| Literature DB >> 24904752 |
Mohammad Reza Monazzam1, Monireh Hosseini2, Laleh Farhang Matin3, Habib Allah Aghaei4, Hossein Khosroabadi5, Ahmad Hesami5.
Abstract
BACKGROUND: Advances in science and technology of electrical equipment, despite increasing human welfare in everyday life, have increased the number of people exposed to Electro-Magnetic Fields (EMFs). Because of possible adverse effects on the health of exposed individuals, the EMFs have being the center of attention. This study was performed to determine possible correlation between Extremely Low Frequency Electro-Magnetic Fields (ELF EMFs) and sleep quality and public health of those working in substation units of a petrochemical complex in southern Iran. MATERIALS ANDEntities:
Keywords: ELF; Electromagnetic fields; General health; Quality of sleep
Year: 2014 PMID: 24904752 PMCID: PMC4045979 DOI: 10.1186/2052-336X-12-78
Source DB: PubMed Journal: J Environ Health Sci Eng
Job title and characteristics of workers
| Ethylene substation | Engineer | 4 | Bachelor |
| | Technician | 4 | Associated diploma |
| | Worker | 1 | Diploma |
| Boiler substation | Engineer | 2 | Bachelor |
| | Site man | 3 | Associated diploma |
| | Operator | 4 | Diploma |
| | Operator | 16 | Bachelor |
| Engineer | 6 | Bachelor |
The results of the questionnaires by the control and case groups
| Control room | Operator | 2.87 | 9.5 | 0.14 | |
| Engineering room | Engineers | 1.83 | 5.5 | 0.05 | |
| Ethylene substation | Engineer | 14.33 | 31.5 | 40.43 | |
| Technician | 4.75 | 16.75 | |||
| Worker | 4 | 7 | |||
| Boiler substation | Engineer | 12.5 | 20 | 49.90 | |
| Site man | 9 | 23 | |||
| Site operator | 5.5 | 12.25 |
Comparison of the control and case groups in terms of sleep quality and general health
| Sleep quality | Case | 9.25 | 20.51 | 4.53 |
| Control | 2.63 | 1.13 | 1.06 | |
| General health | Case | 7.50 | 11.14 | 3.34 |
| Control | 20.70 | 77.17 | 8.78 |
Results of the overall evaluation of data by -test
| Variance of the difference between the means | 1.1663 | 10.3937 |
| Standard deviation of the differences | 1.0799 | 3.2239 |
| t’ value | −6.1346 | −4.0944 |
| Probability of t’ | 0.0000 | 0.0004 |
Results of Duncan method
| Engineers of Ethylene Unit | 14.25 | a | Engineers of Ethylene Unit | 31.50 | a |
| Engineers of Boiler Unit | 12.75 | ab | Site man of Boiler Unit | 23.00 | b |
| Site man of Boiler Unit | 9.00 | bc | Engineers of Boiler Unit | 20.00 | bc |
| Operator of Boiler Unit | 5.50 | cd | Technician of Ethylene Unit | 16.75 | c |
| Technician of Ethylene Unit | 4.75 | cd | Operator of Boiler Unit | 12.25 | d |
| Worker of Ethylene Unit | 4.00 | d | Operator of Control Room | 9.50 | de |
| Operator of Control Room | 3.00 | d | Worker of Ethylene Unit | 7.00 | e |
| Engineers of Engineering Room | 2.25 | d | Engineers of Engineering Room | 5.50 | e |