Literature DB >> 24926649

A reduction in errors is associated with prospectively recording them.

Adetunji A Oremakinde1, Mark Bernstein.   

Abstract

OBJECT: Error recording and monitoring is an important component of error prevention and quality assurance in the health sector given the huge impact of medical errors on the well-being of patients and the financial loss incurred by health institutions. With this in mind, assessing the effect of reporting errors should be a cause worth pursuing. The object in this study was to examine the null hypothesis that recording and publishing errors do not affect error patterns in a clinical practice.
METHODS: Intraoperative errors and their characteristics were prospectively recorded between May 2000 and May 2013 in the neurosurgical practice of the senior author (M.B.). The error pattern observed between May 2000 and August 2006, which has been previously described (Group A), was compared with the error pattern observed between September 2006 and May 2013 (Group B).
RESULTS: A total of 1108 cases in Group A and 974 cases in Group B were surgically treated. A total of 2684 errors were recorded in Group A, while 1892 errors were recorded in Group B. The ratios of cranial to spinal procedures performed in Groups A and B were 3:1 and 10:1, respectively, while the ratios of general to local anesthesia in the two groups were 2:1 and 1.3:1, respectively (p < 0.0001 for both). There was a significantly decreased proportion of cases with error (87% to 83%, p < 0.006), mean errors per case (2.4 to 1.9, p < 0.0001), proportion of error-related complications (16.7% to 5.5%, p < 0.002), and clinical impacts of error (2.7% to 1.0%, p < 0.0001) in Group B compared with Group A. Errors in Group B tended to be more preventable than those in Group A (85.8% vs 78.5%, p < 0.0001). A significant reduction was also noticed with most types of error. A descending trend in the mean errors per case was demonstrated from the years 2001 to 2012; however, an increased severity of errors (22.6% to 29.5%, p < 0.0001) was recorded in Group B compared with Group A.
CONCLUSIONS: Data in this study showed that the act of recording errors might alter behaviors, resulting in fewer errors.

Entities:  

Keywords:  ASA = American Society of Anesthesiologists; error recording; intraoperative error; neurosurgery; prospective study

Mesh:

Year:  2014        PMID: 24926649     DOI: 10.3171/2014.5.JNS132341

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  3 in total

1.  Patient-specific neurosurgical phantom: assessment of visual quality, accuracy, and scaling effects.

Authors:  Felipe Wilker Grillo; Victor Hugo Souza; Renan Hiroshi Matsuda; Carlo Rondinoni; Theo Zeferino Pavan; Oswaldo Baffa; Helio Rubens Machado; Antonio Adilton Oliveira Carneiro
Journal:  3D Print Med       Date:  2018-03-13

Review 2.  Legal perspectives on black box recording devices in the operating environment.

Authors:  A S H M van Dalen; J Legemaate; W S Schlack; D A Legemate; M P Schijven
Journal:  Br J Surg       Date:  2019-05-21       Impact factor: 6.939

3.  Prevalence of Near-miss Events of Transfusion Practice and Its Associated Factors amongst House Officers in a Teaching Hospital.

Authors:  Noor Haslina Mohd Noor; Kimberly Fe Joibe; Mohd Nazri Hasan
Journal:  Oman Med J       Date:  2021-03-31
  3 in total