Literature DB >> 24810736

Automatic detection of the carotid lumen axis in B-mode ultrasound images.

Rui Rocha1, Jorge Silva2, Aurélio Campilho2.   

Abstract

A new approach is introduced for the automatic detection of the lumen axis of the common carotid artery in B-mode ultrasound images. The image is smoothed using a Gaussian filter and then a dynamic programming scheme extracts the dominant paths of local minima of the intensity and the dominant paths of local maxima of the gradient magnitude with the gradient pointing downwards. Since these paths are possible estimates of the lumen axis and the far wall of a blood vessel, respectively, they are grouped together into pairs. Then, a pattern of two features is computed from each pair of paths and used as input to a linear discriminant classifier in order to select the pair of paths that correspond to the common carotid artery. The estimated lumen axis is the path of local minima of the intensity that belongs to the selected pair of paths. The proposed method is suited to real time processing, no user interaction is required and the number of parameters is minimal and easy to determine. The validation was performed using two datasets, with a total of 199 images, and has shown a success rate of 99.5% (100% if only the carotid regions for which a ground truth is available are considered). The datasets have a large diversity of images, including cases of arteries with plaque and images with heavy noise, text or other graphical markings inside the artery region.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Keywords:  Carotid; Classification; Dynamic programming; Image segmentation; Lumen axis; Ultrasound image

Mesh:

Year:  2014        PMID: 24810736     DOI: 10.1016/j.cmpb.2014.04.004

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  5 in total

1.  Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches.

Authors:  Tadashi Araki; P Krishna Kumar; Harman S Suri; Nobutaka Ikeda; Ajay Gupta; Luca Saba; Jeny Rajan; Francesco Lavra; Aditya M Sharma; Shoaib Shafique; Andrew Nicolaides; John R Laird; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-06-14       Impact factor: 4.460

2.  Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach.

Authors:  P Krishna Kumar; Tadashi Araki; Jeny Rajan; Luca Saba; Francesco Lavra; Nobutaka Ikeda; Aditya M Sharma; Shoaib Shafique; Andrew Nicolaides; John R Laird; Ajay Gupta; Jasjit S Suri
Journal:  Med Biol Eng Comput       Date:  2016-12-10       Impact factor: 2.602

3.  Effect of Watermarking on Diagnostic Preservation of Atherosclerotic Ultrasound Video in Stroke Telemedicine.

Authors:  Nilanjan Dey; Soumyo Bose; Achintya Das; Sheli Sinha Chaudhuri; Luca Saba; Shoaib Shafique; Andrew Nicolaides; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-02-10       Impact factor: 4.460

4.  A review of ultrasound common carotid artery image and video segmentation techniques.

Authors:  Christos P Loizou
Journal:  Med Biol Eng Comput       Date:  2014-10-05       Impact factor: 2.602

5.  Automatic Lumen Detection on Longitudinal Ultrasound B-Mode Images of the Carotid Using Phase Symmetry.

Authors:  José Rouco; Elsa Azevedo; Aurélio Campilho
Journal:  Sensors (Basel)       Date:  2016-03-09       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.