Literature DB >> 24889906

Aortic valve type and calcification as assessed by transthoracic and transoesophageal echocardiography.

Mohamed Yousry1,2,3, Anette Rickenlund1,2, Johan Petrini2, Jonas Jenner1,2, Jan Liska2,4, Per Eriksson5, Anders Franco-Cereceda2,4, Maria J Eriksson1,2, Kenneth Caidahl1,2.   

Abstract

INTRODUCTION: Aortic valve calcification (AVC) may predict poor outcome. Bicuspid aortic valve (BAV) leads to several haemodynamic changes accelerating the progress of aortic valve (AV) disease. AIMS: To compare the diagnostic accuracy of transoesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in the assessment of aortic valve phenotype and degree of AVC, with intra-operative evaluation as a reference.
METHODS: We examined 169 patients (median age 65 years, 51 women) without significant coronary artery disease undergoing AV and/or aortic root surgery. TTE was performed within a week prior to surgery and TEE at the time of surgery.
RESULTS: Compared with surgical AVC assessment, visual evaluation using a 5-grade scoring system and real-time images showed a higher correlation (TTE r = 0·83 and TEE r = 0·82) than visual (TTE r = 0·64 and TEE 0·63) or grey scale mean (GSMn) (TTE r = 0·63 and TEE r = 0·52) assessment of end-diastolic still frames. AVC assessment using real-time images showed high intraclass correlation coefficients (TTE 0·94 and TEE 0·93). With regard to BAV, TEE was superior to TTE with a higher interobserver agreement, sensitivity and specificity (0·86, 92% and 94% versus 0·57, 77% and 82%, respectively).
CONCLUSION: Semi-quantitative AVC assessment of real-time cine loops from both TEE and TTE correlated well with intra-operative evaluation of AVC. Applying a predefined scoring system for AVC evaluation assures a high interobserver correlation. TEE was superior to TTE for evaluation of valve phenotype and should be considered when a diagnosis of BAV is clinically important.
© 2014 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Entities:  

Keywords:  bicuspid; grey scale; scoring; tricuspid; ultrasound

Mesh:

Year:  2014        PMID: 24889906     DOI: 10.1111/cpf.12166

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  7 in total

Review 1.  Low-flow/low-gradient aortic stenosis-Still a diagnostic and therapeutic challenge.

Authors:  Anja Vogelgesang; Gerd Hasenfuss; Claudius Jacobshagen
Journal:  Clin Cardiol       Date:  2017-05-23       Impact factor: 2.882

2.  MicroRNA-22 promoted osteogenic differentiation of valvular interstitial cells by inhibiting CAB39 expression during aortic valve calcification.

Authors:  Fan Yang; Suxuan Liu; Ying Gu; Yan Yan; Xueyan Ding; Liangjian Zou; Zhiyun Xu; Guokun Wang
Journal:  Cell Mol Life Sci       Date:  2022-02-21       Impact factor: 9.261

3.  Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis.

Authors:  Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch
Journal:  Cardiovasc Diagn Ther       Date:  2017-08

Review 4.  Models and Techniques to Study Aortic Valve Calcification in Vitro, ex Vivo and in Vivo. An Overview.

Authors:  Maria Bogdanova; Arsenii Zabirnyk; Anna Malashicheva; Daria Semenova; John-Peder Escobar Kvitting; Mari-Liis Kaljusto; Maria Del Mar Perez; Anna Kostareva; Kåre-Olav Stensløkken; Gareth J Sullivan; Arkady Rutkovskiy; Jarle Vaage
Journal:  Front Pharmacol       Date:  2022-06-02       Impact factor: 5.988

5.  Clinical impact of pathology-proven etiology of severely stenotic aortic valves on mid-term outcomes in patients undergoing surgical aortic valve replacement.

Authors:  Shiro Miura; Katsumi Inoue; Hiraku Kumamaru; Takehiro Yamashita; Michiya Hanyu; Shinichi Shirai; Kenji Ando
Journal:  PLoS One       Date:  2020-03-10       Impact factor: 3.240

Review 6.  Unraveling Bicuspid Aortic Valve Enigmas by Multimodality Imaging: Clinical Implications.

Authors:  Arturo Evangelista Masip; Laura Galian-Gay; Andrea Guala; Angela Lopez-Sainz; Gisela Teixido-Turà; Aroa Ruiz Muñoz; Filipa Valente; Laura Gutierrez; Ruben Fernandez-Galera; Guillem Casas; Alejandro Panaro; Alba Marigliano; Marina Huguet; Teresa González-Alujas; Jose Rodriguez-Palomares
Journal:  J Clin Med       Date:  2022-01-17       Impact factor: 4.241

7.  Aortic Valve Calcification Score in Patients with Arterial Hypertension Environmentally Exposed to Tobacco Smoke.

Authors:  Paweł Gać; Adrian Martuszewski; Patrycja Paluszkiewicz; Małgorzata Poręba; Grzegorz Mazur; Rafał Poręba
Journal:  Cardiovasc Toxicol       Date:  2021-07-26       Impact factor: 3.231

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.