PURPOSE: The purpose of this study was to provide a comprehensive quantitative analysis of capsular thickness adjacent to the acetabular rim in clinically relevant locations. METHODS: Dissections were performed and hip capsular measurements were recorded on 13 non-paired, fresh-frozen cadaveric hemi-pelvises using a coordinate measuring device. Measurements were taken for each clock-face position at 0, 5, 10 and 15 mm distances from the labral edge. RESULTS: The capsule was consistently thickest at 2 o'clock for each interval from the labrum with a maximum thickness of 8.3 at 10 mm [95 % CI 6.8, 9.8] and 15 mm [95 % CI 6.8, 9.7]. The capsule was noticeably thinner between 4 and 11 o'clock with a minimum thickness of 4.1 mm [95 % CI 3.3, 4.9] at 10 o'clock at the labral edge. Direct comparison between 0 and 5 mm between 9 and 3 o'clock showed that the hip capsule was significantly thicker at 5 mm from the labrum at 9 o'clock (p = 0.027), 10 o'clock (p = 0.032), 1 o'clock (p = 0.003), 2 o'clock (p = 0.001) and 3 o'clock (p = 0.001). CONCLUSIONS: The hip capsule was thickest between the 1 and 2 o'clock positions for all measured distances from the acetabular labrum and reached its maximum thickness at 2 o'clock, which corresponds to the location of the iliofemoral ligament.
PURPOSE: The purpose of this study was to provide a comprehensive quantitative analysis of capsular thickness adjacent to the acetabular rim in clinically relevant locations. METHODS: Dissections were performed and hip capsular measurements were recorded on 13 non-paired, fresh-frozen cadaveric hemi-pelvises using a coordinate measuring device. Measurements were taken for each clock-face position at 0, 5, 10 and 15 mm distances from the labral edge. RESULTS: The capsule was consistently thickest at 2 o'clock for each interval from the labrum with a maximum thickness of 8.3 at 10 mm [95 % CI 6.8, 9.8] and 15 mm [95 % CI 6.8, 9.7]. The capsule was noticeably thinner between 4 and 11 o'clock with a minimum thickness of 4.1 mm [95 % CI 3.3, 4.9] at 10 o'clock at the labral edge. Direct comparison between 0 and 5 mm between 9 and 3 o'clock showed that the hip capsule was significantly thicker at 5 mm from the labrum at 9 o'clock (p = 0.027), 10 o'clock (p = 0.032), 1 o'clock (p = 0.003), 2 o'clock (p = 0.001) and 3 o'clock (p = 0.001). CONCLUSIONS: The hip capsule was thickest between the 1 and 2 o'clock positions for all measured distances from the acetabular labrum and reached its maximum thickness at 2 o'clock, which corresponds to the location of the iliofemoral ligament.
Authors: Jacob M Elkins; Nicholas J Stroud; M James Rudert; Yuki Tochigi; Douglas R Pedersen; Benjamin J Ellis; John J Callaghan; Jeffrey A Weiss; Thomas D Brown Journal: J Orthop Res Date: 2011-04-14 Impact factor: 3.494
Authors: Matthew V Smith; Ryan S Costic; Robert Allaire; Peter L Schilling; Jon K Sekiya Journal: Knee Surg Sports Traumatol Arthrosc Date: 2012-10-30 Impact factor: 4.342
Authors: Casey A Myers; Bradley C Register; Pisit Lertwanich; Leandro Ejnisman; W Wes Pennington; J Erik Giphart; Robert F LaPrade; Marc J Philippon Journal: Am J Sports Med Date: 2011-07 Impact factor: 6.202