Literature DB >> 24899233

Nobori biolimus-eluting stent vs. permanent polymer drug-eluting stents in patients undergoing percutaneous coronary intervention.

Gian Battista Danzi1, Raffaele Piccolo, Gennaro Galasso, Federico Piscione.   

Abstract

BACKGROUND: Permanent polymer coatings on drug-eluting stents (DES) surface have been identified as triggers of adverse events following percutaneous coronary intervention (PCI). However, efficacy and safety data for the Nobori biolimus-eluting stent (BES), a biodegradable polymer DES, are limited, so the aim of this study was to evaluate clinical outcomes associated with the Nobori BES compared with permanent polymer DES in patients undergoing PCI. METHODS AND
RESULTS: Randomized trials comparing Nobori BES vs. other DES were included in the meta-analysis. The 12-month clinical endpoints were: target lesion revascularization (TLR), all-cause mortality, myocardial infarction (MI) and stent thrombosis (ST). Seven trials totaling 12,090 PCI patients met the inclusion criteria. Nobori BES vs. other DES had a comparable risk of TLR (odds ratio [OR] 0.94; 95% confidence interval [CI], 0.66-1.34; P=0.74), mortality (OR 1.00; 95% CI, 0.78-1.28; P=0.98), MI (OR 1.10; 95% CI, 0.87-1.40; P=0.42) and definite/probable ST (OR 1.01; 95% CI, 0.45-2.25; P=0.99). Despite Nobori BES showing similar clinical results to sirolimus-, everolimus- and zotarolimus-eluting stents, it was superior to paclitaxel-eluting stents in reducing the risk of TLR (OR 0.31; 95% CI, 0.10-0.90; P=0.03)
CONCLUSIONS: Nobori BES use is associated with a similar safety and efficacy as permanent polymer DES at 1-year follow-up, albeit it is superior to paclitaxel-eluting stents in terms of TLR. Long-term follow-up data are needed in order to establish whether polymer degradation related to Nobori BES implantation improves clinical outcomes.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24899233     DOI: 10.1253/circj.cj-13-1558

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  4 in total

Review 1.  The Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence.

Authors:  Alberto Chisari; Anna Maria Pistritto; Raffaele Piccolo; Alessio La Manna; Gian Battista Danzi
Journal:  Int J Mol Sci       Date:  2016-09-06       Impact factor: 5.923

2.  Comparison of 9-Month Angiographic Follow-Up and Long-Term Clinical Outcomes of Biodegradable Polymer Drug-Eluting Stents and Second-Generation Durable Polymer Drug-Eluting Stents in Patients Undergoing Single Coronary Artery Stenting.

Authors:  Ming-Lung Tsai; Ming-Jer Hsieh; Chun-Chi Chen; Shang-Hung Chang; Chao-Yung Wang; Dong-Yi Chen; Chia-Hung Yang; Jih-Kai Yeh; Ming-Yun Ho; I-Chang Hsieh
Journal:  Acta Cardiol Sin       Date:  2020-03       Impact factor: 2.672

3.  Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable-Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularization: 2-Year Results of the BIOSCIENCE Trial.

Authors:  Rainer Zbinden; Raffaele Piccolo; Dik Heg; Marco Roffi; David J Kurz; Olivier Muller; André Vuilliomenet; Stéphane Cook; Daniel Weilenmann; Christoph Kaiser; Peiman Jamshidi; Anna Franzone; Franz Eberli; Peter Jüni; Stephan Windecker; Thomas Pilgrim
Journal:  J Am Heart Assoc       Date:  2016-03-15       Impact factor: 5.501

4.  A comparison of the main outcomes from BP-BES and DP-DES at five years of follow-up: A systematic review and meta-analysis.

Authors:  Pan Lu; Shuai Lu; Yuanyuan Li; Mengmeng Deng; Zhaohui Wang; Xiaobo Mao
Journal:  Sci Rep       Date:  2017-11-03       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.