Literature DB >> 24916429

Transfemoral liver biopsy using a Quick-Core biopsy needle system in living donor liver transplantation recipients.

Fen Qiang Li1, Gi-Young Ko, Kyu-Bo Sung, Dong-Il Gwon, Heung Kyu Ko, Jong Woo Kim, Eunsil Yu.   

Abstract

The purpose of this study was to evaluate the efficacy and safety of transfemoral liver biopsy with a Quick-Core biopsy needle in select living donor liver transplantation (LDLT) recipients. Eight LDLT recipients underwent 9 transfemoral liver biopsy sessions. Six patients had undergone modified right lobe (mRL) LDLT, and 2 patients had undergone dual-left lobe LDLT. The indications for transfemoral liver biopsy were a hepatic vein (HV) at an acute angle to the inferior vena cava (IVC) on the coronal plane and a thin (<10-mm) liver parenchyma surrounding the HV to be biopsied on enhanced computed tomography. Under fluoroscopic guidance, the right inferior HV in the mRL or the left HV in the right-sided left lobe with a cranial orientation was negotiated with a 5-Fr catheter via the common femoral vein. Then, a stiffening cannula was introduced into the HV over a stiff guide wire. Needle passage was then performed with an 18- or 19-gauge Quick-Core biopsy needle. Technical success was achieved in all sessions without major complications. The median number of needle passages was 4 (range = 2-6). The median total length of obtained liver specimens in each session was 44 mm (range = 24-75 mm). The median number of portal tracts was 18 (range = 10-29), and the obtained liver specimens were adequate for histological diagnosis in all sessions. In conclusion, transfemoral liver biopsy with a Quick-Core biopsy needle is an effective and safe alternative for obtaining a liver specimen when standard transjugular liver biopsy is not feasible because of an unfavorable HV angle with respect to the IVC and/or a thin liver parenchyma surrounding the HV.
© 2014 American Association for the Study of Liver Diseases.

Entities:  

Mesh:

Year:  2014        PMID: 24916429     DOI: 10.1002/lt.23928

Source DB:  PubMed          Journal:  Liver Transpl        ISSN: 1527-6465            Impact factor:   5.799


  3 in total

1.  A successful case of liver biopsy via the right femoral vein using the Quick-Core biopsy needle.

Authors:  Kenkichi Michimoto; Kanichiro Shimizu; Yoshihiko Kameoka; Naoki Kurata; Tadashi Tokashiki; Shunichi Sadaoka; Kunihiko Fukuda
Journal:  Jpn J Radiol       Date:  2015-03-17       Impact factor: 2.374

2.  Asian-Pacific Association for the Study of the Liver (APASL) consensus guidelines on invasive and non-invasive assessment of hepatic fibrosis: a 2016 update.

Authors:  Gamal Shiha; Alaa Ibrahim; Ahmed Helmy; Shiv Kumar Sarin; Masao Omata; Ashish Kumar; David Bernstien; Hitushi Maruyama; Vivek Saraswat; Yogesh Chawla; Saeed Hamid; Zaigham Abbas; Pierre Bedossa; Puja Sakhuja; Mamun Elmahatab; Seng Gee Lim; Laurentius Lesmana; Jose Sollano; Ji-Dong Jia; Bahaa Abbas; Ashraf Omar; Barjesh Sharma; Diana Payawal; Ahmed Abdallah; Abdelhamid Serwah; Abdelkhalek Hamed; Aly Elsayed; Amany AbdelMaqsod; Tarek Hassanein; Ahmed Ihab; Hamsik GHaziuan; Nizar Zein; Manoj Kumar
Journal:  Hepatol Int       Date:  2016-10-06       Impact factor: 6.047

Review 3.  Indian College of Radiology and Imaging Evidence-Based Guidelines for Interventions in Portal Hypertension and Its Complications.

Authors:  Amar Mukund; Shaleen Rana; Chander Mohan; Naveen Kalra; Sanjay Saran Baijal
Journal:  Indian J Radiol Imaging       Date:  2022-01-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.