Lars Englberger1, Thierry P Carrel2, Mirko Doss3, Jerzy Sadowski4, Krzysztof Bartus4, Friedrich F Eckstein5, Federico M Asch6, Sven Martens7. 1. Department of Cardiovascular Surgery, University Hospital Bern, Bern, Switzerland. Electronic address: lars.englberger@insel.ch. 2. Department of Cardiovascular Surgery, University Hospital Bern, Bern, Switzerland. 3. Department of Thoracic and Cardiovascular Surgery, Johann Wolfgang Goethe University, Frankfurt, Germany. 4. Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, Krakow, Poland. 5. Department of Cardiac Surgery, University Hospital Basel, Basel, Switzerland. 6. MedStar Health Research Institute, MedStar Washington Hospital Center, Washington, DC. 7. Department of Thoracic and Cardiovascular Surgery, University Hospital Muenster, Muenster, Germany.
Abstract
OBJECTIVE: Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS: Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS: The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS: The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.
OBJECTIVE: Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS: Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS: The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS: The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.
Authors: Marco Di Eusanio; Kevin Phan; Denis Bouchard; Thierry P Carrel; Otto E Dapunt; Roberto Di Bartolomeo; Harald C Eichstaedt; Theodor Fischlein; Thierry Folliguet; Borut Gersak; Mattia Glauber; Axel Haverich; Martin Misfeld; Peter J Oberwalder; Giuseppe Santarpino; Malakh Lal Shrestha; Marco Solinas; Marco Vola; Francesco Alamanni; Alberto Albertini; Gopal Bhatnagar; Michel Carrier; Stephen Clark; Federic Collart; Utz Kappert; Alfred Kocher; Bart Meuris; Carmelo Mignosa; Ahmed Ouda; Marc Pelletier; Parwis Baradaran Rahmanian; David Reineke; Kevin Teoh; Giovanni Troise; Emmanuel Villa; Thorsten Wahlers; Tristan D Yan Journal: Ann Cardiothorac Surg Date: 2015-03
Authors: Paolo Nardi; Calogera Pisano; Fabio Bertoldo; Sara Rita Vacirca; Monica Greci; Carlo Bassano; Antonio Scafuri; Antonio Pellegrino; Giovanni Ruvolo Journal: J Thorac Dis Date: 2019-04 Impact factor: 2.895
Authors: Muhammet Onur Hanedan; Mehmet Ali Yuruk; Ali Ihsan Parlar; Ugur Ziyrek; Ali Kemal Arslan; Ufuk Sayar; Ilker Mataraci Journal: Tex Heart Inst J Date: 2018-02-01
Authors: Declan Lloyd; Jessica G Y Luc; Ben Elias Indja; Vannessa Leung; Nelson Wang; Kevin Phan Journal: J Thorac Dis Date: 2019-01 Impact factor: 2.895
Authors: Krzysztof Bartus; Jerzy Sadowski; Radoslaw Litwinowicz; Grzegorz Filip; Marek Jasinski; Marek Deja; Mariusz Kusmierczyk; Szymon Pawlak; Marek Jemielity; Dariusz Jagielak; Piotr Hendzel; Piotr Suwalski; Zdzisław Tobota; Bohdan Maruszewski; Boguslaw Kapelak Journal: J Thorac Dis Date: 2019-06 Impact factor: 2.895