Literature DB >> 24869758

Potential infection risk from thyroid radiation protection.

Siegfried Feierabend1, Geoff Siegel.   

Abstract

OBJECTIVES: Thyroid shields that are worn for personal radiation protection in the operating room are often exposed above the sterile gown and are likely a bacterial source of wound infections. We would like to determine what bacteria may be present on the portion of the thyroid shield, which is facing the operative table.
METHODS: Community thyroid shields were collected from around the operative rooms. The shields were then cultured on the side, which faces the patient and operative table. The shields where then cleaned with a readily available cleaner and again cultured to evaluate the reduction of bacterial load. Samples were cultured on nonselective media for 72 hours.
RESULTS: Thirty-two total thyroid shields were cultured before and after cleaning. Before cleaning, 81% of thyroid shields grew out at least 1 type of bacteria with 90% being coagulase negative staphylococcus. Postcleaning culturable contamination was reduced by 70% (P < 0.05).
CONCLUSIONS: The thyroid shield that is often visible above the neckline is contaminated with strains of bacteria that are commonly implicated in postoperative infections. Cleaning the thyroid shield with readily available cleaners can significantly reduce the bacterial burden as detectable by culture. Based on the primary research question, this article is a basic science article.

Entities:  

Mesh:

Year:  2015        PMID: 24869758     DOI: 10.1097/BOT.0000000000000161

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  5 in total

1.  Evaluation of bacterial presence on lead X-ray aprons utilised in the operating room via IBIS and standard culture methods.

Authors:  Sameer Jain; Rebecca A Rajfer; Rachel Melton-Kreft; Laura Nistico; Mark C Miller; Paul Stoodley; Daniel T Altman; Gregory T Altman
Journal:  J Infect Prev       Date:  2019-04-15

2.  Bacterial contamination of protective lead garments in an operating room setting.

Authors:  Ron Gilat; Ilan Mitchnik; Eran Beit Ner; Noam Shohat; Eran Tamir; Yoram A Weil; Tsilia Lazarovitch; Gabriel Agar
Journal:  J Infect Prev       Date:  2020-08-29

Review 3.  Intraoperative radiation safety in orthopaedics: a review of the ALARA (As low as reasonably achievable) principle.

Authors:  Daniel J Kaplan; Jay N Patel; Frank A Liporace; Richard S Yoon
Journal:  Patient Saf Surg       Date:  2016-12-12

4.  Thyroid radiation shields: A potential source of intraoperative infection.

Authors:  T McAleese; J M Broderick; E Stanley; R Curran
Journal:  J Orthop       Date:  2020-06-19

5.  Microbial Contamination Risk and Disinfection of Radiation Protective Garments.

Authors:  Stephen Balter; Michelle A Rodriguez; Janett A Pike; Norman J Kleiman
Journal:  Health Phys       Date:  2021-02-01       Impact factor: 2.922