Literature DB >> 24897400

European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

Magdalena Krintus, Marek Kozinski, Pascal Boudry, Nuria Estañ Capell, Ursula Köller, Karl Lackner, Guillaume Lefèvre, Lieselotte Lennartz, Johannes Lotz, Antonio Mora Herranz, Mads Nybo, Mario Plebani, Maria B Sandberg, Wolfgang Schratzberger, Jessie Shih, Øyvind Skadberg, Ahmed Taoufik Chargui, Martina Zaninotto, Grazyna Sypniewska.   

Abstract

BACKGROUND: International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL).
METHODS: Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study.
RESULTS: Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent.
CONCLUSIONS: The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24897400     DOI: 10.1515/cclm-2014-0107

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  21 in total

1.  B-Type Natriuretic Peptide and Cardiac Troponin I Are Associated With Adverse Outcomes in Stable Kidney Transplant Recipients.

Authors:  Petr Jarolim; Brian L Claggett; Michael J Conrad; Myra A Carpenter; Anastasia Ivanova; Andrew G Bostom; John W Kusek; Lawrence G Hunsicker; Paul F Jacques; Lisa Gravens-Mueller; Peter Finn; Scott D Solomon; Daniel E Weiner; Andrew S Levey; Marc A Pfeffer
Journal:  Transplantation       Date:  2017-01       Impact factor: 4.939

2.  Early diagnosis of acute myocardial infarction in patients with mild elevations of cardiac troponin.

Authors:  Jasper Boeddinghaus; Tobias Reichlin; Thomas Nestelberger; Raphael Twerenbold; Yvette Meili; Karin Wildi; Petra Hillinger; Maria Rubini Giménez; Janosch Cupa; Lukas Schumacher; Marie Schubera; Patrick Badertscher; Sydney Corbière; Karin Grimm; Christian Puelacher; Zaid Sabti; Dayana Flores Widmer; Nicolas Schaerli; Nikola Kozhuharov; Samyut Shrestha; Tobias Bürge; Patrick Mächler; Michael Büchi; Katharina Rentsch; Òscar Miró; Beatriz López; F Javier Martin-Sanchez; Esther Rodriguez-Adrada; Beata Morawiec; Damian Kawecki; Eva Ganovská; Jiri Parenica; Jens Lohrmann; Andreas Buser; Dagmar I Keller; Stefan Osswald; Christian Mueller
Journal:  Clin Res Cardiol       Date:  2017-02-01       Impact factor: 5.460

Review 3.  High-sensitivity assays for troponin in patients with cardiac disease.

Authors:  Dirk Westermann; Johannes Tobias Neumann; Nils Arne Sörensen; Stefan Blankenberg
Journal:  Nat Rev Cardiol       Date:  2017-04-06       Impact factor: 32.419

4.  High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy: A Prospective, Observational Cohort Study.

Authors:  Andreas Duma; Swatilika Pal; Joshua Johnston; Mohammad A Helwani; Adithya Bhat; Bali Gill; Jessica Rosenkvist; Christopher Cartmill; Frank Brown; J Philip Miller; Mitchell G Scott; Francisco Sanchez-Conde; Michael Jarvis; Nuri B Farber; Charles F Zorumski; Charles Conway; Peter Nagele
Journal:  Anesthesiology       Date:  2017-04       Impact factor: 7.892

5.  Are high-sensitivity cardiac troponin I values stable between preoperative visit and day of non-cardiac surgery?

Authors:  Eslam Samaha; Mohammad A Helwani; Jamie C Brown; Frank Brown; Allan S Jaffe; Mitchell G Scott; Peter Nagele
Journal:  Clin Biochem       Date:  2017-11-22       Impact factor: 3.281

6.  The impact of an acute chest pain pathway on the investigation and management of cardiac chest pain.

Authors:  Mark Sweeney; Gillian Bleeze; Sarah Storey; Alexander Cairns; Alexander Taylor; Catherine Holmes; Steve Hart; Nick Lawrance; William G Oldfield; Christopher S Baker
Journal:  Future Healthc J       Date:  2020-02

7.  High-sensitivity troponins in dialysis patients: variation and prognostic value.

Authors:  Sunna Snaedal; Peter Bárány; Sigrún H Lund; Abdul R Qureshi; Olof Heimbürger; Peter Stenvinkel; Christian Löwbeer; Karolina Szummer
Journal:  Clin Kidney J       Date:  2020-12-12

8.  Serum Cardiac Troponin-I is Superior to Troponin-T as a Marker for Left Ventricular Dysfunction in Clinically Stable Patients with End-Stage Renal Disease.

Authors:  Maurits S Buiten; Mihály K de Bie; Joris I Rotmans; Friedo W Dekker; Marjolijn van Buren; Ton J Rabelink; Christa M Cobbaert; Martin J Schalij; Arnoud van der Laarse; J Wouter Jukema
Journal:  PLoS One       Date:  2015-08-03       Impact factor: 3.240

9.  High-sensitivity troponin I concentrations are a marker of an advanced hypertrophic response and adverse outcomes in patients with aortic stenosis.

Authors:  Calvin W L Chin; Anoop S V Shah; David A McAllister; S Joanna Cowell; Shirjel Alam; Jeremy P Langrish; Fiona E Strachan; Amanda L Hunter; Anna Maria Choy; Chim C Lang; Simon Walker; Nicholas A Boon; David E Newby; Nicholas L Mills; Marc R Dweck
Journal:  Eur Heart J       Date:  2014-05-14       Impact factor: 29.983

10.  Heart Fatty Acid Binding Protein and cardiac troponin: development of an optimal rule-out strategy for acute myocardial infarction.

Authors:  Joanna M Young; John W Pickering; Peter M George; Sally J Aldous; John Wallace; Chris M Frampton; Richard W Troughton; Mark A Richards; Jaimi H Greenslade; Louise Cullen; Martin P Than
Journal:  BMC Emerg Med       Date:  2016-08-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.