Effects of ethyl chloride spray on pain and parameters of needle electromyography in the upper extremity.

Young-Eun Moon1, Sang-Hyun Kim.   

Abstract

OBJECTIVE: The aim of this study was to compare the effects of ethyl chloride and placebo sprays for reducing pain induced by needle electromyography and changes in parameters of the motor unit action potential during needle electromyography of the upper extremity.
DESIGN: Sixty patients were randomized into the ethyl chloride or placebo spray groups. In both groups, spray was applied just before needle electromyography of the flexor carpi radialis, and a visual analog scale to evaluate the pain of needle electromyography and a five-point Likert scale for patient satisfaction and preference for reexamination were compared between the two groups. Then, changes in the amplitude, phases, turns, and duration of the motor unit action potential during needle electromyography of the biceps brachii were compared before and after spraying in each group.
RESULTS: The visual analog scale was significantly lower, and patient satisfaction and preference for reexamination were significantly higher in the ethyl chloride spray group. Among the parameters of the motor unit action potential, there were no significant changes except for an increased duration after spraying with ethyl chloride.
CONCLUSIONS: Ethyl chloride spray can effectively reduce pain, but it must be used with caution because it may affect parameters of the motor unit action potential during needle electromyography.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24879550     DOI: 10.1097/PHM.0000000000000106

Source DB:  PubMed          Journal:  Am J Phys Med Rehabil        ISSN: 0894-9115            Impact factor:   2.159


  3 in total

1.  Periodical assessment of electrophysiological recovery following sciatic nerve crush via surface stimulation in rats.

Authors:  Yaxian Wang; Hongkui Wang; Daguo Mi; Xiaosong Gu; Wen Hu
Journal:  Neurol Sci       Date:  2014-11-14       Impact factor: 3.307

2.  Preventive effect of a vapocoolant spray on propofol-induced pain: a prospective, double-blind, randomized study.

Authors:  Young Eun Moon; Michael Y Lee; Dong Hyun Kim
Journal:  J Anesth       Date:  2017-08-05       Impact factor: 2.078

3.  Sterility of Ethyl Chloride Spray After Use in the Clinic.

Authors:  Kristin Sandrowski; Jack Graham; Samantha Knott; Noreen Hickok; Keith Fitzgerald; Pedro K Beredjiklian; Michael Rivlin
Journal:  Hand (N Y)       Date:  2019-05-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.