Literature DB >> 24844670

Choice of reconstructed tissue properties affects interpretation of lung EIT images.

Bartłomiej Grychtol1, Andy Adler.   

Abstract

Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse problem is commonly linearized and only changes in electrical properties are reconstructed. Early algorithms reconstructed changes in resistivity, while most recent work using the finite element method reconstructs conductivity. Recently, we demonstrated that EIT images of ventilation can be misleading if the electrical contrasts within the thorax are not taken into account during the image reconstruction process. In this paper, we explore the effect of the choice of the reconstructed electrical properties (resistivity or conductivity) on the resulting EIT images. We show in simulation and experimental data that EIT images reconstructed with the same algorithm but with different parametrizations lead to large and clinically significant differences in the resulting images, which persist even after attempts to eliminate the impact of the parameter choice by recovering volume changes from the EIT images. Since there is no consensus among the most popular reconstruction algorithms and devices regarding the parametrization, this finding has implications for potential clinical use of EIT. We propose a program of research to develop reconstruction techniques that account for both the relationship between air volume and electrical properties of the lung and artefacts introduced by the linearization.

Entities:  

Mesh:

Year:  2014        PMID: 24844670     DOI: 10.1088/0967-3334/35/6/1035

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Postmortem Electrical Conductivity Changes of Dicentrarchus labrax Skeletal Muscle: Root Mean Square (RMS) Parameter in Estimating Time since Death.

Authors:  Jessica Maria Abbate; Gabriele Grifò; Fabiano Capparucci; Francesca Arfuso; Serena Savoca; Luca Cicero; Giancarlo Consolo; Giovanni Lanteri
Journal:  Animals (Basel)       Date:  2022-04-20       Impact factor: 3.231

2.  Electrical impedance tomography: Amplitudes of cardiac related impedance changes in the lung are highly position dependent.

Authors:  Michael Graf; Thomas Riedel
Journal:  PLoS One       Date:  2017-11-16       Impact factor: 3.240

3.  Effects of individualized electrical impedance tomography and image reconstruction settings upon the assessment of regional ventilation distribution: Comparison to 4-dimensional computed tomography in a porcine model.

Authors:  Florian Thürk; Stefan Boehme; Daniel Mudrak; Stefan Kampusch; Alice Wielandner; Helmut Prosch; Christina Braun; Frédéric P R Toemboel; Johannes Hofmanninger; Eugenijus Kaniusas
Journal:  PLoS One       Date:  2017-08-01       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.