Literature DB >> 24865391

Ablation of carious dental tissue using an ultrashort pulsed laser (USPL) system.

Christoph Engelbach1, Claudia Dehn, Christoph Bourauel, Jörg Meister, Matthias Frentzen.   

Abstract

The aim of the study was to investigate the efficiency of caries removal employing an ultrashort pulsed laser (USPL) and to compare the results regarding to the ablation rate of sound enamel and dentin including surface texture. The study was performed with 59 freshly extracted carious human teeth. Two cavities with an edge length of 1 × 1 mm per tooth were created: one in the dental decay and one in sound hard tissue. For this purpose a 9-W Nd:YVO4 laser with a center wavelength of 1,064 nm and a pulse duration of 8 ps at a repetition rate of 500 kHz was used. A scanner system moved the laser beam across the surface with a scan speed of 2,000 mm/s. Ablated volume and roughness R z of the cavity ground were measured using an optical profilometer. Subsequently, the specimens were cut to undecalcified sections for histological investigations. The removal of dental decay (dentin, 14.9 mm(3)/min; enamel, 12.8 mm(3)/min) was significantly higher (p < 0.05) compared to the removal of sound tissues (dentin, 4.2 mm(3)/min; enamel, 3.8 mm(3)/min). The arithmetic means of the surface roughness R z were 8.5 μm in carious enamel, 15.43 μm in carious dentin, 4.83 μm in sound enamel and 5.52 μm in sound dentin. Light microscopic investigations did not indicate any side effects in the surrounding tissues. Regarding the ablation rate of dental decay using the USPL system, caries removal seems to be much more efficient for cavity preparation.

Entities:  

Mesh:

Year:  2014        PMID: 24865391     DOI: 10.1007/s10103-014-1594-4

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  39 in total

1.  Bonding to Er-YAG-laser-treated dentin.

Authors:  L Ceballo; M Toledano; R Osorio; F R Tay; G W Marshall
Journal:  J Dent Res       Date:  2002-02       Impact factor: 6.116

2.  The effect of Nd:YAG radiation at nanosecond pulse duration on dentine crater depth.

Authors:  A McDonald; N Claffey; G Pearson; W Blau; D Setchell
Journal:  Biomaterials       Date:  2002-01       Impact factor: 12.479

3.  Nature of light scattering in dental enamel and dentin at visible and near-infrared wavelengths.

Authors:  D Fried; R E Glena; J D Featherstone; W Seka
Journal:  Appl Opt       Date:  1995-03-01       Impact factor: 1.980

4.  Ultrashort pulsed laser (USPL) application in dentistry: basic investigations of ablation rates and thresholds on oral hard tissue and restorative materials.

Authors:  Florian Schelle; Sebastian Polz; Hatim Haloui; Andreas Braun; Claudia Dehn; Matthias Frentzen; Jörg Meister
Journal:  Lasers Med Sci       Date:  2013-04-23       Impact factor: 3.161

5.  Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate.

Authors:  R Hibst; U Keller
Journal:  Lasers Surg Med       Date:  1989       Impact factor: 4.025

6.  Evaluation of selective caries removal by a fluorescence feedback-controlled Er:YAG laser in vitro.

Authors:  J Eberhard; A K Eisenbeiss; A Braun; J Hedderich; S Jepsen
Journal:  Caries Res       Date:  2005 Nov-Dec       Impact factor: 4.056

7.  Cavity preparation with the Nd:YLF picosecond laser.

Authors:  M H Niemz
Journal:  J Dent Res       Date:  1995-05       Impact factor: 6.116

8.  Caries-removal effectiveness and minimal-invasiveness potential of caries-excavation techniques: a micro-CT investigation.

Authors:  Aline de A Neves; Eduardo Coutinho; Jan De Munck; Bart Van Meerbeek
Journal:  J Dent       Date:  2010-11-25       Impact factor: 4.379

9.  The in vitro morphological effects of some current pre-treatments on dentin surface: a SEM evaluation.

Authors:  Marcos Antonio Japiassú Resende Montes; Mario Fernando de Goes; Maŕio Alexandre Coelho Sinhoreti
Journal:  Oper Dent       Date:  2005 Mar-Apr       Impact factor: 2.440

10.  Selective targeting of protein, water, and mineral in dentin using UV and IR pulse lasers: the effect on the bond strength to composite restorative materials.

Authors:  Karishma K Sheth; Michal Staninec; Anupama V Sarma; Daniel Fried
Journal:  Lasers Surg Med       Date:  2004       Impact factor: 4.025

View more
  1 in total

1.  Regulation and Measurement of the Heat Generated by Automatic Tooth Preparation in a Confined Space.

Authors:  Fusong Yuan; Jianqiao Zheng; Yuchun Sun; Yong Wang; Peijun Lyu
Journal:  Photomed Laser Surg       Date:  2017-06       Impact factor: 2.796

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.