Does cone beam computed tomography-derived bone density give predictable data about stability changes of immediately loaded implants?: A 1-year resonance frequency follow-up study.

Ufuk Tatli1, Fariz Salimov, Mehmet Kürkcü, Mücahide Akoğlan, Cem Kurtoğlu.   

Abstract

The aim of this clinical study was to evaluate whether preoperative bone density value derived from cone-beam computed tomography (CBCT) gives predictable data about primary and secondary stability characteristics of immediately loaded dental implants under different clinical variables. A total of 77 immediately loaded implants placed in 23 patients were included the study. Bone density values of the implant recipient sites were recorded using CBCT. The maximum insertion torque values (ITVs) of the implants were recorded using a digital torque meter during surgery. Resonance frequency measurements were taken using the Osstell Mentor at 4 time points; immediately after surgery (implant stability quotient [ISQ]0) and after 1 (ISQ1), 3 months (ISQ3), and 12 months (ISQ12) of loading. Data were analyzed statistically. The mean bone density and ITVs of all implants were 565 ± 81 and 36.8 ± 3.8 N · cm, respectively. The mean ISQ values were 73.6 ± 5.8 at baseline, 71.1 ± 6.5 after 1 month, 74.8 ± 5.6 after 3 months, and 76.6 ± 5.1 after 12 months of loading. Statistically significant differences were observed between ISQ0 and ISQ1 (P < 0.001), and ISQ0 and ISQ12 (P < 0.001), but not between ISQ0 and ISQ3 (P > 0.05). In regard to stability changes over time, statistically significant correlations were found between bone density values from CBCT and ISQ follow-up measurements, and between ITV and ISQ follow-up measurements in all examination periods. Thus, it is possible to predict primary and secondary stability characteristics of immediately loaded implants by using preoperative CBCT scan and perioperative ITV.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24799099     DOI: 10.1097/SCS.0000000000000727

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  5 in total

Review 1.  CBCT-based bone quality assessment: are Hounsfield units applicable?

Authors:  R Pauwels; R Jacobs; S R Singer; M Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

2.  Comparison of Cone Beam Computed Tomography-Derived Alveolar Bone Density Between Subjects with and without Aggressive Periodontitis.

Authors:  Mohammad S Al-Zahrani; Eman Y Elfirt; Manea M Al-Ahmari; Ibrahim A Yamany; Maher A Alabdulkarim; Khalid H Zawawi
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

4.  A Comparison between the Implant Stability Quotient and the Fractal Dimension of Alveolar Bone at the Implant Site.

Authors:  Tomasz Kulczyk; Agata Czajka-Jakubowska; Agnieszka Przystańska
Journal:  Biomed Res Int       Date:  2018-10-15       Impact factor: 3.411

5.  Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants.

Authors:  Diego Fernandes Triches; Fernando Rizzo Alonso; Luis André Mezzomo; Danilo Renato Schneider; Eduardo Aydos Villarinho; Maria Ivete Rockenbach; Eduardo Rolim Teixeira; Rosemary Sadami Shinkai
Journal:  Int J Implant Dent       Date:  2019-02-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.