Literature DB >> 24860040

Active electrode IC for EEG and electrical impedance tomography with continuous monitoring of contact impedance.

Marco Guermandi, Roberto Cardu, Eleonora Franchi Scarselli, Roberto Guerrieri.   

Abstract

The IC presented integrates the front-end for EEG and Electrical Impedance Tomography (EIT) acquisition on the electrode, together with electrode-skin contact impedance monitoring and EIT current generation, so as to improve signal quality and integration of the two techniques for brain imaging applications. The electrode size is less than 2 cm(2) and only 4 wires connect the electrode to the back-end. The readout circuit is based on a Differential Difference Amplifier and performs single-ended amplification and frequency division multiplexing of the three signals that are sent to the back-end on a single wire which also provides power supply. Since the system's CMRR is a function of each electrode's gain accuracy, an analysis is performed on how this is influenced by mismatches in passive and active components. The circuit is fabricated in 0.35 μm CMOS process and occupies 4 mm(2), the readout circuit consumes 360 μW, the input referred noise for bipolar EEG signal acquisition is 0.56 μVRMS between 0.5 and 100 Hz and almost halves if only EEG signal is acquired.

Mesh:

Year:  2014        PMID: 24860040     DOI: 10.1109/TBCAS.2014.2311836

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  5 in total

1.  Multi-Channel Biopotential Acquisition System Using Frequency-Division Multiplexing With Cable Motion Artifact Suppression.

Authors:  Jinyong Kim; Hyunkyu Ouh; Matthew L Johnston
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2022-02-17       Impact factor: 3.833

Review 2.  Miniaturization for wearable EEG systems: recording hardware and data processing.

Authors:  Minjae Kim; Seungjae Yoo; Chul Kim
Journal:  Biomed Eng Lett       Date:  2022-06-06

3.  A Multitasking Electrical Impedance Tomography System Using Titanium Alloy Electrode.

Authors:  Abdalla Salama; Amin Malekmohammadi; Shahram Mohanna; Rajprasad Rajkumar
Journal:  Int J Biomed Imaging       Date:  2017-10-31

4.  Two-Wired Active Spring-Loaded Dry Electrodes for EEG Measurements.

Authors:  Seungchan Lee; Younghak Shin; Anil Kumar; Kiseon Kim; Heung-No Lee
Journal:  Sensors (Basel)       Date:  2019-10-21       Impact factor: 3.576

5.  Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography.

Authors:  James Avery; Brett Packham; Hwan Koo; Ben Hanson; David Holder
Journal:  Sensors (Basel)       Date:  2020-12-09       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.