Literature DB >> 32271542

Mimicking the Endothelium: Dual Action Heparinized Nitric Oxide Releasing Surface.

Ryan Devine1, Marcus J Goudie1, Priyadarshini Singha1, Chad Schmiedt2, Megan Douglass1, Elizabeth J Brisbois3, Hitesh Handa1.   

Abstract

The management of thrombosis and bacterial infection is critical to ensure the functionality of medical devices. While administration of anticoagulants is the current antithrombotic clinical practice, a variety of complications, such as uncontrolled hemorrhages or heparin-induced thrombocytopenia, can occur. Additionally, infection rates remain a costly and deadly complication associated with use of these medical devices. It has been hypothesized that if a synthetic surface could mimic the biochemical mechanisms of the endothelium of blood vessels, thrombosis could be reduced, anticoagulant use could be avoided, and infection could be prevented. Herein, the interfacial biochemical effects of the endothelium were mimicked by altering the surface of medical grade silicone rubber (SR). Surface modification was accomplished via heparin surface immobilization (Hep) and the inclusion of a nitric oxide (NO) donor into the SR polymeric matrix to achieve synergistic effects (Hep-NO-SR). An in vitro bacteria adhesion study revealed that Hep-NO-SR exhibited a 99.46 ± 0.17% reduction in viable bacteria adhesion compared to SR. An in vitro platelet study revealed Hep-NO-SR reduced platelet adhesion by 84.12 ± 6.19% compared to SR, while not generating a cytotoxic response against fibroblast cells. In a 4 h extracorporeal circuit model without systemic anticoagulation, all Hep-NO-SR samples were able to maintain baseline platelet count and device patency; whereas 66% of SR samples clotted within the first 2 h of study. Results indicate that Hep-NO-SR creates a more hemocompatible and antibacterial surface by mimicking two key biochemical functions of the native endothelium.

Entities:  

Keywords:  antifouling; biomaterials; hemocompatibility; heparin; nitric oxide

Mesh:

Substances:

Year:  2020        PMID: 32271542      PMCID: PMC7962625          DOI: 10.1021/acsami.9b22277

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  78 in total

1.  Bacterial biofilm formation on urologic devices and heparin coating as preventive strategy.

Authors:  Peter Tenke; Claus R Riedl; Gwennan Ll Jones; Gareth J Williams; David Stickler; Elisabeth Nagy
Journal:  Int J Antimicrob Agents       Date:  2004-03       Impact factor: 5.283

Review 2.  Mechanisms of platelet activation by thrombin: a short history.

Authors:  Erica De Candia
Journal:  Thromb Res       Date:  2011-12-02       Impact factor: 3.944

3.  Covalent Grafting of Antifouling Phosphorylcholine-Based Copolymers with Antimicrobial Nitric Oxide Releasing Polymers to Enhance Infection-Resistant Properties of Medical Device Coatings.

Authors:  Qiaohong Liu; Priyadarshini Singha; Hitesh Handa; Jason Locklin
Journal:  Langmuir       Date:  2017-10-30       Impact factor: 3.882

4.  Platelet activation by heparin.

Authors:  Andreas Greinacher
Journal:  Blood       Date:  2011-05-05       Impact factor: 22.113

5.  Characterization of an S-nitroso-N-acetylpenicillamine-based nitric oxide releasing polymer from a translational perspective.

Authors:  Marcus J Goudie; Elizabeth J Brisbois; Jitendra Pant; Alex Thompson; Joseph A Potkay; Hitesh Handa
Journal:  Int J Polym Mater       Date:  2016-06-15       Impact factor: 2.604

6.  Duration of prophylaxis against venous thromboembolism with enoxaparin after surgery for cancer.

Authors:  David Bergqvist; Giancarlo Agnelli; Alexander T Cohen; Amiram Eldor; Paul E Nilsson; Anne Le Moigne-Amrani; Flavia Dietrich-Neto
Journal:  N Engl J Med       Date:  2002-03-28       Impact factor: 91.245

Review 7.  Staphylococcal infections: mechanisms of biofilm maturation and detachment as critical determinants of pathogenicity.

Authors:  Michael Otto
Journal:  Annu Rev Med       Date:  2012-08-16       Impact factor: 13.739

8.  Nitric oxide releasing polyurethanes with covalently linked diazeniumdiolated secondary amines.

Authors:  Melissa M Reynolds; Joseph A Hrabie; Bong K Oh; Jeffrey K Politis; Michael L Citro; Larry K Keefer; Mark E Meyerhoff
Journal:  Biomacromolecules       Date:  2006-03       Impact factor: 6.988

9.  Does heparin coating improve patency or reduce infection of tunneled dialysis catheters?

Authors:  Gaurav Jain; Michael Allon; Souheil Saddekni; Jill-Finkel Barker; Ivan D Maya
Journal:  Clin J Am Soc Nephrol       Date:  2009-09-03       Impact factor: 8.237

Review 10.  Endothelial cell control of thrombosis.

Authors:  Jonathan W Yau; Hwee Teoh; Subodh Verma
Journal:  BMC Cardiovasc Disord       Date:  2015-10-19       Impact factor: 2.298

View more
  4 in total

1.  Combination strategies for antithrombotic biomaterials: an emerging trend towards hemocompatibility.

Authors:  Morgan Ashcraft; Megan Douglass; YuJie Chen; Hitesh Handa
Journal:  Biomater Sci       Date:  2021-02-18       Impact factor: 6.843

2.  S-Nitroso-N-acetyl-l-cysteine Ethyl Ester (SNACET) Catheter Lock Solution to Reduce Catheter-Associated Infections.

Authors:  Rajnish Kumar; Hamed Massoumi; Manjyot Kaur Chug; Elizabeth J Brisbois
Journal:  ACS Appl Mater Interfaces       Date:  2021-05-24       Impact factor: 10.383

Review 3.  Recent Developments in Multifunctional Antimicrobial Surfaces and Applications toward Advanced Nitric Oxide-Based Biomaterials.

Authors:  Manjyot Kaur Chug; Elizabeth J Brisbois
Journal:  ACS Mater Au       Date:  2022-08-08

4.  Reply to the "Comment on 'A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress'" by Li Wang, Fang Li, Zhichun Feng, Yuan Shi.

Authors:  Niels Rochow; Christoph Fusch; Ponnambalam Ravi Selvaganapathy
Journal:  Adv Sci (Weinh)       Date:  2021-05-04       Impact factor: 16.806

  4 in total