Literature DB >> 24798137

Radiation exposure of abdominal cone beam computed tomography.

Anna M Sailer1, Geert Willem H Schurink, Joachim E Wildberger, Rick de Graaf, Willem H van Zwam, Michiel W de Haan, Gerrit J Kemerink, Cécile R L P N Jeukens.   

Abstract

PURPOSE: To evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT).
METHODS: This prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients' individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed.
RESULTS: Mean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1-7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients' weight (r = 0.55, slope = 0.045 mSv/kg, p < 0.001). Radiation exposure of CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight.
CONCLUSIONS: Mean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.

Entities:  

Mesh:

Year:  2014        PMID: 24798137     DOI: 10.1007/s00270-014-0900-7

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  4 in total

1.  Percutaneous nephrolithotripsy: C-arm CT with 3D virtual navigation in non-dilated renal collecting systems.

Authors:  Dechao Jiao; Zhanli Zhang; Zhanguo Sun; Yanli Wang; Xinwei Han
Journal:  Diagn Interv Radiol       Date:  2018 Jan-Feb       Impact factor: 2.630

2.  Investigations of organ and effective doses of abdominal cone-beam computed tomography during transarterial chemoembolization using Monte Carlo simulation.

Authors:  Yi-Shuan Hwang; Hui-Yu Tsai; Yu-Ying Lin; Kar-Wai Lui
Journal:  BMC Med Imaging       Date:  2018-02-05       Impact factor: 1.930

3.  Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice.

Authors:  Anna M Sailer; Leonie Paulis; Laura Vergoossen; Axel O Kovac; Geert Wijnhoven; Geert Willem H Schurink; Barend Mees; Marco Das; Joachim E Wildberger; Michiel W de Haan; Cécile R L P N Jeukens
Journal:  Cardiovasc Intervent Radiol       Date:  2016-12-09       Impact factor: 2.740

4.  Fluoroscopy with MRA fusion image guidance in endovascular iliac artery interventions: study protocol for a randomized controlled trial (3DMR-Iliac-roadmapping study).

Authors:  Seline R Goudeketting; Stefan G H Heinen; Michiel W de Haan; Anna M Sailer; Daniel A F van den Heuvel; Marco J van Strijen; Jean-Paul P M de Vries
Journal:  Trials       Date:  2018-11-01       Impact factor: 2.279

  4 in total