Literature DB >> 24814964

Relationship between halo size and forward light scatter.

María C Puell1, María J Pérez-Carrasco1, Catalina Palomo-Alvarez1, Beatriz Antona1, Ana Barrio1.   

Abstract

PURPOSE: To determine the relationship between the size of a halo induced by a glare source and forward scatter or visual acuity (VA) in healthy eyes.
METHOD: Measurements were made in the right eyes of 51 healthy individuals of mean age 29.3 ± 7.5 years. Halo radius was measured using the Vision Monitor and low luminance (1 cd/m(2)) optotypes presented at a distance of 2.5 m. The visual angle subtended by the radius of the halo was calculated in minutes of arc (arc min). Forward scatter or, straylight, was measured using the compensation comparison technique. Best-corrected distance VA was measured using high contrast (HC) (96%) and low contrast (LC) (10%) Bailey-Lovie logMAR letter charts under photopic (85 cd/m(2)) and mesopic (0.15 cd/m(2)) luminance conditions.
RESULTS: Mean halo radius was 202 ± 43 arc min (3.4 ± 0.7°) and mean retinal straylight was 0.95 ± 0.12 log units. Mean photopic distance HC-VA and LC-VA were -0.02 ± 0.06 and 0.12 ± 0.09 logMAR, respectively. Mean mesopic distance HC-VA and LC-VA were 0.35 ± 0.11 and 0.74 ± 0.11 logMAR, respectively. Forward stepwise regression analysis revealed that halo radius was significantly correlated with straylight (r=0.45) and mesopic LC-VA (r=0.48), but not with photopic HC-VA and/or LC-VA and mesopic HC-VA.
CONCLUSIONS: In healthy eyes, the larger the halo size induced by a given glare source, the greater the forward-scatter (straylight) and worse the mesopic LC-VA. Halo size seems to be independent of photopic HC-VA or LC-VA and mesopic HC-VA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

Entities:  

Keywords:  Psychophysics; Vision

Mesh:

Year:  2014        PMID: 24814964     DOI: 10.1136/bjophthalmol-2014-304872

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  5 in total

1.  Evaluation of disk halo size after small incision lenticule extraction (SMILE).

Authors:  Tian Han; Feng Zhao; Xun Chen; Huamao Miao; Zhuoyi Chen; Xingtao Zhou
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-10-29       Impact factor: 3.117

2.  Evaluation of Disk Halo Size and Identification of Correlated Factors in Myopic Adults.

Authors:  Wuxiao Zhao; Jing Zhao; Tian Han; Meng Li; Jifang Wang; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2022-01-28

3.  A Comprehensive Investigation of Contrast Sensitivity and Disk Halo in High Myopia Treated With SMILE and EVO Implantable Collamer Lens Implantation.

Authors:  Wuxiao Zhao; Jing Zhao; Tian Han; Jifang Wang; Zhe Zhang; Xingtao Zhou
Journal:  Transl Vis Sci Technol       Date:  2022-04-01       Impact factor: 3.048

4.  Minimum pupil in pupillary response to light and myopia affect disk halo size: a cross-sectional study.

Authors:  Feng Zhao; Tian Han; Xun Chen; Zhi Chen; Ke Zheng; Xiaoying Wang; Xingtao Zhou
Journal:  BMJ Open       Date:  2018-04-10       Impact factor: 2.692

5.  Relationships Between Haloes and Objective Visual Quality in Healthy Eyes.

Authors:  Lu Yao; Ye Xu; Tian Han; Linsong Qi; Jiumei Shi; Zhikang Zou; Xingtao Zhou
Journal:  Transl Vis Sci Technol       Date:  2020-09-11       Impact factor: 3.283

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.