The effect of a polyurethane coating incorporating both a thrombin inhibitor and nitric oxide on hemocompatibility in extracorporeal circulation.

Terry C Major1, Elizabeth J Brisbois2, Anna M Jones3, Margaux E Zanetti3, Gail M Annich4, Robert H Bartlett3, Hitesh Handa5.   

Abstract

Nitric oxide (NO) releasing (NORel) materials have been extensively investigated to create localized increases in NO concentration by the proton driven diazeniumdiolate-containing polymer coatings and demonstrated to improve extracorporeal circulation (ECC) hemocompatibility. In this work, the NORel polymeric coating composed of a diazeniumdiolated dibutylhexanediamine (DBHD-N2O2)-containing hydrophobic Elast-eon™ (E2As) polyurethane was combined with a direct thrombin inhibitor, argatroban (AG), and evaluated in a 4 h rabbit thrombogenicity model without systemic anticoagulation. In addition, the immobilizing of argatroban to E2As polymer was achieved by either a polyethylene glycol-containing (PEGDI) or hexane methylene (HMDI) diisocyanate linker. The combined polymer film was coated on the inner walls of ECC circuits to yield significantly reduced ECC thrombus formation compared to argatroban alone ECC control after 4 h blood exposure (0.6 ± 0.1 AG/HMDI/NORel vs 1.7 ± 0.2 cm(2) AG/HMDI control). Platelet count (2.8 ± 0.3 AG/HMDI/NORel vs 1.9 ± 0.1 × 10(8)/ml AG/HMDI control) and plasma fibrinogen levels were preserved after 4 h blood exposure with both the NORel/argatroban combination and the AG/HMDI control group compared to baseline. Platelet function as measured by aggregometry remained near normal in both the AG/HMDI/NORel (63 ± 5%) and AG/HMDI control (58 ± 7%) groups after 3 h compared to baseline (77 ± 1%). Platelet P-selectin mean fluorescence intensity (MFI) as measured by flow cytometry also remained near baseline levels after 4 h on ECC to ex vivo collagen stimulation (16 ± 3 AG/HMDI/NORel vs 11 ± 2 MFI baseline). These results suggest that the combined AG/HMDI/NORel polymer coating preserves platelets in blood exposure to ECCs to a better degree than AG/PEGDI/NORel, NORel alone or AG alone. These combined antithrombin, NO-mediated antiplatelet effects were shown to improve thromboresistance of the AG/HMDI/NORel polymer-coated ECCs and move potential nonthrombogenic polymers closer to mimicking vascular endothelium.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Argatroban; Direct thrombin inhibition; Hexane methylene diisocyanate (HMDI); Nitric oxide releasing polymer; Polyethylene glycol (PEG); Thrombogenicity

Mesh:

Substances:

Year:  2014        PMID: 24927680      PMCID: PMC4099065          DOI: 10.1016/j.biomaterials.2014.05.036

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  49 in total

1.  Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

Authors:  Gemma Conn; Asmeret G Kidane; Geoffrey Punshon; Ruben Y Kannan; George Hamilton; Alexander M Seifalian
Journal:  Expert Rev Med Devices       Date:  2006-03       Impact factor: 3.166

2.  Closed, phosphorylcholine-coated circuit and reduction of systemic heparinization for cardiopulmonary bypass: the intraoperative ECMO concept.

Authors:  M Ranucci; A Pazzaglia; G Isgrò; A Cazzaniga; A Ditta; A Boncilli; M Cotza; G Carboni; S Brozzi; C Bonifazi
Journal:  Int J Artif Organs       Date:  2002-09       Impact factor: 1.595

3.  Nitric oxide releasing silicone rubbers with improved blood compatibility: preparation, characterization, and in vivo evaluation.

Authors:  Huiping Zhang; Gail M Annich; Judiann Miskulin; Kathryn Osterholzer; Scott I Merz; Robert H Bartlett; Mark E Meyerhoff
Journal:  Biomaterials       Date:  2002-03       Impact factor: 12.479

4.  Preparation and characterization of polymeric coatings with combined nitric oxide release and immobilized active heparin.

Authors:  Zhengrong Zhou; Mark E Meyerhoff
Journal:  Biomaterials       Date:  2005-11       Impact factor: 12.479

5.  Chemical modification of poly(vinyl chloride) resin using poly(ethylene glycol) to improve blood compatibility.

Authors:  Biji Balakrishnan; D S Kumar; Yasuhiko Yoshida; A Jayakrishnan
Journal:  Biomaterials       Date:  2005-06       Impact factor: 12.479

Review 6.  Polymers incorporating nitric oxide releasing/generating substances for improved biocompatibility of blood-contacting medical devices.

Authors:  Megan C Frost; Melissa M Reynolds; Mark E Meyerhoff
Journal:  Biomaterials       Date:  2005-05       Impact factor: 12.479

7.  Platelet-leukocyte mixed conjugates in patients with atrial fibrillation.

Authors:  Silvia Alberti; Giulia Angeloni; Chiara Tamburrelli; Agnieszka Pampuch; Benedetta Izzi; Loredana Messano; Quintino Parisi; Matteo Santamaria; Maria Benedetta Donati; Giovanni de Gaetano; Chiara Cerletti
Journal:  Platelets       Date:  2009-06       Impact factor: 3.862

8.  In vitro and in vivo study of sustained nitric oxide release coating using diazeniumdiolate-oped poly(vinyl chloride) matrix with poly(lactide-co-glycolide) additive.

