Literature DB >> 24795155

Evaluating dipolar source localization feasibility from intracerebral SEEG recordings.

V Caune1, R Ranta2, S Le Cam1, J Hofmanis1, L Maillard3, L Koessler1, V Louis-Dorr1.   

Abstract

Stereo-electroencephalography (SEEG) is considered as the golden standard for exploring targeted structures during pre-surgical evaluation in drug-resistant partial epilepsy. The depth electrodes, inserted in the brain, consist of several collinear measuring contacts (sensors). Clinical routine analysis of SEEG signals is performed on bipolar montage, providing a focal view of the explored structures, thus eliminating activities of distant sources that propagate through the brain volume. We propose in this paper to exploit the common reference SEEG signals. In this case, the volume propagation information is preserved and electrical source localization (ESL) approaches can be proposed. Current ESL approaches used to localize and estimate the activity of the neural generators are mainly based on surface EEG/MEG signals, but very few studies exist on real SEEG recordings, and the case of equivalent current dipole source localization has not been explored yet in this context. In this study, we investigate the influence of volume conduction model, spatial configuration of SEEG sensors and level of noise on the ESL accuracy, using a realistic simulation setup. Localizations on real SEEG signals recorded during intracerebral electrical stimulations (ICS, known sources) as well as on epileptic interictal spikes are carried out. Our results show that, under certain conditions, a straightforward approach based on an equivalent current dipole model for the source and on simple analytical volume conduction models yields sufficiently precise solutions (below 10mm) of the localization problem. Thus, electrical source imaging using SEEG signals is a promising tool for distant brain source investigation and might be used as a complement to routine visual interpretations.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dipolar source model; Electrical source imaging; Intracerebral electrical stimulations (ICS); Inverse problem; Stereo-electroencephalography (SEEG)

Mesh:

Year:  2014        PMID: 24795155     DOI: 10.1016/j.neuroimage.2014.04.058

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  6 in total

1.  Data integration: Combined imaging and electrophysiology data in the cloud.

Authors:  Lohith G Kini; Kathryn A Davis; Joost B Wagenaar
Journal:  Neuroimage       Date:  2015-06-02       Impact factor: 6.556

2.  Electrophysiological Brain Connectivity: Theory and Implementation.

Authors:  Bin He; Laura Astolfi; Pedro A Valdes-Sosa; Daniele Marinazzo; Satu Palva; Christian G Benar; Christoph M Michel; Thomas Koenig
Journal:  IEEE Trans Biomed Eng       Date:  2019-05-07       Impact factor: 4.538

3.  Electromagnetic source imaging using simultaneous scalp EEG and intracranial EEG: An emerging tool for interacting with pathological brain networks.

Authors:  Seyed Amir Hossein Hosseini; Abbas Sohrabpour; Bin He
Journal:  Clin Neurophysiol       Date:  2017-11-07       Impact factor: 3.708

4.  Characterizing the role of the structural connectome in seizure dynamics.

Authors:  Preya Shah; Arian Ashourvan; Fadi Mikhail; Adam Pines; Lohith Kini; Kelly Oechsel; Sandhitsu R Das; Joel M Stein; Russell T Shinohara; Danielle S Bassett; Brian Litt; Kathryn A Davis
Journal:  Brain       Date:  2019-07-01       Impact factor: 13.501

5.  Data-driven method to infer the seizure propagation patterns in an epileptic brain from intracranial electroencephalography.

Authors:  Viktor Sip; Meysam Hashemi; Anirudh N Vattikonda; Marmaduke M Woodman; Huifang Wang; Julia Scholly; Samuel Medina Villalon; Maxime Guye; Fabrice Bartolomei; Viktor K Jirsa
Journal:  PLoS Comput Biol       Date:  2021-02-17       Impact factor: 4.475

6.  SEEG in 3D: Interictal Source Localization From Intracerebral Recordings.

Authors:  David Satzer; Yasar T Esengul; Peter C Warnke; Naoum P Issa; Douglas R Nordli
Journal:  Front Neurol       Date:  2022-02-08       Impact factor: 4.003

  6 in total