Abstract

A multi-channel, CMOS-based biopotential acquisition system is presented that uses amplitude modulated, frequency division multiplexing (AM-FDM) to decrease wire count and provide resilience against motion artifacts and cable noise. Differential active electrode (AE) pairs capture surface biopotential signals, each modulated by a different carrier frequency and combined via current-domain summing. The presented approach requires only a single wire for signal transmission between AEs and back-end readout, along with clock and ground wires, to support multiple active electrodes using a 3-wire cable. Frequency modulation prior to transmission mitigates the effect of low-frequency cable motion artifacts and 50/60 Hz mains interference in the cable. A prototype FDM-based biopotential acquisition system was implemented in a 180 nm CMOS process, including a four-channel front-end active electrode IC for signal conditioning and modulation, and a back-end IC for demodulation and digitization. Each channel occupies 0.75 mm [Formula: see text] and consumes 43.8 μ W, inclusive of ADC power. Using both AE and BE ICs, a four-channel biopotential recording system is demonstrated using a 3-wire interface, where the system achieves attenuation of low-frequency cable motion artifacts by 15X and 60 Hz mains noise coupled into the cable by 62X.

Entities:  

Mesh:

Year:  2022        PMID: 34847042      PMCID: PMC8942403          DOI: 10.1109/TBCAS.2021.3131642

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  18 in total

1.  The impact of the MIT-BIH arrhythmia database.

Authors:  G B Moody; R G Mark
Journal:  IEEE Eng Med Biol Mag       Date:  2001 May-Jun

2.  Computer analysis of multichannel ECG.

Authors:  Roman Trobec
Journal:  Comput Biol Med       Date:  2003-05       Impact factor: 4.589

Review 3.  Dry-contact and noncontact biopotential electrodes: methodological review.

Authors:  Yu Mike Chi; Tzyy-Ping Jung; Gert Cauwenberghs
Journal:  IEEE Rev Biomed Eng       Date:  2010

4.  A 13-Channel 1.53-mW 11.28-mm2 Electrical Impedance Tomography SoC Based on Frequency Division Multiplexing for Lung Physiological Imaging.

Authors:  Boxiao Liu; Guoxing Wang; Yongfu Li; Lei Zeng; Hui Li; Yue Gao; Yixin Ma; Yong Lian; Chun-Huat Heng
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-07-15       Impact factor: 3.833

Review 5.  Active Electrodes for Wearable EEG Acquisition: Review and Electronics Design Methodology.

Authors:  Jiawei Xu; Srinjoy Mitra; Chris Van Hoof; Refet Firat Yazicioglu; Kofi A A Makinwa
Journal:  IEEE Rev Biomed Eng       Date:  2017-01-20

6.  Wireless Smartphone Control using Electromyography and Automated Gesture Recognition.

Authors:  Jacob Dawes; Makenzie Brian; Hayden Bialek; Matthew L Johnston
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

7.  A Fully Integrated Wireless Compressed Sensing Neural Signal Acquisition System for Chronic Recording and Brain Machine Interface.

Authors:  Xilin Liu; Milin Zhang; Tao Xiong; Andrew G Richardson; Timothy H Lucas; Peter S Chin; Ralph Etienne-Cummings; Trac D Tran; Jan Van der Spiegel
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2016-07-18       Impact factor: 3.833

8.  Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation.

Authors:  Francesco Negro; Silvia Muceli; Anna Margherita Castronovo; Ales Holobar; Dario Farina
Journal:  J Neural Eng       Date:  2016-02-29       Impact factor: 5.379

9.  Long-term EEG in children.

Authors:  A Montavont; A Kaminska; C Soufflet; D Taussig
Journal:  Neurophysiol Clin       Date:  2015-01-15       Impact factor: 3.734

10.  Robust Biopotential Acquisition via a Distributed Multi-Channel FM-ADC.

Authors:  Julian Warchall; Paul Theilmann; Yuxuan Ouyang; Harinath Garudadri; Patrick P Mercier
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-09-25       Impact factor: 3.833

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.