Literature DB >> 24919645

Comparison of the performance of Ion Torrent chips in noninvasive prenatal trisomy detection.

Yanlin Wang1, Zujia Wen2, Jiawei Shen2, Weiwei Cheng3, Jun Li4, Xiaolan Qin5, Duan Ma6, Yongyong Shi2.   

Abstract

Semiconductor high-throughput sequencing, represented by Ion Torrent PGM/Proton, proves to be feasible in the noninvasive prenatal diagnosis of fetal aneuploidies. It is commendable that, with less data and relevant cost also, an accurate result can be achieved owing to the high sensitivity and specificity of such kind of technology. We conducted a comparative analysis of the performance of four different Ion chips in detecting fetal chromosomal aneuploidies. Eight maternal plasma DNA samples, including four pregnancies with normal fetuses and four with trisomy 21 fetuses, were sequenced on Ion Torrent 314/316/318/PI chips, respectively. Results such as read mapped ratio, correlation coefficient and phred quality score were calculated and parallelly compared. All samples were correctly classified even with low-throughput chip, and, among the four chips, the 316 chip had the highest read mapped ratio, correlation coefficient, mean read length and phred quality score. All chips were well consistent with each other. Our results showed that all Ion chips are applicable in noninvasive prenatal fetal aneuploidy diagnosis. We recommend researchers or clinicians to use the appropriate chip with barcoding technology on the basis of the sample number.

Entities:  

Mesh:

Year:  2014        PMID: 24919645     DOI: 10.1038/jhg.2014.40

Source DB:  PubMed          Journal:  J Hum Genet        ISSN: 1434-5161            Impact factor:   3.172


  9 in total

1.  Presence of fetal DNA in maternal plasma and serum.

Authors:  Y M Lo; N Corbetta; P F Chamberlain; V Rai; I L Sargent; C W Redman; J S Wainscoat
Journal:  Lancet       Date:  1997-08-16       Impact factor: 79.321

2.  What potent blood: non-invasive prenatal genetic diagnosis and the transformation of modern prenatal care.

Authors:  Carolyn Jacobs Chachkin
Journal:  Am J Law Med       Date:  2007

3.  Microfluidics digital PCR reveals a higher than expected fraction of fetal DNA in maternal plasma.

Authors:  Fiona M F Lun; Rossa W K Chiu; K C Allen Chan; Tak Yeung Leung; Tze Kin Lau; Y M Dennis Lo
Journal:  Clin Chem       Date:  2008-08-14       Impact factor: 8.327

Review 4.  Clinical practice. Prenatal screening for aneuploidy.

Authors:  Deborah A Driscoll; Susan Gross
Journal:  N Engl J Med       Date:  2009-06-11       Impact factor: 91.245

5.  Quantitative analysis of fetal DNA in maternal plasma and serum: implications for noninvasive prenatal diagnosis.

Authors:  Y M Lo; M S Tein; T K Lau; C J Haines; T N Leung; P M Poon; J S Wainscoat; P J Johnson; A M Chang; N M Hjelm
Journal:  Am J Hum Genet       Date:  1998-04       Impact factor: 11.025

6.  Non-invasive prenatal assessment of trisomy 21 by multiplexed maternal plasma DNA sequencing: large scale validity study.

Authors:  Rossa W K Chiu; Ranjit Akolekar; Yama W L Zheng; Tak Y Leung; Hao Sun; K C Allen Chan; Fiona M F Lun; Attie T J I Go; Elizabeth T Lau; William W K To; Wing C Leung; Rebecca Y K Tang; Sidney K C Au-Yeung; Helena Lam; Yu Y Kung; Xiuqing Zhang; John M G van Vugt; Ryoko Minekawa; Mary H Y Tang; Jun Wang; Cees B M Oudejans; Tze K Lau; Kypros H Nicolaides; Y M Dennis Lo
Journal:  BMJ       Date:  2011-01-11

7.  Noninvasive prenatal diagnosis of fetal chromosomal aneuploidy by massively parallel genomic sequencing of DNA in maternal plasma.

