Literature DB >> 24895072

An evaluation of two conducted electrical weapons using a swine comparative cardiac safety model.

Donald M Dawes1, Jeffrey D Ho, Johanna C Moore, Andrew P Laudenbach, Robert F Reardon, James R Miner.   

Abstract

Arrest-related deaths proximate to the use of a conducted electrical weapon (CEW) continue to generate controversy despite a better understanding of the multi-factorial nature of many of these deaths. With the rapid adoption of this technology by law enforcement, and the proliferation of companies entering the marketplace, it is important to have a method to assess the relative safety of these weapons. We had previously developed a model to assess the relative cardiac safety of CEWs. In this study, we use this model to compare the TASER X2 and the Karbon Arms MPID. Our results suggest that the TASER X2 may have an improved cardiac safety margin over the Karbon Arms MPID as determined by a smaller area of cardiac pacing on the anterior chest in our model. This model seems to offer a reproducible means of comparing the cardiac effects of CEWs.

Entities:  

Mesh:

Year:  2014        PMID: 24895072     DOI: 10.1007/s12024-014-9577-0

Source DB:  PubMed          Journal:  Forensic Sci Med Pathol        ISSN: 1547-769X            Impact factor:   2.007


  19 in total

1.  Human cardiovascular effects of a new generation conducted electrical weapon.

Authors:  Jeffrey D Ho; Donald M Dawes; Robert F Reardon; Seth R Strote; Sebastian N Kunz; Rebecca S Nelson; Erik J Lundin; Benjamin S Orozco; James R Miner
Journal:  Forensic Sci Int       Date:  2011-01-30       Impact factor: 2.395

2.  Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread.

Authors:  Jeffrey Ho; Donald Dawes; James Miner; Sebastian Kunz; Rebecca Nelson; James Sweeney
Journal:  Forensic Sci Med Pathol       Date:  2012-05-18       Impact factor: 2.007

3.  TASER electronic control devices and cardiac arrests: coincidental or causal?

Authors:  Mark W Kroll; Dhanunjaya R Lakkireddy; James R Stone; Richard M Luceri
Journal:  Circulation       Date:  2014-01-07       Impact factor: 29.690

4.  Cardiac electrophysiological consequences of neuromuscular incapacitating device discharges.

Authors:  Kumaraswamy Nanthakumar; Ian M Billingsley; Stephane Masse; Paul Dorian; Douglas Cameron; Vijay S Chauhan; Eugene Downar; Elias Sevaptsidis
Journal:  J Am Coll Cardiol       Date:  2006-07-24       Impact factor: 24.094

5.  Cardiac safety of conducted electrical devices in pigs and their effect on pacemaker function.

Authors:  Azamuddin Khaja; Gurushankar Govindarajan; Wayne McDaniel; Greg Flaker
Journal:  Am J Emerg Med       Date:  2010-10-12       Impact factor: 2.469

6.  Taser X26 discharges in swine: ventricular rhythm capture is dependent on discharge vector.

Authors:  Daniel J Valentino; Robert J Walter; Andrew J Dennis; Bosko Margeta; Frederic Starr; Kimberly K Nagy; Faran Bokhari; Dorion E Wiley; Kimberly T Joseph; Roxanne R Roberts
Journal:  J Trauma       Date:  2008-12

7.  QT PRODACT: usability of miniature pigs in safety pharmacology studies: assessment for drug-induced QT interval prolongation.

Authors:  Mayumi Kano; Tohru Toyoshi; Sakae Iwasaki; Masami Kato; Masayoshi Shimizu; Takao Ota
Journal:  J Pharmacol Sci       Date:  2005       Impact factor: 3.337

8.  Pulse variations of a conducted energy weapon (similar to the TASER X26 device): effects on muscle contraction and threshold for ventricular fibrillation*.

Authors:  Charles W Beason; James R Jauchem; C D Clark; James E Parker; David A Fines
Journal:  J Forensic Sci       Date:  2009-09       Impact factor: 1.832

9.  Cardiac effects of electrical stun guns: does position of barbs contact make a difference?

Authors:  Dhanunjaya Lakkireddy; Donald Wallick; Atul Verma; Kay Ryschon; William Kowalewski; Oussama Wazni; Jagdish Butany; David Martin; Patrick J Tchou
Journal:  Pacing Clin Electrophysiol       Date:  2008-04       Impact factor: 1.976

10.  Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects.

Authors:  William P Bozeman; William E Hauda; Joseph J Heck; Derrel D Graham; Brian P Martin; James E Winslow
Journal:  Ann Emerg Med       Date:  2009-01-21       Impact factor: 5.721

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.