Literature DB >> 24817765

Impact of Analog IC Impairments in SiPM Interface Electronics.

Samrat Dey1, Thomas K Lewellen2, Robert S Miyaoka2, Jacques C Rudell1.   

Abstract

The recent realization of Silicon Photomultiplier (SiPM) devices as solid-state detectors for Positron Emission Tomography holds the promise of improving image resolution, integrating a significant portion of the interface electronics, and potentially lowering the power consumption. Our lab has previously reported on novel board-level readout electronics for an 8×8 silicon photomultiplier (SiPM) array featuring row/column summation technique to reduce the hardware requirements for signal processing and is currently working on taking the next step by implementing a monolithic CMOS chip which is based on the row-column architecture. To date, relatively little modeling has been done to understand the impact of analog non-idealities associated with the front-end electronics, on SiPM-based PET systems. This paper focuses on various analog impairments associated with PET scanner readout electronics. Matlab was used as a simulation platform to model the noise, linearity and signal bandwidth of the frontend electronics with the measured SiPM pulses as the input.

Entities:  

Year:  2012        PMID: 24817765      PMCID: PMC4013097          DOI: 10.1109/NSSMIC.2012.6551818

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  4 in total

1.  Evolution of the Design of a Second Generation FireWire Based Data Acquisition System.

Authors:  T K Lewellen; R S Miyaoka; L R Macdonald; M Haselman; D Dewitt; S Hauck
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

2.  An 8×8 Row-Column Summing Readout Electronics for Preclinical Positron Emission Tomography Scanners.

Authors:  Y C Shih; F W Sun; L R Macdonald; B P Otis; R S Miyaoka; W McDougald; T K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

3.  Design and Characteristics of a Multichannel Front-End ASIC Using Current-Mode CSA for Small-Animal PET Imaging.

Authors:  N Ollivier-Henry; N A Mbow; D Brasse; B Humbert; C Hu-Guo; C Colledani
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2011-02       Impact factor: 3.833

4.  A CMOS ASIC Design for SiPM Arrays.

Authors:  Samrat Dey; Lushon Banks; Shaw-Pin Chen; Wenbin Xu; Thomas K Lewellen; Robert S Miyaoka; Jacques C Rudell
Journal:  IEEE Trans Nucl Sci       Date:  2011-12       Impact factor: 1.679

  4 in total
  1 in total

1.  A CMOS Front-End Interface ASIC for SiPM-based Positron Emission Tomography Imaging Systems.

Authors:  Samrat Dey; Jacques C Rudell; Thomas K Lewellen; Robert S Miyaoka
Journal:  IEEE Biomed Circuits Syst Conf       Date:  2018-03-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.