Literature DB >> 24897887

Test-retest reliability of the Bod Pod: the effect of multiple assessments.

Larry A Tucker, James D Lecheminant, Bruce W Bailey.   

Abstract

The Bod Pod uses air-displacement plethysmography to estimate body fat percentage (BF%). This study was designed to assess the test-retest reliability of the Bod Pod. The study included 283 women (M age = 41.0 yr., SD = 3.0). Each participant was tested at least twice in the Bod Pod. Results showed no significant mean difference between the test and the retest. The intraclass correlation coefficient (ICC) was .991. However, the absolute value of the initial trial differences (absolute mean difference) was .96 (SD = .90). A third assessment of BF% was taken when the initial trial difference was greater than 1 percentage point, and the two closest values were compared. This strategy resulted in a significant decrease in the absolute mean difference, from .96 to .55 percentage point, and ICC increased to .998. The Bod Pod appears to measure body fat percentage reliably; however, findings suggest that multiple trials may be necessary to detect small treatment effects.

Entities:  

Mesh:

Year:  2014        PMID: 24897887     DOI: 10.2466/03.PMS.118k15w5

Source DB:  PubMed          Journal:  Percept Mot Skills        ISSN: 0031-5125


  10 in total

1.  Reliability of Multifrequency Bioelectrical Impedance Analysis to Quantify Body Composition in Patients After Musculoskeletal Trauma.

Authors:  Brandon Koch; Aspen Miller; Natalie A Glass; Erin Owen; Tessa Kirkpatrick; Ruth Grossman; Steven M Leary; John Davison; Michael C Willey
Journal:  Iowa Orthop J       Date:  2022-06

2.  Dairy consumption and insulin resistance: the role of body fat, physical activity, and energy intake.

Authors:  Larry A Tucker; Andrea Erickson; James D LeCheminant; Bruce W Bailey
Journal:  J Diabetes Res       Date:  2015-01-29       Impact factor: 4.011

3.  Air displacement plethysmography versus dual-energy x-ray absorptiometry in underweight, normal-weight, and overweight/obese individuals.

Authors:  David W Lowry; A Janet Tomiyama
Journal:  PLoS One       Date:  2015-01-21       Impact factor: 3.240

4.  Preserved Fat-Free Mass after Gastric Bypass and Duodenal Switch.

Authors:  Martin Skogar; Ulf Holmbäck; Jakob Hedberg; Ulf Risérus; Magnus Sundbom
Journal:  Obes Surg       Date:  2017-07       Impact factor: 4.129

5.  Measurement agreement in percent body fat estimates among laboratory and field assessments in college students: Use of equivalence testing.

Authors:  Ryan D Burns; You Fu; Nora Constantino
Journal:  PLoS One       Date:  2019-03-20       Impact factor: 3.240

6.  Modeling Risk Factors for Sleep- and Adiposity-Related Cardiometabolic Disease: Protocol for the Short Sleep Undermines Cardiometabolic Health (SLUMBRx) Observational Study.

Authors:  John C Higginbotham; Michael A Grandner; John P Allegrante; Adam P Knowlden
Journal:  JMIR Res Protoc       Date:  2021-03-09

7.  The impact of subject positioning on body composition assessments by air displacement plethysmography evaluated in a heterogeneous sample.

Authors:  Raluca Horhat; Monica Miclos-Balica; Paul Muntean; Sandra Popa; Irina Sima; Bogdan Glisici; Onisim Cîrja; Adrian Neagu; Monica Neagu
Journal:  PLoS One       Date:  2022-04-15       Impact factor: 3.240

8.  Meat Intake and Insulin Resistance in Women without Type 2 Diabetes.

Authors:  Larry A Tucker; James D LeCheminant; Bruce W Bailey
Journal:  J Diabetes Res       Date:  2015-07-09       Impact factor: 4.011

9.  A Comparison of Body Composition Across Two Phases of the Menstrual Cycle Utilizing Dual-Energy X-Ray Absorptiometry, Air Displacement Plethysmography, and Bioelectrical Impedance Analysis.

Authors:  Courtenay S Hicks; Cherilyn N McLester; Tiffany A Esmat; John R McLester
Journal:  Int J Exerc Sci       Date:  2017-12-01

10.  Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.

Authors:  Carolin Adler; Astrid Steinbrecher; Lina Jaeschke; Anja Mähler; Michael Boschmann; Stephanie Jeran; Tobias Pischon
Journal:  PLoS One       Date:  2017-07-03       Impact factor: 3.240

  10 in total