Literature DB >> 24834408

Noninvasive pressure difference mapping derived from 4D flow MRI in patients with unrepaired and repaired aortic coarctation.

Fabian Rengier1, Michael Delles1, Joachim Eichhorn1, Yoo-Jin Azad1, Hendrik von Tengg-Kobligk1, Julia Ley-Zaporozhan1, Rüdiger Dillmann1, Hans-Ulrich Kauczor1, Roland Unterhinninghofen1, Sebastian Ley1.   

Abstract

PURPOSE: To develop a method for computing and visualizing pressure differences derived from time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and to compare pressure difference maps of patients with unrepaired and repaired aortic coarctation to young healthy volunteers.
METHODS: 4D flow MRI data of four patients with aortic coarctation either before or after repair (mean age 17 years, age range 3-28, one female, three males) and four young healthy volunteers without history of cardiovascular disease (mean age 24 years, age range 20-27, one female, three males) was acquired using a 1.5-T clinical MR scanner. Image analysis was performed with in-house developed image processing software. Relative pressures were computed based on the Navier-Stokes equation.
RESULTS: A standardized method for intuitive visualization of pressure difference maps was developed and successfully applied to all included patients and volunteers. Young healthy volunteers exhibited smooth and regular distribution of relative pressures in the thoracic aorta at mid systole with very similar distribution in all analyzed volunteers. Patients demonstrated disturbed pressures compared to volunteers. Changes included a pressure drop at the aortic isthmus in all patients, increased relative pressures in the aortic arch in patients with residual narrowing after repair, and increased relative pressures in the descending aorta in a patient after patch aortoplasty.
CONCLUSIONS: Pressure difference maps derived from 4D flow MRI can depict alterations of spatial pressure distribution in patients with repaired and unrepaired aortic coarctation. The technique might allow identifying pathophysiological conditions underlying complications after aortic coarctation repair.

Entities:  

Keywords:  Aorta; aortic coarctation; magnetic resonance imaging (MRI); pressure difference mapping; three-dimensional imaging

Year:  2014        PMID: 24834408      PMCID: PMC3996241          DOI: 10.3978/j.issn.2223-3652.2014.03.03

Source DB:  PubMed          Journal:  Cardiovasc Diagn Ther        ISSN: 2223-3652


  16 in total

1.  Predictive value of mild, residual descending aortic narrowing for blood pressure and vascular damage in patients after repair of aortic coarctation.

Authors:  Joris W J Vriend; Aeiko H Zwinderman; Eric de Groot; John J P Kastelein; Berto J Bouma; Barbara J M Mulder
Journal:  Eur Heart J       Date:  2004-11-30       Impact factor: 29.983

2.  Risk factors for aortic complications in adults with coarctation of the aorta.

Authors:  Jose Maria Oliver; Pastora Gallego; Ana Gonzalez; Angel Aroca; Monserrat Bret; Jose Maria Mesa
Journal:  J Am Coll Cardiol       Date:  2004-10-19       Impact factor: 24.094

Review 3.  [Coarctation of the aorta and its surgical treatment].

Authors:  F Tronc; A Curtil; J Robin; J Ninet; G Champsaur
Journal:  Arch Mal Coeur Vaiss       Date:  1997-12

4.  Increased stiffness and persistent narrowing of the aorta after successful repair of coarctation of the aorta: relationship to left ventricular mass and blood pressure at rest and with exercise.

Authors:  C M Ong; C E Canter; F R Gutierrez; D R Sekarski; D R Goldring
Journal:  Am Heart J       Date:  1992-06       Impact factor: 4.749

5.  Endovascular stents for coarctation of the aorta: initial results and intermediate-term follow-up.

Authors:  M A Hamdan; S Maheshwari; J T Fahey; W E Hellenbrand
Journal:  J Am Coll Cardiol       Date:  2001-11-01       Impact factor: 24.094

6.  Vascular dysfunction after repair of coarctation of the aorta: impact of early surgery.

Authors:  M de Divitiis; C Pilla; M Kattenhorn; M Zadinello; A Donald; P Leeson; S Wallace; A Redington; J E Deanfield
Journal:  Circulation       Date:  2001-09-18       Impact factor: 29.690

7.  Aortic aneurysms remain a significant source of morbidity and mortality after use of Dacron(®) patch aortoplasty to repair coarctation of the aorta: results from a single center.

Authors:  Jonathan W Cramer; Salil Ginde; Peter J Bartz; James S Tweddell; S Bert Litwin; Michael G Earing
Journal:  Pediatr Cardiol       Date:  2012-07-28       Impact factor: 1.655

8.  Results after repair of coarctation of the aorta beyond infancy: a 10 to 28 year follow-up with particular reference to late systemic hypertension.

Authors:  P M Clarkson; M R Nicholson; B G Barratt-Boyes; J M Neutze; R M Whitlock
Journal:  Am J Cardiol       Date:  1983-05-15       Impact factor: 2.778

9.  More than thirty-five years of coarctation repair. An unexpected high relapse rate.

Authors:  A P Kappetein; A H Zwinderman; A J Bogers; J Rohmer; H A Huysmans
Journal:  J Thorac Cardiovasc Surg       Date:  1994-01       Impact factor: 5.209

10.  Transverse arch hypoplasia predisposes to aneurysm formation at the repair site after patch angioplasty for coarctation of the aorta.

Authors:  J Bogaert; M Gewillig; F Rademakers; H Bosmans; J Verschakelen; W Daenen; A L Baert
Journal:  J Am Coll Cardiol       Date:  1995-08       Impact factor: 24.094

View more
  4 in total

1.  Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers.

Authors:  Fabian Rengier; Michael Delles; Joachim Eichhorn; Yoo-Jin Azad; Hendrik von Tengg-Kobligk; Julia Ley-Zaporozhan; Rüdiger Dillmann; Hans-Ulrich Kauczor; Roland Unterhinninghofen; Sebastian Ley
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-03       Impact factor: 2.357

Review 2.  Unravelling cardiovascular disease using four dimensional flow cardiovascular magnetic resonance.

Authors:  Vivian P Kamphuis; Jos J M Westenberg; Roel L F van der Palen; Nico A Blom; Albert de Roos; Rob van der Geest; Mohammed S M Elbaz; Arno A W Roest
Journal:  Int J Cardiovasc Imaging       Date:  2016-11-25       Impact factor: 2.357

3.  Predictors of aortic dilation in patients with coarctation of the aorta: evaluation with dual-source computed tomography.

Authors:  Qin Zhao; Ke Shi; Zhi-Gang Yang; Kai-Yue Diao; Hua-Yan Xu; Xi Liu; Ying-Kun Guo
Journal:  BMC Cardiovasc Disord       Date:  2018-06-22       Impact factor: 2.298

4.  Patient-Adaptive Magnetic Resonance Oximetry: Comparison With Invasive Catheter Measurement of Blood Oxygen Saturation in Patients With Cardiovascular Disease.

Authors:  Juliet Varghese; Matthew Smyke; Yue Pan; Saurabh Rajpal; Jason Craft; Lee C Potter; Subha V Raman; Rizwan Ahmad; Orlando P Simonetti
Journal:  J Magn Reson Imaging       Date:  2020-05-01       Impact factor: 4.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.