Urinary bio-monitoring of amphetamine derivatives by needle trap device packed with the zirconium-based metal-organic framework.

Razzagh Rahimpoor1, Ali Firoozichahak2, Saber Alizadeh3, Davood Nematollahi4.   

Abstract

In this research, zirconium-based metal-organic framework was utilized as a novel and efficient porous adsorbent for headspace extraction of Amphetamine, Methamphetamine, and Fenfluramine from the urine samples by a needle trap device (NTD). The Zr-UiO-66-PDC was electrosynthesized at the green conditions and characterized by various analyses such as FT-IR, XRD, FE-SEM, EDS, and elemental mapping techniques. Then, the effective parameters on the NTD efficiency such as salt content, pH, extraction/desorption temperature and time were evaluated and optimized by response surface methodology. The optimal extraction of amphetamine compounds was accomplished in 50 min at 70 ºC at the situation with NaCl content of 27% and pH: 11.90. The limit of detection, and limit of quantification factors were determined to be 0.06-0.09 and 0.5-0.8 ng mL-1, respectively. Furthermore, the precision and accuracy (intra- and inter-day) of the employed procedure in the term of relative standard deviation (RSD) were calculated in the range of 8.0-9.0% and 6.8-9.8%, respectively. Also, the recovery percent of the extracted analytes were concluded in the range of 95.0-97.0% after 10 days from the sampling and storage at 4 °C. Finally, the proposed procedure was involved in the analysis of amphetamine compounds in the real urine samples. These results were proved the proposed Zr-UiO-66-PDC@HS-NTD technique coupled with GC-FID can be used as an eco-friendly, fast-response, sensitive, and efficient drug test procedure for trace analysis of the amphetamine compounds in urine samples.
© 2022. The Author(s).

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35953701      PMCID: PMC9372183          DOI: 10.1038/s41598-022-17861-1

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.996


  33 in total

1.  Highly sensitive analysis of methamphetamine and amphetamine in human whole blood using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

Authors:  K Okajima; A Namera; M Yashiki; I Tsukue; T Kojima
Journal:  Forensic Sci Int       Date:  2001-02-01       Impact factor: 2.395

2.  Determination of amphetamine and methamphetamine in serum via headspace derivatization solid-phase microextraction-gas chromatography-mass spectrometry.

Authors:  M R Lee; Y S Song; B H Hwang; C C Chou
Journal:  J Chromatogr A       Date:  2000-10-27       Impact factor: 4.759

3.  Rapid analysis of amphetamine, methamphetamine, MDA, and MDMA in urine using solid-phase microextraction, direct on-fiber derivatization, and analysis by GC-MS.

Authors:  C Jurado; M P Giménez; T Soriano; M Menéndez; M Repetto
Journal:  J Anal Toxicol       Date:  2000 Jan-Feb       Impact factor: 3.367

4.  Determination of amphetamine, methamphetamine and dimethamphetamine in human urine by solid-phase microextraction (SPME)-gas chromatography/mass spectrometry.

Authors:  S W Myung; H K Min; S Kim; M Kim; J B Cho; T J Kim
Journal:  J Chromatogr B Biomed Sci Appl       Date:  1998-09-25

5.  Application of a new nanocarbonaceous sorbent in electromembrane surrounded solid phase microextraction for analysis of amphetamine and methamphetamine in human urine and whole blood.

Authors:  Maryam Rezazadeh; Yadollah Yamini; Shahram Seidi
Journal:  J Chromatogr A       Date:  2015-04-04       Impact factor: 4.759

Review 6.  Extraction media used in needle trap devices-Progress in development and application.

Authors:  Kamila Kędziora; Wiesław Wasiak
Journal:  J Chromatogr A       Date:  2017-05-12       Impact factor: 4.759

7.  Rapid and Low-Cost Electrochemical Synthesis of UiO-66-NH2 with Enhanced Fluorescence Detection Performance.

Authors:  Jin-Zhi Wei; Fu-Xin Gong; Xiao-Jun Sun; Ye Li; Ting Zhang; Xue-Jing Zhao; Feng-Ming Zhang
Journal:  Inorg Chem       Date:  2019-04-26       Impact factor: 5.165

8.  A new mixed mode solid phase extraction strategy for opioids, cocaines, amphetamines and adulterants in human blood with hybrid liquid chromatography tandem mass spectrometry detection.

Authors:  Geraldine Dowling; Liam Regan
Journal:  J Pharm Biomed Anal       Date:  2010-12-08       Impact factor: 3.935

9.  Molecularly imprinted polymer-sol-gel tablet toward micro-solid phase extraction: II. Determination of amphetamine in human urine samples by liquid chromatography-tandem mass spectrometry.

Authors:  Aziza El-Beqqali; Lars I Andersson; Amin Dadoun Jeppsson; Mohamed Abdel-Rehim
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2017-08-26       Impact factor: 3.205

10.  Determination of amphetamines in human urine by headspace solid-phase microextraction and gas chromatography.

Authors:  Nikolaos Raikos; Klio Christopoulou; Georgios Theodoridis; Heleni Tsoukali; Dimitrios Psaroulis
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2003-06-05       Impact factor: 3.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.