars by capillary and microchip electrophoresis.

Authors:  Elena Domínguez Vega; Maria Luisa Marina
Journal:  Int J Mol Sci       Date:  2014-12-22       Impact factor: 5.923

3.  Improving repeatability of capillary electrophoresis-a critical comparison of ten different capillary inner surfaces and three criteria of peak identification.

Authors:  Paweł Mateusz Nowak; Michał Woźniakiewicz; Marta Gładysz; Magdalena Janus; Paweł Kościelniak
Journal:  Anal Bioanal Chem       Date:  2017-05-08       Impact factor: 4.142

4.  Capillary coating as an important factor in optimization of the off-line and on-line MEKC assays of the highly hydrophobic enzyme chlorophyllase.

Authors:  Paweł Mateusz Nowak; Michał Woźniakiewicz; Maciej Michalik; Leszek Fiedor; Paweł Kościelniak
Journal:  Anal Bioanal Chem       Date:  2016-11-25       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.