Literature DB >> 24875529

Gold-mercaptopropionic acid-polyethylenimine composite based DNA sensor for early detection of rheumatic heart disease.

Swati Singh1, Ankur Kaushal, Shashi Khare, Pradeep Kumar, Ashok Kumar.   

Abstract

The first gold-mercaptopropionic acid-polyethylenimine composite based electrochemical DNA biosensor was fabricated for the early detection of Streptococcus pyogenes infection in humans causing rheumatic heart disease (heart valve damage). No biosensor is available for the detection of rheumatic heart disease (RHD). Therefore, the mga gene based sensor was developed by the covalent immobilization of a 5'-carboxyl modified single stranded DNA probe onto the gold composite electrode. The immobilized probe was hybridized with the genomic DNA (G-DNA) of S. pyogenes from throat swabs and the electrochemical response was measured by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance (EI). Covalent immobilization of the probe onto the gold composite and its hybridization with G-DNA was characterized by FTIR and SEM. The sensitivity of the sensor was 110.25 μA cm(-2) ng(-1) with DPV and the lower limit of detection was 10 pg per 6 μL. The sensor was validated with patient throat swab samples and results were compared with available methods. The sensor is highly specific to S. pyogenes and can prevent damage to heart valves by the early detection of the infection in only 30 min.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24875529     DOI: 10.1039/c4an00324a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  Gene Specific Impedimetric Bacterial DNA Sensor for Rheumatic Heart Disease.

Authors:  Swati Singh; Ankur Kaushal; Sunil Gupta; Ashok Kumar
Journal:  Indian J Microbiol       Date:  2016-09-22       Impact factor: 2.461

2.  Nano-Au/cMWCNT Modified speB Gene Specific Amperometric Sensor for Rapidly Detecting Streptococcus pyogenes causing Rheumatic Heart Disease.

Authors:  Ankur Kaushal; Swati Singh; Ashok Kumar; Dinesh Kumar
Journal:  Indian J Microbiol       Date:  2017-01-03       Impact factor: 2.461

3.  Detection methods for influenza A H1N1 virus with special reference to biosensors: a review.

Authors:  Ravina R; Anita Dalal; Hari Mohan; Minakshi Prasad; C S Pundir
Journal:  Biosci Rep       Date:  2020-02-28       Impact factor: 3.840

Review 4.  Recent Advances in the Rheumatic Fever and Rheumatic Heart Disease Continuum.

Authors:  Joselyn Rwebembera; Bruno Ramos Nascimento; Neema W Minja; Sarah de Loizaga; Twalib Aliku; Luiza Pereira Afonso Dos Santos; Bruno Fernandes Galdino; Luiza Silame Corte; Vicente Rezende Silva; Andrew Young Chang; Walderez Ornelas Dutra; Maria Carmo Pereira Nunes; Andrea Zawacki Beaton
Journal:  Pathogens       Date:  2022-01-28

5.  Antibody Modified Gold Electrode as an Impedimetric Biosensor for the Detection of Streptococcus pyogenes.

Authors:  Natalia Malinowska; Wioleta Białobrzeska; Tomasz Łęga; Katarzyna Pałka; Karolina Dziąbowska; Sabina Żołędowska; Elżbieta Czaczyk; Katarzyna Pala; Dawid Nidzworski
Journal:  Sensors (Basel)       Date:  2020-09-17       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.