Free software for performing physical analysis of systems for digital radiography and mammography.

Bruno Donini1, Stefano Rivetti2, Nico Lanconelli1, Marco Bertolini3.   

Abstract

PURPOSE: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks.
METHODS: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag.
RESULTS: The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin.
CONCLUSIONS: This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online (www.medphys.it/downloads.htm). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

Entities:  

Mesh:

Year:  2014        PMID: 24784382     DOI: 10.1118/1.4870955

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  New Software for DQE Calculation in Digital Mammography Compliant with IEC 62220-1-2.

Authors:  Magdalena Dobrzyńska; Anna Wysocka-Rabin; Ewa Fabiszewska; Katarzyna Pasicz; Witold Skrzyński
Journal:  J Digit Imaging       Date:  2022-09-14       Impact factor: 4.903

2.  Application of a newly developed software program for image quality assessment in cone-beam computed tomography.

Authors:  Marcus Vinicius Linhares de Oliveira; António Carvalho Santos; Graciano Paulo; Paulo Sergio Flores Campos; Joana Santos
Journal:  Imaging Sci Dent       Date:  2017-06-22

3.  Evaluation of a pixelated large format CMOS sensor for x-ray microbeam radiotherapy.

Authors:  Samuel Flynn; Tony Price; Philip P Allport; Ileana Silvestre Patallo; Russell Thomas; Anna Subiel; Stefan Bartzsch; Franziska Treibel; Mabroor Ahmed; Jon Jacobs-Headspith; Tim Edwards; Isaac Jones; Dan Cathie; Nicola Guerrini; Iain Sedgwick
Journal:  Med Phys       Date:  2020-01-06       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.