Literature DB >> 24908367

Diffusion tensor imaging of the sural nerve in normal controls.

Boklye Kim1, Ashok Srinivasan2, Brian Sabb3, Eva L Feldman4, Rodica Pop-Busui5.   

Abstract

OBJECTIVE: To develop a diffusion tensor imaging (DTI) protocol for assessing the sural nerve in healthy subjects.
METHODS: Sural nerves in 25 controls were imaged using DTI at 3T with 6, 15, and 32 gradient directions. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were computed from nerve regions of interest co-registered with T2-weighted images.
RESULTS: Coronal images with 0.5(RL)× 2.0(FH)× 0.5(AP)mm(3) resolution successfully localized the sural nerve. FA maps showed less variability with 32 directions (0.559 ± 0.071) compared to 15(0.590 ± 0.080) and 6(0.659 ± 0.109).
CONCLUSIONS: Our DTI protocol was effective in imaging sural nerves in controls to establish normative FA/ADC, with potential to be used non-invasively in diseased nerves of patients.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Diffusion tensor imaging; Fractional anisotropy; Image registration; Sural nerve

Mesh:

Year:  2014        PMID: 24908367      PMCID: PMC5084621          DOI: 10.1016/j.clinimag.2014.04.008

Source DB:  PubMed          Journal:  Clin Imaging        ISSN: 0899-7071            Impact factor:   1.605


  40 in total

Review 1.  MR neurography: diagnostic utility in the surgical treatment of peripheral nerve disorders.

Authors:  Gerald A Grant; Robert Goodkin; Kenneth R Maravilla; Michel Kliot
Journal:  Neuroimaging Clin N Am       Date:  2004-02       Impact factor: 2.264

2.  The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study.

Authors:  Derek K Jones
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

3.  Visualization of cervical nerve roots and their distal nerve fibers by diffusion-weighted scanning using parallel imaging.

Authors:  K Tsuchiya; A Fujikawa; H Tateishi; T Nitatori
Journal:  Acta Radiol       Date:  2006-07       Impact factor: 1.990

4.  Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T.

Authors:  Jonathan A D Farrell; Bennett A Landman; Craig K Jones; Seth A Smith; Jerry L Prince; Peter C M van Zijl; Susumu Mori
Journal:  J Magn Reson Imaging       Date:  2007-09       Impact factor: 4.813

Review 5.  Diffusion-tensor imaging of small nerve bundles: cranial nerves, peripheral nerves, distal spinal cord, and lumbar nerve roots--clinical applications.

Authors:  Keith A Cauley; Christopher G Filippi
Journal:  AJR Am J Roentgenol       Date:  2013-08       Impact factor: 3.959

6.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

Authors:  C R Meyer; J L Boes; B Kim; P H Bland; K R Zasadny; P V Kison; K Koral; K A Frey; R L Wahl
Journal:  Med Image Anal       Date:  1997-04       Impact factor: 8.545

7.  Distribution characteristics, reproducibility, and precision of region of interest-based hippocampal diffusion tensor imaging measures.

Authors:  M J Müller; M Mazanek; C Weibrich; P R Dellani; P Stoeter; A Fellgiebel
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

8.  Diffusion tensor imaging and tractography of median nerve: normative diffusion values.

Authors:  Neslihan Kabakci; Bengi Gürses; Zeynep Firat; Ali Bayram; Aziz Müfit Uluğ; Arzu Kovanlikaya; Ilhami Kovanlikaya
Journal:  AJR Am J Roentgenol       Date:  2007-10       Impact factor: 3.959

9.  Diffusion tensor imaging and tractography of the median nerve in carpal tunnel syndrome: preliminary results.

Authors:  C Khalil; C Hancart; V Le Thuc; C Chantelot; D Chechin; A Cotten
Journal:  Eur Radiol       Date:  2008-04-17       Impact factor: 5.315

Review 10.  Psychological aspects of diabetic neuropathic foot complications: an overview.

Authors:  Loretta Vileikyte; Richard R Rubin; Howard Leventhal
Journal:  Diabetes Metab Res Rev       Date:  2004 May-Jun       Impact factor: 4.876

View more
  2 in total

1.  Acute radial nerve entrapment at the spiral groove: detection by DTI-based neurography.

Authors:  Suren Jengojan; Florian Kovar; Julia Breitenseher; Michael Weber; Daniela Prayer; Gregor Kasprian
Journal:  Eur Radiol       Date:  2015-01-11       Impact factor: 5.315

2.  Diffusion tensor imaging and tractography of the sciatic and femoral nerves in healthy volunteers at 3T.

Authors:  Yasushi Wako; Junichi Nakamura; Yawara Eguchi; Shigeo Hagiwara; Michiaki Miura; Yuya Kawarai; Masahiko Sugano; Kento Nawata; Kensuke Yoshino; Yasunari Toguchi; Yoshitada Masuda; Koji Matsumoto; Takane Suzuki; Sumihisa Orita; Seiji Ohtori
Journal:  J Orthop Surg Res       Date:  2017-11-29       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.