Literature DB >> 24802025

Analysis of xylene in aqueous media using needle-trap microextraction with a carbon nanotube sorbent.

Sara Karimi Zeverdegani1, Abdulrahman Bahrami, Masoud Rismanchian, Farshid Ghorbani Shahna.   

Abstract

This paper describes a new extraction technique with needles and a sorbent based on carbon nanotubes to analyze trace amounts of three isomers of xylenes in aqueous samples. In this research, results have been compared with one commercial sorbent. The synthesized sorbent was prepared using sol-gel technology and was packed into 20 gauge needles, and the same size needle was used for packing the commercial sorbent. In the extraction process, a purge and trap sampling methodology is developed, so purging and trapping cycles were performed by a sampling pump. Optimized conditions for standard xylene samples have been obtained, and eight urine samples from workers that were exposed to xylene in the workplace were collected and analyzed. Experimental parameters such as limits of detection and quantification were investigated, and these two parameters were <1 μg/L.
© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Carbon nanotubes; Extraction; Sol-gel process; Sorbents

Mesh:

Substances:

Year:  2014        PMID: 24802025     DOI: 10.1002/jssc.201400262

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

1.  Analysis of formaldehyde and acrolein in the aqueous samples using a novel needle trap device containing nanoporous silica aerogel sorbent.

Authors:  Abdullah Barkhordari; Mansour R Azari; Rezvan Zendehdel; Mahmoud Heidari
Journal:  Environ Monit Assess       Date:  2017-03-20       Impact factor: 2.513

2.  Urinary bio-monitoring of amphetamine derivatives by needle trap device packed with the zirconium-based metal-organic framework.

Authors:  Razzagh Rahimpoor; Ali Firoozichahak; Saber Alizadeh; Davood Nematollahi
Journal:  Sci Rep       Date:  2022-08-11       Impact factor: 4.996

3.  Fluorescence and photophysical properties of xylene isomers in water: with experimental and theoretical approaches.

Authors:  Muhammad Farooq Saleem Khan; Jing Wu; Bo Liu; Cheng Cheng; Mona Akbar; Yidi Chai; Aisha Memon
Journal:  R Soc Open Sci       Date:  2018-02-07       Impact factor: 2.963

4.  Determination of halogenated hydrocarbons in urine samples using a needle trap device packed with Ni/Zn-BTC bi-MMOF via the dynamic headspace method.

Authors:  Razzagh Rahimpoor; Ali Firoozichahak; Davood Nematollahi; Saber Alizadeh; Parsa Mohammad Alizadeh; Ali Akbar Alinaghi Langari
Journal:  RSC Adv       Date:  2021-06-17       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.