Trajectory correction for free-breathing radial cine MRI.

Guido Buonincontri1, Carmen Methner2, Thomas Krieg2, T Adrian Carpenter3, Stephen J Sawiak4.   

Abstract

Radial acquisitions can suffer from trajectory errors leading to reduced image quality. Here we present a new method of trajectory correction that uses all spokes of a radial acquisition and compare it to an existing method that uses a two-spoke pre-scan calibration. For both methods, estimates of the necessary shifts were made using magnitude or phase data and the performances were compared. The additional effect of B0 correction was considered in all cases. Mouse cardiac scans were used for the comparisons and we also compared the quality of navigator signals obtained from the radial data with each technique. The proposed method gave improved image quality over the existing method, as assessed by visual inspection and quantitative evaluation of artifacts. The typical shading artifacts seen in radial scans were significantly reduced with both approaches, with phase-based corrections generally outperforming magnitude-based methods. B0 correction gave further improvements in each case. Furthermore, modulation of navigator signals due to the acquisition angle was significantly reduced with the new technique. We show that our proposed method works well to reduce artifacts seen in mouse cardiac imaging that can make faster imaging feasible.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Eddy currents; Free breathing; Radial MRI; Retrospective gating

Mesh:

Year:  2014        PMID: 24848290     DOI: 10.1016/j.mri.2014.04.006

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

2.  Magnetic resonance fingerprinting with dictionary-based fat and water separation (DBFW MRF): A multi-component approach.

Authors:  Matteo Cencini; Laura Biagi; Joshua D Kaggie; Rolf F Schulte; Michela Tosetti; Guido Buonincontri
Journal:  Magn Reson Med       Date:  2018-12-21       Impact factor: 4.668

3.  Dynamic MRI of swallowing: real-time volumetric imaging at 12 frames per second at 3 T.

Authors:  Luuk Voskuilen; Jasper Schoormans; Oliver J Gurney-Champion; Alfons J M Balm; Gustav J Strijkers; Ludi E Smeele; Aart J Nederveen
Journal:  MAGMA       Date:  2021-11-15       Impact factor: 2.533

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.