Literature DB >> 24894843

Comparison of three plasma sources for ambient desorption/ionization mass spectrometry.

Kirsty McKay1, Tara L Salter, Andrew Bowfield, James L Walsh, Ian S Gilmore, James W Bradley.   

Abstract

Plasma-based desorption/ionization sources are an important ionization technique for ambient surface analysis mass spectrometry. In this paper, we compare and contrast three competing plasma based desorption/ionization sources: a radio-frequency (rf) plasma needle, a dielectric barrier plasma jet, and a low-temperature plasma probe. The ambient composition of the three sources and their effectiveness at analyzing a range of pharmaceuticals and polymers were assessed. Results show that the background mass spectrum of each source was dominated by air species, with the rf needle producing a richer ion spectrum consisting mainly of ionized water clusters. It was also seen that each source produced different ion fragments of the analytes under investigation: this is thought to be due to different substrate heating, different ion transport mechanisms, and different electric field orientations. The rf needle was found to fragment the analytes least and as a result it was able to detect larger polymer ions than the other sources.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24894843     DOI: 10.1007/s13361-014-0924-x

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  14 in total

1.  Surface analysis using a new plasma assisted desorption/ionisation source for mass spectrometry in ambient air.

Authors:  A Bowfield; D A Barrett; M R Alexander; C A Ortori; F M Rutten; T L Salter; I S Gilmore; J W Bradley
Journal:  Rev Sci Instrum       Date:  2012-06       Impact factor: 1.523

2.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

3.  Surface analysis under ambient conditions using plasma-assisted desorption/ionization mass spectrometry.

Authors:  Lucy V Ratcliffe; Frank J M Rutten; David A Barrett; Terry Whitmore; David Seymour; Claire Greenwood; Yolanda Aranda-Gonzalvo; Steven Robinson; Martin McCoustra
Journal:  Anal Chem       Date:  2007-07-12       Impact factor: 6.986

4.  Development of a dielectric barrier discharge ion source for ambient mass spectrometry.

Authors:  Na Na; Mengxia Zhao; Sichun Zhang; Chengdui Yang; Xinrong Zhang
Journal:  J Am Soc Mass Spectrom       Date:  2007-08-02       Impact factor: 3.109

5.  Dielectric barrier discharge ionization for liquid chromatography/mass spectrometry.

Authors:  Heiko Hayen; Antje Michels; Joachim Franzke
Journal:  Anal Chem       Date:  2009-12-15       Impact factor: 6.986

6.  Ambient surface mass spectrometry using plasma-assisted desorption ionization: effects and optimization of analytical parameters for signal intensities of molecules and polymers.

Authors:  T L Salter; I S Gilmore; A Bowfield; O T Olabanji; J W Bradley
Journal:  Anal Chem       Date:  2013-01-18       Impact factor: 6.986

7.  Microplasma discharge ionization source for ambient mass spectrometry.

Authors:  Joshua M Symonds; Asiri S Galhena; Facundo M Fernández; Thomas M Orlando
Journal:  Anal Chem       Date:  2010-01-15       Impact factor: 6.986

8.  Petroleum crude oil analysis using low-temperature plasma mass spectrometry.

Authors:  Mario Benassi; Arton Berisha; Wanderson Romão; Elbay Babayev; Andreas Römpp; Bernhard Spengler
Journal:  Rapid Commun Mass Spectrom       Date:  2013-04-15       Impact factor: 2.419

9.  Low-temperature plasma probe for ambient desorption ionization.

Authors:  Jason D Harper; Nicholas A Charipar; Christopher C Mulligan; Xinrong Zhang; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2008-12-01       Impact factor: 6.986

10.  A mass spectrometry study of alkanes in air plasma at atmospheric pressure.

Authors:  Ester Marotta; Cristina Paradisi
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-13       Impact factor: 3.109

View more
  3 in total

1.  Multimodal Vacuum-Assisted Plasma Ion (VaPI) Source with Transmission Mode and Laser Ablation Sampling Capabilities.

Authors:  Joel D Keelor; Paul B Farnsworth; Arthur L Weber; Heather Abbott-Lyon; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-16       Impact factor: 3.109

2.  Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry.

Authors:  Yeni P Yung; Raveendra Wickramasinghe; Anu Vaikkinen; Tiina J Kauppila; Igor V Veryovkin; Luke Hanley
Journal:  Anal Chem       Date:  2017-07-05       Impact factor: 6.986

3.  Atmospheric Plasma Supported by TiO2 Catalyst for Decolourisation of Reactive Orange 16 Dye in Water.

Authors:  Tatjana Mitrović; Nataša Tomić; Aleksandra Djukić-Vuković; Zorana Dohčević-Mitrović; Saša Lazović
Journal:  Waste Biomass Valorization       Date:  2020-01-08       Impact factor: 3.703

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.