Literature DB >> 24862216

An investigation into the effects of temporal resolution on hepatic dynamic contrast-enhanced MRI in volunteers and in patients with hepatocellular carcinoma.

Andrew B Gill1, Richard T Black, David J Bowden, Andrew N Priest, Martin J Graves, David J Lomas.   

Abstract

This study investigated the effect of temporal resolution on the dual-input pharmacokinetic (PK) modelling of dynamic contrast-enhanced MRI (DCE-MRI) data from normal volunteer livers and from patients with hepatocellular carcinoma. Eleven volunteers and five patients were examined at 3 T. Two sections, one optimized for the vascular input functions (VIF) and one for the tissue, were imaged within a single heart-beat (HB) using a saturation-recovery fast gradient echo sequence. The data was analysed using a dual-input single-compartment PK model. The VIFs and/or uptake curves were then temporally sub-sampled (at interval ▵t = [2-20] s) before being subject to the same PK analysis. Statistical comparisons of tumour and normal tissue PK parameter values using a 5% significance level gave rise to the same study results when temporally sub-sampling the VIFs to HB < ▵t <4 s. However, sub-sampling to ▵t > 4 s did adversely affect the statistical comparisons. Temporal sub-sampling of just the liver/tumour tissue uptake curves at ▵t ≤ 20 s, whilst using high temporal resolution VIFs, did not substantially affect PK parameter statistical comparisons. In conclusion, there is no practical advantage to be gained from acquiring very high temporal resolution hepatic DCE-MRI data. Instead the high temporal resolution could be usefully traded for increased spatial resolution or SNR.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24862216     DOI: 10.1088/0031-9155/59/12/3187

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Intravoxel incoherent motion diffusion-weighted imaging of hepatocellular carcinoma: Is there a correlation with flow and perfusion metrics obtained with dynamic contrast-enhanced MRI?

Authors:  Stefanie J Hectors; Mathilde Wagner; Cecilia Besa; Octavia Bane; Hadrien A Dyvorne; M Isabel Fiel; Hongfa Zhu; Michael Donovan; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2016-02-26       Impact factor: 4.813

2.  Robust and efficient pharmacokinetic parameter non-linear least squares estimation for dynamic contrast enhanced MRI of the prostate.

Authors:  Soudabeh Kargar; Eric A Borisch; Adam T Froemming; Akira Kawashima; Lance A Mynderse; Eric G Stinson; Joshua D Trzasko; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2017-12-24       Impact factor: 2.546

3.  Estimating liver perfusion from free-breathing continuously acquired dynamic gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced acquisition with compressed sensing reconstruction.

Authors:  Hersh Chandarana; Tobias Kai Block; Justin Ream; Artem Mikheev; Samuel H Sigal; Ricardo Otazo; Henry Rusinek
Journal:  Invest Radiol       Date:  2015-02       Impact factor: 6.016

4.  Optimal acquisition and modeling parameters for accurate assessment of low Ktrans blood-brain barrier permeability using dynamic contrast-enhanced MRI.

Authors:  Samuel R Barnes; Thomas S C Ng; Axel Montagne; Meng Law; Berislav V Zlokovic; Russell E Jacobs
Journal:  Magn Reson Med       Date:  2015-06-16       Impact factor: 4.668

5.  DCE-MRI of hepatocellular carcinoma: perfusion quantification with Tofts model versus shutter-speed model--initial experience.

Authors:  Guido H Jajamovich; Wei Huang; Cecilia Besa; Xin Li; Aneela Afzal; Hadrien A Dyvorne; Bachir Taouli
Journal:  MAGMA       Date:  2015-12-08       Impact factor: 2.310

6.  DCE-MRI of the liver: reconstruction of the arterial input function using a low dose pre-bolus contrast injection.

Authors:  Guido H Jajamovich; Claudia Calcagno; Hadrien A Dyvorne; Henry Rusinek; Bachir Taouli
Journal:  PLoS One       Date:  2014-12-29       Impact factor: 3.240

7.  Improved hepatic arterial fraction estimation using cardiac output correction of arterial input functions for liver DCE MRI.

Authors:  Manil D Chouhan; Alan Bainbridge; David Atkinson; Shonit Punwani; Rajeshwar P Mookerjee; Mark F Lythgoe; Stuart A Taylor
Journal:  Phys Med Biol       Date:  2016-12-21       Impact factor: 3.609

8.  Simultaneous evaluation of perfusion and morphology using GRASP MRI in hepatic fibrosis.

Authors:  Jeong Hee Yoon; Jeong Min Lee; Mi Hye Yu; Bo Yun Hur; Robert Grimm; Steven Sourbron; Hersh Chandarana; Yohan Son; Susmita Basak; Kyoung-Bun Lee; Nam-Joon Yi; Kwang-Woong Lee; Kyung-Suk Suh
Journal:  Eur Radiol       Date:  2021-06-12       Impact factor: 5.315

9.  Vascular assessment of liver disease-towards a new frontier in MRI.

Authors:  Manil D Chouhan; Mark F Lythgoe; Rajeshwar P Mookerjee; Stuart A Taylor
Journal:  Br J Radiol       Date:  2016-05-16       Impact factor: 3.039

10.  Estimation of contrast agent bolus arrival delays for improved reproducibility of liver DCE MRI.

Authors:  Manil D Chouhan; Alan Bainbridge; David Atkinson; Shonit Punwani; Rajeshwar P Mookerjee; Mark F Lythgoe; Stuart A Taylor
Journal:  Phys Med Biol       Date:  2016-09-12       Impact factor: 3.609

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.