Efficacy of real-time continuous glucose monitoring on glycaemic control and glucose variability in type 1 diabetic patients treated with either insulin pumps or multiple insulin injection therapy: a randomized controlled crossover trial.

Andrea Tumminia1, Salvatore Crimi, Laura Sciacca, Massimo Buscema, Lucia Frittitta, Sebastiano Squatrito, Riccardo Vigneri, Letizia Tomaselli.   

Abstract

BACKGROUND: The aim of this study was to determine the efficacy of real-time continuous glucose monitoring in T1D patients treated with insulin pump therapy or multiple daily insulin therapy.
METHODS: Twenty adult patients (ten insulin pump therapy and ten multiple daily insulin) with poor glycaemic control (HbA1c  > 8.0%) were randomized into two groups for 6 months: the continuous glucose monitoring arm (using real-time continuous glucose monitoring) and the SMBG arm. After 2 months of wash-out, the participants crossed over. The primary outcome was HbA1c reduction. The secondary outcomes were hypoglycaemia and hyperglycaemia risk assessment (area under the curve < 70 mg/dL/day and AUC > 200 mg/dL/day, respectively) and glucose variability.
RESULTS: Fourteen patients (eight multiple daily insulin, six insulin pump therapy) used continuous glucose monitoring appropriately (at least 40% of the time). In these patients, the improvement in glycaemic control was more evident during the real-time continuous glucose monitoring period (7.76% ± 0.4 vs 8.54% ± 0.4, p < 0.05) than during the self-monitoring of blood glucose period (8.42% ± 0.4 vs 8.56% ± 0.5, p = 0.2). Better results with continuous glucose monitoring were observed in patients using multiple daily insulin with greater improvement in both glycaemic control (7.71% ± 0.2 vs 8.58% ± 0.2, p < 0.05) and glucose variability and with a marked reduction in the risk of both hypoglycaemia and hyperglycaemia.
CONCLUSIONS: Appropriate use of real-time continuous glucose monitoring improved glycometabolic control in T1D patients. The effects of continuous glucose monitoring were more evident in patients under multiple daily insulin treatment, compared with insulin pump therapy. Glucose variability, in addition to glycaemic control, was improved in compliant diabetic patients.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  CSII; SMBG; T1D; glucose variability; real-time CGM

Mesh:

Substances:

Year:  2015        PMID: 24816997     DOI: 10.1002/dmrr.2557

Source DB:  PubMed          Journal:  Diabetes Metab Res Rev        ISSN: 1520-7552            Impact factor:   4.876


  23 in total

1.  Use of Glucose Rate of Change Arrows to Adjust Insulin Therapy Among Individuals with Type 1 Diabetes Who Use Continuous Glucose Monitoring.

Authors:  Jeremy Pettus; Steven V Edelman
Journal:  Diabetes Technol Ther       Date:  2016-02       Impact factor: 6.118

2.  Continuous Glucose Monitoring Use in Type 1 Diabetes: Longitudinal Analysis Demonstrates Meaningful Improvements in HbA1c and Reductions in Health Care Utilization.

Authors:  Christopher G Parkin; Claudia Graham; John Smolskis
Journal:  J Diabetes Sci Technol       Date:  2017-02-01

3.  Help when you need it: Perspectives of adults with T1D on the support and training they would have wanted when starting CGM.

Authors:  Molly L Tanenbaum; Laurel H Messer; Christine A Wu; Marina Basina; Bruce A Buckingham; Danielle Hessler; Shelagh A Mulvaney; David M Maahs; Korey K Hood
Journal:  Diabetes Res Clin Pract       Date:  2021-09-14       Impact factor: 8.180

4.  Continuous Intravenous versus Subcutaneous Administration of Insulin for Glycemic Variability in Acute Ischemic Stroke.

Authors:  Lin-Zhe Du; Pei-Yan Liu; Chen-Yan Ge; Yang Li; Yuan-Yuan Li; Mu-Fei Tang; Jin-Jin Chen
Journal:  Neuropsychiatr Dis Treat       Date:  2022-07-01       Impact factor: 2.989

Review 5.  Diabetes: the role of continuous glucose monitoring.

Authors:  Julianna Rivich Kluemper; Alexandria Smith; Brooke Wobeter
Journal:  Drugs Context       Date:  2022-06-14

Review 6.  Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis.

Authors:  Evelyn Teo; Norasyikin Hassan; Wilson Tam; Serena Koh
Journal:  Diabetologia       Date:  2022-02-09       Impact factor: 10.460

7.  Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM).

Authors:  Jeremy Pettus; Steven V Edelman
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

8.  Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials.

Authors:  I Dicembrini; C Cosentino; M Monami; E Mannucci; L Pala
Journal:  Acta Diabetol       Date:  2020-08-13       Impact factor: 4.280

Review 9.  Integrated insulin pump therapy with continuous glucose monitoring for improved adherence: technology update.

Authors:  Andrea Tumminia; Laura Sciacca; Lucia Frittitta; Sebastiano Squatrito; Riccardo Vigneri; Rosario Le Moli; Letizia Tomaselli
Journal:  Patient Prefer Adherence       Date:  2015-09-07       Impact factor: 2.711

10.  Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2018-02-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.