Literature DB >> 24918958

Black-blood multicontrast imaging of carotid arteries with DANTE-prepared 2D and 3D MR imaging.

Linqing Li1, Joshua T Chai, Luca Biasiolli, Matthew D Robson, Robin P Choudhury, Ashok I Handa, Jamie Near, Peter Jezzard.   

Abstract

PURPOSE: To prospectively compare the black-blood ( BB black blood ) imaging efficiency of a delay alternating with nutation for tailored excitation ( DANTE delay alternating with nutation for tailored excitation ) preparation module with conventional double inversion-recovery ( DIR double inversion recovery ) and motion-sensitive driven equilibrium ( MSDE motion-sensitive driven equilibrium ) preparation modules and to introduce a new three-dimensional ( 3D three-dimensional ) T1-weighted magnetic resonance (MR) imaging sequence.
MATERIALS AND METHODS: Carotid artery wall imaging was performed in 10 healthy volunteers and 15 patients in accordance with an institutional review board-approved protocol. Two-dimensional ( 2D two-dimensional ) turbo spin-echo ( TSE turbo spin echo ) and 3D three-dimensional fast low-angle shot ( FLASH fast low-angle shot ) sequences served as readout modules. DANTE delay alternating with nutation for tailored excitation -prepared T1-, T2-, and proton density-weighted 2D two-dimensional TSE turbo spin echo images, as well as T1-weighted 3D three-dimensional DANTE delay alternating with nutation for tailored excitation -prepared FLASH fast low-angle shot (hereafter, 3D three-dimensional DASH DANTE-prepared FLASH ) images, were acquired in the region of the carotid artery bifurcation. For comparison, 2D two-dimensional DIR double inversion recovery -prepared, 2D two-dimensional MSDE motion-sensitive driven equilibrium -prepared multicontrast TSE turbo spin echo , and 3D three-dimensional MSDE motion-sensitive driven equilibrium -prepared FLASH fast low-angle shot (hereafter, 3D three-dimensional MERGE MSDE-prepared FLASH ) MR images were also acquired. The effective contrast-to-noise ratio ( CNReff effective contrast-to-noise ratio ) per unit time was calculated for all sequences. Paired t tests were performed to test within-group differences in vessel wall CNReff effective contrast-to-noise ratio .
RESULTS: The CNReff effective contrast-to-noise ratio of DANTE delay alternating with nutation for tailored excitation -prepared T1-, T2-, and proton density-weighted sequences was 27.3, 14.7, and 25.7 mm(-1)min(-1/2), respectively; this represented an improvement of approximately 25%-100% (P < .05) when compared with the CNReff effective contrast-to-noise ratio attained with existing methods. The 3D three-dimensional DASH DANTE-prepared FLASH technique proved to be a fast (<2 seconds per section) and high-spatial-resolution (0.6 mm isotropic) BB black blood technique with higher (75%-100% improvement, P < .001) signal-to-noise ratio efficiency than the 3D three-dimensional MERGE MSDE-prepared FLASH technique.
CONCLUSION: The DANTE delay alternating with nutation for tailored excitation -prepared multicontrast 2D two-dimensional BB black blood technique is a promising new tool for MR imaging of carotid artery walls. Additionally, the 3D three-dimensional DASH DANTE-prepared FLASH sequence enables 3D three-dimensional high-spatial-resolution fast T1-weighted imaging of carotid artery walls. ©RSNA, 2014 Online supplemental material is available for this article .

Entities:  

Mesh:

Year:  2014        PMID: 24918958     DOI: 10.1148/radiol.14131717

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  31 in total

1.  Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

Authors:  Yibin Xie; Qi Yang; Guoxi Xie; Jianing Pang; Zhaoyang Fan; Debiao Li
Journal:  Magn Reson Med       Date:  2015-07-08       Impact factor: 4.668

2.  Cerebral Venous Thrombosis: MR Black-Blood Thrombus Imaging with Enhanced Blood Signal Suppression.

Authors:  G Wang; X Yang; J Duan; N Zhang; M M Maya; Y Xie; X Bi; X Ji; D Li; Q Yang; Z Fan
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-26       Impact factor: 3.825

3.  Assessment of quantitative methods for enhancement measurement on vessel wall magnetic resonance imaging evaluation of intracranial atherosclerosis.

Authors:  Matthew D Alexander; Adam de Havenon; Seong-Eun Kim; Dennis L Parker; Joseph S McNally
Journal:  Neuroradiology       Date:  2019-01-24       Impact factor: 2.804

4.  Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus.

Authors:  Chengcheng Zhu; Henrik Haraldsson; Farshid Faraji; Christopher Owens; Warren Gasper; Sinyeob Ahn; Jing Liu; Gerhard Laub; Michael D Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2015-10-22       Impact factor: 2.546

5.  A novel approach to probing in vivo metabolite relaxation: Linear quantification of spatially modulated magnetization.

Authors:  Linqing Li; Ningzhi Li; Li An; Jun Shen
Journal:  Magn Reson Med       Date:  2017-09-23       Impact factor: 4.668

6.  DANTE-prepared three-dimensional FLASH: A fast isotropic-resolution MR approach to morphological evaluation of the peripheral arterial wall at 3 Tesla.

Authors:  Guoxi Xie; Nan Zhang; Yibin Xie; Christopher Nguyen; Zixin Deng; Xiaoming Bi; Zhanming Fan; Xin Liu; Debiao Li; Zhaoyang Fan
Journal:  J Magn Reson Imaging       Date:  2015-07-02       Impact factor: 4.813

7.  Effect of Time Elapsed since Gadolinium Administration on Atherosclerotic Plaque Enhancement in Clinical Vessel Wall MR Imaging Studies.

Authors:  A de Havenon; H J Muhina; D L Parker; J S McNally; M D Alexander
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-12       Impact factor: 3.825

8.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

9.  Joint intracranial and carotid vessel wall imaging in 5 minutes using compressed sensing accelerated DANTE-SPACE.

Authors:  Sen Jia; Lei Zhang; Lijie Ren; Yulong Qi; Jinhao Ly; Na Zhang; Ye Li; Xin Liu; Hairong Zheng; Dong Liang; Yiu-Cho Chung
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

Review 10.  Three-Dimensional Carotid Plaque MR Imaging.

Authors:  Chun Yuan; Dennis L Parker
Journal:  Neuroimaging Clin N Am       Date:  2015-10-19       Impact factor: 2.264

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.