Literature DB >> 24838134

Balloon-expandable prostheses for transcatheter aortic valve replacement.

Henrique Barbosa Ribeiro1, Marina Urena1, Ricardo Allende1, Ignacio J Amat-Santos1, Josep Rodés-Cabau2.   

Abstract

The implantation of a transcatheter heart valve (THV) through a balloon-expandable system played a major role in the early stages of transcatheter aortic valve replacement (TAVR). The technology consists of sewing a foldable biological cardiac valve inside a metallic stent frame, and then crimping the device into a balloon in order to implant the valve at the level of the aortic annulus through balloon inflation. The use of balloon-expandable valves underwent a rapid expansion in the years following the pioneering experience of 2002, and recent large multicenter trials and registries have confirmed the safety and efficacy of TAVR using balloon-expandable valves. The randomized Placement of Aortic Transcatheter Valves (PARTNER) trial showed both the superiority and non-inferiority of TAVR with the balloon-expandable Edwards-Sapien system compared to medical treatment (non-operable patients) and surgical aortic valve replacement (high risk patients), respectively. Balloon-expandable valves have been associated with excellent hemodynamic results (residual mean gradient <15 mm Hg in most cases), though residual paravalvular aortic regurgitation is frequent (trivial or mild in the majority of patients, moderate or severe in <10%). Valve durability studies with up to 5-year follow-up have shown maintained valve hemodynamics over time with only a minimal decrease in valve area and no increase in aortic regurgitation. Future improvements in the balloon-expandable THV technology such as implementing anti-paravalvular leak features (ex. Sapien 3 valve), and showing its efficacy for the treatment of non-high risk patients (ongoing PARTNER II trial) will probably lead to broader use in a lower risk population in the near future.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aortic stenosis; Balloon-expandable; Transcatheter aortic Valve replacement; Transcatheter heart valve

Mesh:

Year:  2014        PMID: 24838134     DOI: 10.1016/j.pcad.2014.02.001

Source DB:  PubMed          Journal:  Prog Cardiovasc Dis        ISSN: 0033-0620            Impact factor:   8.194


  6 in total

1.  Balloon- or Self-Expandable TAVI: Clinical Equipoise?

Authors:  John Jose; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Interv Cardiol       Date:  2015-05

2.  Migration and surgical retrieval of transcatheter aortic valve.

Authors:  Ajmer Singh; Vinit Garg; Yatin Mehta
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-09-20

Review 3.  Transcatheter aortic valve implantation in the elderly: who to refer?

Authors:  Matthew Finn; Philip Green
Journal:  Prog Cardiovasc Dis       Date:  2014-08-12       Impact factor: 8.194

4.  Position Statement of the Brazilian Cardiology Society and the Brazilian Society of Hemodynamics and Interventional Cardiology on Training Centers and Professional Certification in Hemodynamics and Interventional Cardiology - 2020.

Authors:  José Airton de Arruda; Viviana de Mello Guzzo Lemke; José Mariani Júnior; Adriano Henrique Pereira Barbosa; Alexandre Schaan de Quadros; Carlos Augusto Cardoso Pedra; Cristiano de Oliveira Cardoso; Ênio Eduardo Guérios; Henrique Barbosa Ribeiro; Luiz Antonio Gubolino; Maurício Cavalieri Machado; Mauricio Jaramillo Hincapie; Nelson Antonio Moura de Araujo; Raul Ivo Rossi Filho; Ricardo Alves da Costa; Silvio Gioppato
Journal:  Arq Bras Cardiol       Date:  2020-01       Impact factor: 2.000

Review 5.  Vascular Imaging Before Transcatheter Aortic Valve Replacement (TAVR): Why and How?

Authors:  Damiano Caruso; Russell D Rosenberg; Carlo N De Cecco; Stefanie Mangold; Julian L Wichmann; Akos Varga-Szemes; Daniel H Steinberg; Andrea Laghi; U Joseph Schoepf
Journal:  Curr Cardiol Rep       Date:  2016-02       Impact factor: 2.931

6.  Cardiac rehabilitation and mid-term follow-up after transcatheter aortic valve implantation.

Authors:  Renzo Zanettini; Gemma Gatto; Ileana Mori; Maria Beatrice Pozzoni; Stefano Pelenghi; Luigi Martinelli; Silvio Klugmann
Journal:  J Geriatr Cardiol       Date:  2014-12       Impact factor: 3.327

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.