Authors:  Rossa W K Chiu; K C Allen Chan; Yuan Gao; Virginia Y M Lau; Wenli Zheng; Tak Y Leung; Chris H F Foo; Bin Xie; Nancy B Y Tsui; Fiona M F Lun; Benny C Y Zee; Tze K Lau; Charles R Cantor; Y M Dennis Lo
Journal:  Proc Natl Acad Sci U S A       Date:  2008-12-10       Impact factor: 11.205

8.  Noninvasive diagnosis of fetal aneuploidy by shotgun sequencing DNA from maternal blood.

Authors:  H Christina Fan; Yair J Blumenfeld; Usha Chitkara; Louanne Hudgins; Stephen R Quake
Journal:  Proc Natl Acad Sci U S A       Date:  2008-10-06       Impact factor: 11.205

9.  Feasibility study of semiconductor sequencing for noninvasive prenatal detection of fetal aneuploidy.

Authors:  Yuan Yuan; Fuman Jiang; Sang Hua; Bole Du; Yibin Hao; Lili Ye; Jiucheng Liu; Kaiyan Feng; Xinjie Huang; Xin Yi; Wei Wang; Ling Yang; Feng Mu; Caixia Liu; Yu Liang
Journal:  Clin Chem       Date:  2013-01-30       Impact factor: 8.327

  9 in total
  6 in total

1.  Noninvasive fetal trisomy detection by multiplexed semiconductor sequencing: a barcoding analysis strategy.

Authors:  Jiawei Shen; Zujia Wen; Xiaolan Qin; Yongyong Shi
Journal:  J Hum Genet       Date:  2015-12-10       Impact factor: 3.172

2.  A commentary on comparison of the performance of Ion Torrent chips in noninvasive prenatal trisomy detection.

Authors:  Osamu Samura
Journal:  J Hum Genet       Date:  2014-07-03       Impact factor: 3.172

3.  Evaluation of two highly-multiplexed custom panels for massively parallel semiconductor sequencing on paraffin DNA.

Authors:  Vassiliki Kotoula; Aggeliki Lyberopoulou; Kyriaki Papadopoulou; Elpida Charalambous; Zoi Alexopoulou; Chryssa Gakou; Sotiris Lakis; Eleftheria Tsolaki; Konstantinos Lilakos; George Fountzilas
Journal:  PLoS One       Date:  2015-06-03       Impact factor: 3.240

4.  Advances and Applications of Ion Torrent Personal Genome Machine in Cutaneous Squamous Cell Carcinoma Reveal Novel Gene Mutations.

Authors:  Yu-Ping Hsiao; Chun-Te Lu; Ju Chang-Chien; Wan-Ru Chao; Jiann-Jou Yang
Journal:  Materials (Basel)       Date:  2016-06-14       Impact factor: 3.623

5.  Utilization of Benchtop Next Generation Sequencing Platforms Ion Torrent PGM and MiSeq in Noninvasive Prenatal Testing for Chromosome 21 Trisomy and Testing of Impact of In Silico and Physical Size Selection on Its Analytical Performance.

Authors:  Gabriel Minarik; Gabriela Repiska; Michaela Hyblova; Emilia Nagyova; Katarina Soltys; Jaroslav Budis; Frantisek Duris; Rastislav Sysak; Maria Gerykova Bujalkova; Barbora Vlkova-Izrael; Orsolya Biro; Balint Nagy; Tomas Szemes
Journal:  PLoS One       Date:  2015-12-15       Impact factor: 3.240

6.  Comparison of two high-throughput semiconductor chip sequencing platforms in noninvasive prenatal testing for Down syndrome in early pregnancy.

Authors:  Sunshin Kim; HeeJung Jung; Sung Hee Han; SeungJae Lee; JeongSub Kwon; Min Gyun Kim; Hyungsik Chu; Hongliang Chen; Kyudong Han; Hwanjong Kwak; Sunghoon Park; Hee Jae Joo; Byung Chul Kim; Jong Bhak
Journal:  BMC Med Genomics       Date:  2016-04-30       Impact factor: 3.063

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.