Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

Paula C Charlton1, Benjamin F Mentiplay1, Yong-Hao Pua2, Ross A Clark3.   

Abstract

OBJECTIVES: Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion.
DESIGN: Intra-tester reliability with concurrent validity.
METHODS: Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used.
RESULTS: The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71).
CONCLUSIONS: Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability.
Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Keywords:  Android; Groin; Injury screening; Joint angle; Phone

Mesh:

Year:  2014        PMID: 24831757     DOI: 10.1016/j.jsams.2014.04.008

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  19 in total

1.  Viability of Hand and Wrist Photogoniometry.

Authors:  Clifton G Meals; Rebecca J Saunders; Sameer Desale; Kenneth R Means
Journal:  Hand (N Y)       Date:  2017-04-09

Review 2.  Wearable Inertial Sensor Systems for Lower Limb Exercise Detection and Evaluation: A Systematic Review.

Authors:  Martin O'Reilly; Brian Caulfield; Tomas Ward; William Johnston; Cailbhe Doherty
Journal:  Sports Med       Date:  2018-05       Impact factor: 11.136

3.  Lower extremity range of motion and alignment: A reliability and concurrent validity study of goniometric and three-dimensional motion analysis measurement.

Authors:  Viktor Ore; Salmir Nasic; Jacques Riad
Journal:  Heliyon       Date:  2020-08-25

4.  REHABILITATION AFTER HIP ARTHROSCOPY AND LABRAL REPAIR IN A HIGH SCHOOL FOOTBALL ATHLETE: A 3.6 YEAR FOLLOW-UP WITH INSIGHT INTO POTENTIAL RISK FACTORS.

Authors:  Scott W Cheatham; Morey J Kolber
Journal:  Int J Sports Phys Ther       Date:  2015-08

5.  THE IMMEDIATE EFFECTS OF A TOTAL MOTION RELEASE® WARM-UP ON ACTIVE ROTATIONAL HIP RANGE OF MOTION IN OVERHEAD ATHLETES.

Authors:  R Ross Dexter; Treylan K Loftis; Adrian N Pettaway; Russell T Baker; James May
Journal:  Int J Sports Phys Ther       Date:  2019-12

6.  Accuracy and repeatability of smartphone sensors for measuring shank-to-vertical angle.

Authors:  Brandon T Nguyen; Nick A Baicoianu; Darrin B Howell; Keshia M Peters; Katherine M Steele
Journal:  Prosthet Orthot Int       Date:  2020-04-21       Impact factor: 1.895

7.  The effect of Graston technique on the pain and range of motion in patients with chronic low back pain.

Authors:  Jeong-Hoon Lee; Dong-Kyu Lee; Jae-Seop Oh
Journal:  J Phys Ther Sci       Date:  2016-06-28

Review 8.  Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception.

Authors:  Quentin Mourcou; Anthony Fleury; Bruno Diot; Céline Franco; Nicolas Vuillerme
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

9.  Smartphone and Universal Goniometer for Measurement of Elbow Joint Motions: A Comparative Study.

Authors:  Behnam Behnoush; Nasim Tavakoli; Elham Bazmi; Fariborz Nateghi Fard; Mohammad Hossein Pourgharib Shahi; Arash Okazi; Tahmineh Mokhtari
Journal:  Asian J Sports Med       Date:  2016-06-11

10.  Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

Authors:  Russell R Russo; Matthew B Burn; Sabir K Ismaily; Brayden J Gerrie; Shuyang Han; Jerry Alexander; Christopher Lenherr; Philip C Noble; Joshua D Harris; Patrick C McCulloch
Journal:  J Exp Orthop       Date:  2017-09-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.