Literature DB >> 24888185

Spatially selective release of aptamer-captured cells by temperature mediation.

Jing Zhu, Junyi Shang, Yuan Jia, Renjun Pei, Milan Stojanovic, Qiao Lin.   

Abstract

Isolation of cells from heterogeneous biological samples is critical in both basic biological research and clinical diagnostics. Affinity-based methods, such as those that recognise cells by binding antibodies to cell membrane biomarkers, can be used to achieve specific cell isolation. Microfluidic techniques have been employed to achieve more efficient and effective cell isolation. By employing aptamers as surface-immobilised ligands, cells can be easily released and collected after specific capture. However, these methods still have limitations in cell release efficiency and spatial selectivity. This study presents an aptamer-based microfluidic device that not only achieves specific affinity cell capture, but also enables spatially selective temperature-mediated release and retrieval of cells without detectable damage. The specific cell capture is realised by using surface-patterned aptamers in a microchamber on a temperature-control chip. Spatially selective cell release is achieved by utilising a group of microheater and temperature sensor that restricts temperature changes, and therefore the disruption of cell-aptamer interactions, to a design-specified region. Experimental results with CCRF-CEM cells and sgc8c aptamers have demonstrated the specific cell capture and temperature-mediated release of selected groups of cells with negligible disruption to their viability.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24888185      PMCID: PMC6268195          DOI: 10.1049/iet-nbt.2013.0028

Source DB:  PubMed          Journal:  IET Nanobiotechnol        ISSN: 1751-8741            Impact factor:   1.847


  29 in total

1.  Difference in infrared spectra from cultured cells dependent on cell-harvesting method.

Authors:  N Fujioka; Y Morimoto; K Takeuchi; M Yoshioka; M Kikuchi
Journal:  Appl Spectrosc       Date:  2003-02       Impact factor: 2.388

Review 2.  Microfluidics for cell separation.

Authors:  Ali Asgar S Bhagat; Hansen Bow; Han Wei Hou; Swee Jin Tan; Jongyoon Han; Chwee Teck Lim
Journal:  Med Biol Eng Comput       Date:  2010-04-23       Impact factor: 2.602

3.  Methods in cell separation for biomedical application: cryogels as a new tool.

Authors:  Ashok Kumar; Aditi Bhardwaj
Journal:  Biomed Mater       Date:  2008-08-15       Impact factor: 3.715

Review 4.  Cell death and proliferation in acute slices and organotypic cultures of mammalian CNS.

Authors:  Laura Lossi; Silvia Alasia; Chiara Salio; Adalberto Merighi
Journal:  Prog Neurobiol       Date:  2009-01-24       Impact factor: 11.685

5.  Aptamer-mediated efficient capture and release of T lymphocytes on nanostructured surfaces.

Authors:  Li Chen; Xueli Liu; Bin Su; Jing Li; Lei Jiang; Dong Han; Shutao Wang
Journal:  Adv Mater       Date:  2011-08-22       Impact factor: 30.849

6.  Demonstration and Characterization of Biomolecular Enrichment on Microfluidic Aptamer-Functionalized Surfaces.

Authors:  Thai Huu Nguyen; Renjun Pei; Milan Stojanovic; Qiao Lin
Journal:  Sens Actuators B Chem       Date:  2011-07-05       Impact factor: 7.460

7.  Recognition and capture of breast cancer cells using an antibody-based platform in a microelectromechanical systems device.

Authors:  Z Du; K H Cheng; M W Vaughn; N L Collie; L S Gollahon
Journal:  Biomed Microdevices       Date:  2007-02       Impact factor: 2.838

8.  Isolation of rare circulating tumour cells in cancer patients by microchip technology.

Authors:  Sunitha Nagrath; Lecia V Sequist; Shyamala Maheswaran; Daphne W Bell; Daniel Irimia; Lindsey Ulkus; Matthew R Smith; Eunice L Kwak; Subba Digumarthy; Alona Muzikansky; Paula Ryan; Ulysses J Balis; Ronald G Tompkins; Daniel A Haber; Mehmet Toner
Journal:  Nature       Date:  2007-12-20       Impact factor: 49.962

9.  Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor.

Authors:  André A Adams; Paul I Okagbare; Juan Feng; Matuesz L Hupert; Don Patterson; Jost Göttert; Robin L McCarley; Dimitris Nikitopoulos; Michael C Murphy; Steven A Soper
Journal:  J Am Chem Soc       Date:  2008-06-17       Impact factor: 15.419

Review 10.  Characterization of aptamer-protein complexes by X-ray crystallography and alternative approaches.

Authors:  Vincent J B Ruigrok; Mark Levisson; Johan Hekelaar; Hauke Smidt; Bauke W Dijkstra; John Van der Oost
Journal:  Int J Mol Sci       Date:  2012-08-22       Impact factor: 6.208

View more
  3 in total

Review 1.  Trends in the Design and Development of Specific Aptamers Against Peptides and Proteins.

Authors:  Maryam Tabarzad; Marzieh Jafari
Journal:  Protein J       Date:  2016-04       Impact factor: 2.371

2.  Calcium Influx of Mast Cells Is Inhibited by Aptamers Targeting the First Extracellular Domain of Orai1.

Authors:  Renshan Sun; Yongqiang Yang; Xinze Ran; Tao Yang
Journal:  PLoS One       Date:  2016-07-08       Impact factor: 3.240

3.  Biophysical induction of cell release for minimally manipulative cell enrichment strategies.

Authors:  Pascal Joly; Thomas Schaus; Andrea Sass; Anke Dienelt; Alexander S Cheung; Georg N Duda; David J Mooney
Journal:  PLoS One       Date:  2017-06-30       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.