Acute delayed infection: increased risk in failed metal on metal total hip arthroplasty.

Hernan A Prieto1, Elie F Berbari1, Rafael J Sierra1.   

Abstract

Adverse local tissue reactions occurring in metal-on-metal total hip arthroplasty (MoM THA) could potentially lead to secondary failure modes such as dislocation or infection. The authors report a series of 124 patients treated with MoM hip arthroplasty between 2006 and 2010 with a minimum follow-up of 3 years. Eight hips presented with acute delayed or late periprosthetic joint infection (PJI) (defined as an infection occurring after 3 months in an otherwise well functioning implant). The rate of infection observed was higher than expected, almost 4 times higher (5.6%) compared to previous historical cohorts from our institution (1.3%). This high risk of infection in patients with DePuy ASR implants requires further study but we theorize that the increased prevalence of infection could be due to a combination of particulate debris, molecular (rather than particulate) effects of Co and Cr ions on soft tissues, and/or products of corrosion that may change the local environment predisposing to infection.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Metal-on-metal; complications; infection; revision arthroplasty; total hip arthroplasty

Mesh:

Substances:

Year:  2014        PMID: 24851788     DOI: 10.1016/j.arth.2014.04.008

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Revision for taper corrosion at the head-neck junction: pearls and pitfalls.

Authors:  Brian J McGrory; Brigham R McKenney
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

Review 2.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

3.  Cobalt and Chromium Ion Release in Metal-on-Polyethylene and Ceramic-on-Polyethylene THA: A Simulator Study With Cellular and Microbiological Correlations.

Authors:  Cody C Wyles; Christopher R Paradise; Thao L Masters; Robin Patel; Andre J van Wijnen; Matthew P Abdel; Robert T Trousdale; Rafael J Sierra
Journal:  J Arthroplasty       Date:  2019-11-27       Impact factor: 4.757

4.  Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.

Authors:  Colin T Penrose; Thorsten M Seyler; Samuel S Wellman; Michael P Bolognesi; Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

5.  A Rare Case of Metallosis Co-occurring With Chronic Prosthetic Joint Infection in Total Hip Arthroplasty.

Authors:  Allicia O Imada; Brandon M Painter; Bryce Clinger; Michael M Decker
Journal:  Cureus       Date:  2022-01-23

Review 6.  The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty.

Authors:  Giorgio Perino; Ivan De Martino; Lingxin Zhang; Zhidao Xia; Jiri Gallo; Shonali Natu; David Langton; Monika Huber; Anastasia Rakow; Janosch Schoon; Enrique Gomez-Barrena; Veit Krenn
Journal:  EFORT Open Rev       Date:  2021-06-28

7.  Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

Authors:  Florian Witt; Julian Gührs; Michael M Morlock; Nicholas E Bishop
Journal:  PLoS One       Date:  2015-08-17       Impact factor: 3.240