Literature DB >> 24922188

SiPM optical crosstalk amplification due to scintillator crystal: effects on timing performance.

Alberto Gola1, Alessandro Ferri, Alessandro Tarolli, Nicola Zorzi, Claudio Piemonte.   

Abstract

For a given photon detection efficiency (PDE), the primary, Poisson distributed, dark count rate of the detector (DCR0) is one of the most limiting factors affecting the timing resolution of a silicon photomultiplier (SiPM) in the scintillation light readout. If the effects of DCR0 are removed through a suitable baseline compensation algorithm or by cooling, it is possible to clearly observe another phenomenon that limits the PDE, and thus the timing resolution of the detector. It is caused by the optical crosstalk of the SiPM, which is significantly increased by the presence of the scintillator. In this paper, we describe this phenomenon, which is also easily observed from the reverse I-V curve of the device, and we relate it to the measured coincidence resolving time in 511 keV γ-ray measurements. We discuss its consequences on the SiPM design and, in particular, we observe that there is an optimal cell size, dependent on both SiPM and crystal parameters, that maximizes the PDE in presence of optical crosstalk. Finally, we report on a crosstalk simulator developed to study the phenomenon and we compare the simulation results obtained for different SiPM technologies, featuring different approaches to the reduction of the crosstalk.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24922188     DOI: 10.1088/0031-9155/59/13/3615

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Can PET be performed without an attenuation scan?

Authors:  Colin Jones; Ran Klein
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

Review 2.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

3.  Highly multiplexed signal readout for a time-of-flight positron emission tomography detector based on silicon photomultipliers.

Authors:  Joshua W Cates; Matthew F Bieniosek; Craig S Levin
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-23

4.  Optimizing Silicon photomultipliers for Quantum Optics.

Authors:  Giovanni Chesi; Luca Malinverno; Alessia Allevi; Romualdo Santoro; Massimo Caccia; Alexander Martemiyanov; Maria Bondani
Journal:  Sci Rep       Date:  2019-05-15       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.