Authors:  Hitesh Handa; Elizabeth J Brisbois; Terry C Major; Lahdan Refahiyat; Kagya A Amoako; Gail M Annich; Robert H Bartlett; Mark E Meyerhoff
Journal:  J Mater Chem B       Date:  2013-08-07       Impact factor: 6.331

9.  More lipophilic dialkyldiamine-based diazeniumdiolates: synthesis, characterization, and application in preparing thromboresistant nitric oxide release polymeric coatings.

Authors:  Melissa M Batchelor; Sylvie L Reoma; Paul S Fleser; Vijay K Nuthakki; Rose E Callahan; Charles J Shanley; Jeffrey K Politis; Jessica Elmore; Scott I Merz; Mark E Meyerhoff
Journal:  J Med Chem       Date:  2003-11-20       Impact factor: 7.446

10.  Comparison of heparin-coated and conventional split-tip hemodialysis catheters.

Authors:  Timothy W I Clark; David Jacobs; Hearns W Charles; Sandor Kovacs; Theresa Aquino; Joseph Erinjeri; Judith A Benstein
Journal:  Cardiovasc Intervent Radiol       Date:  2009-06-02       Impact factor: 2.797

View more
  26 in total

Review 1.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

2.  Improved Hemocompatibility of Multilumen Catheters via Nitric Oxide (NO) Release from S-Nitroso-N-acetylpenicillamine (SNAP) Composite Filled Lumen.

Authors:  Elizabeth J Brisbois; Maria Kim; Xuewei Wang; Azmath Mohammed; Terry C Major; Jianfeng Wu; Jessica Brownstein; Chuanwu Xi; Hitesh Handa; Robert H Bartlett; Mark E Meyerhoff
Journal:  ACS Appl Mater Interfaces       Date:  2016-10-21       Impact factor: 9.229

3.  Catalyzed Nitric Oxide Release Via Cu Nanoparticles Leads to an Increase in Antimicrobial Effects and Hemocompatibility for Short Term Extracorporeal Circulation.

Authors:  Megan E Douglass; Marcus J Goudie; Jitendra Pant; Priyadarshini Singha; Sean Hopkins; Ryan Devine; Chad W Schmiedt; Hitesh Handa
Journal:  ACS Appl Bio Mater       Date:  2019-05-07

4.  Mimicking the Endothelium: Dual Action Heparinized Nitric Oxide Releasing Surface.

Authors:  Ryan Devine; Marcus J Goudie; Priyadarshini Singha; Chad Schmiedt; Megan Douglass; Elizabeth J Brisbois; Hitesh Handa
Journal:  ACS Appl Mater Interfaces       Date:  2020-04-22       Impact factor: 9.229

5.  Achieving Long-Term Biocompatible Silicone via Covalently Immobilized S-Nitroso- N-acetylpenicillamine (SNAP) That Exhibits 4 Months of Sustained Nitric Oxide Release.

Authors:  Sean P Hopkins; Jitendra Pant; Marcus J Goudie; Chad Schmiedt; Hitesh Handa
Journal:  ACS Appl Mater Interfaces       Date:  2018-08-01       Impact factor: 9.229

6.  The immobilization of a direct thrombin inhibitor to a polyurethane as a nonthrombogenic surface coating for extracorporeal circulation.

Authors:  Jane Yu; Elizabeth Brisbois; Hitesh Handa; Gail Annich; Mark Meyerhoff; Robert Bartlett; Terry Major
Journal:  J Mater Chem B       Date:  2016-03-01       Impact factor: 6.331

7.  Attenuation of thrombosis and bacterial infection using dual function nitric oxide releasing central venous catheters in a 9day rabbit model.

Authors:  Elizabeth J Brisbois; Terry C Major; Marcus J Goudie; Mark E Meyerhoff; Robert H Bartlett; Hitesh Handa
Journal:  Acta Biomater       Date:  2016-08-06       Impact factor: 8.947

8.  Improved hemocompatibility of silicone rubber extracorporeal tubing via solvent swelling-impregnation of S-nitroso-N-acetylpenicillamine (SNAP) and evaluation in rabbit thrombogenicity model.

Authors:  Elizabeth J Brisbois; Terry C Major; Marcus J Goudie; Robert H Bartlett; Mark E Meyerhoff; Hitesh Handa
Journal:  Acta Biomater       Date:  2016-04-16       Impact factor: 8.947

Review 9.  Recent advances in thromboresistant and antimicrobial polymers for biomedical applications: just say yes to nitric oxide (NO).

Authors:  Yaqi Wo; Elizabeth J Brisbois; Robert H Bartlett; Mark E Meyerhoff
Journal:  Biomater Sci       Date:  2016-05-26       Impact factor: 6.843

10.  Synthesis and biocompatibility of an argatroban-modified polysulfone membrane that directly inhibits thrombosis.

Authors:  Xiao Fu; Jian-Ping Ning
Journal:  J Mater Sci Mater Med       Date:  2018-05-09       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.