Literature DB >> 24910246

A study on correlation between 2D and 3D gamma evaluation metrics in patient-specific quality assurance for VMAT.

Dhanabalan Rajasekaran1, Prakash Jeevanandam2, Prabakar Sukumar2, Arulpandiyan Ranganathan2, Samdevakumar Johnjothi2, Vivekanandan Nagarajan2.   

Abstract

In this study, we investigated the correlation between 2-dimensional (2D) and 3D gamma analysis using the new PTW OCTAVIUS 4D system for various parameters. For this study, we selected 150 clinically approved volumetric-modulated arc therapy (VMAT) plans of head and neck (50), thoracic (esophagus) (50), and pelvic (cervix) (50) sites. Individual verification plans were created and delivered to the OCTAVIUS 4D phantom. Measured and calculated dose distributions were compared using the 2D and 3D gamma analysis by global (maximum), local and selected (isocenter) dose methods. The average gamma passing rate for 2D global gamma analysis in coronal and sagittal plane was 94.81% ± 2.12% and 95.19% ± 1.76%, respectively, for commonly used 3-mm/3% criteria with 10% low-dose threshold. Correspondingly, for the same criteria, the average gamma passing rate for 3D planar global gamma analysis was 95.90% ± 1.57% and 95.61% ± 1.65%. The volumetric 3D gamma passing rate for 3-mm/3% (10% low-dose threshold) global gamma was 96.49% ± 1.49%. Applying stringent gamma criteria resulted in higher differences between 2D planar and 3D planar gamma analysis across all the global, local, and selected dose gamma evaluation methods. The average gamma passing rate for volumetric 3D gamma analysis was 1.49%, 1.36%, and 2.16% higher when compared with 2D planar analyses (coronal and sagittal combined average) for 3mm/3% global, local, and selected dose gamma analysis, respectively. On the basis of the wide range of analysis and correlation study, we conclude that there is no assured correlation or notable pattern that could provide relation between planar 2D and volumetric 3D gamma analysis. Owing to higher passing rates, higher action limits can be set while performing 3D quality assurance. Site-wise action limits may be considered for patient-specific QA in VMAT.
Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D Dosimetry; Dose verification; OCTAVIUS 4D system; VMAT QA

Mesh:

Year:  2014        PMID: 24910246     DOI: 10.1016/j.meddos.2014.05.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  9 in total

1.  A patient-specific QA comparison between 2D and 3D diode arrays for single-lesion SRS and SBRT treatments.

Authors:  Yongsook C Lee; Yongbok Kim
Journal:  J Radiosurg SBRT       Date:  2021

2.  Gamma analysis dependence on specified low-dose thresholds for VMAT QA.

Authors:  Ji-Hye Song; Min-Joo Kim; So-Hyun Park; Seu-Ran Lee; Min-Young Lee; Dong Soo Lee; Tae Suk Suh
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

3.  Prediction of VMAT delivery accuracy with textural features calculated from fluence maps.

Authors:  Jong Min Park; Jung-In Kim; So-Yeon Park
Journal:  Radiat Oncol       Date:  2019-12-23       Impact factor: 3.481

4.  Evaluation of Delta4DVH Anatomy in 3D Patient-Specific IMRT Quality Assurance.

Authors:  Du Tang; Zhen Yang; Xunzhang Dai; Ying Cao
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec

5.  Model refinement increases confidence levels and clinical agreement when commissioning a three-dimensional secondary dose calculation system.

Authors:  Brian Bismack; Jennifer Dolan; Eric Laugeman; Anant Gopal; Ning Wen; Indrin Chetty
Journal:  J Appl Clin Med Phys       Date:  2022-04-07       Impact factor: 2.243

6.  Correlation analysis between 2D and quasi-3D gamma evaluations for both intensity-modulated radiation therapy and volumetric modulated arc therapy.

Authors:  Jung-In Kim; Chang Heon Choi; Hong-Gyun Wu; Jin Ho Kim; Kyubo Kim; Jong Min Park
Journal:  Oncotarget       Date:  2017-01-17

7.  Gamma analysis with a gamma criterion of 2%/1 mm for stereotactic ablative radiotherapy delivered with volumetric modulated arc therapy technique: a single institution experience.

Authors:  Jung-In Kim; Minsoo Chun; Hong-Gyun Wu; Eui Kyu Chie; Hak Jae Kim; Jin Ho Kim; Jong Min Park
Journal:  Oncotarget       Date:  2017-06-16

8.  Practical application of Octavius® -4D: Characteristics and criticalities for IMRT and VMAT verification.

Authors:  Patrizia Urso; Rita Lorusso; Luca Marzoli; Daniela Corletto; Paolo Imperiale; Annalisa Pepe; Lorenzo Bianchi
Journal:  J Appl Clin Med Phys       Date:  2018-07-16       Impact factor: 2.102

9.  Improvement in sensitivity of radiochromic 3D dosimeter based on rigid polyurethane resin by incorporating tartrazine.

Authors:  Jin Dong Cho; Jaeman Son; Chang Heon Choi; Jin Sung Kim; Hong-Gyun Wu; Jong Min Park; Jung-In Kim
Journal:  PLoS One       Date:  2020-03-16       Impact factor: 3.240

  9 in total