Literature DB >> 24782457

Influence of the observer's level of experience on systolic and diastolic arterial blood pressure measurements using Doppler ultrasonography in healthy conscious cats.

Vassiliki Gouni1, Renaud Tissier2, Charlotte Misbach3, David Balouka3, Hanna Bueno3, Jean-Louis Pouchelon1, Hervé P Lefebvre4, Valérie Chetboul5.   

Abstract

The objective of this study was to determine the influence of the observer's level of experience on within- and between-day variability, and the percentage of successful systolic (SAP) and diastolic arterial blood pressure (DAP) measurements obtained by Doppler ultrasonography (DU) in awake cats. For this purpose, six healthy conscious cats were used and four observers with different levels of training performed 144 SAP and DAP measurements on 4 days using DU. Measurements were recorded five consecutive times, and mean values were used for statistical analysis. Only the two most skilled observers - a PhD student in cardiology and a Dipl ECVIM-CA (cardiology) - had within- and between-day coefficients of variation (CVs) for SAP ⩽16% (13-16%). Conversely, the two less experienced observers - a fifth-year student and an assistant - had high between-day CVs (61% and 73%). For DAP, only the most experienced observer (Dipl ECVIM-CA) succeeded in 100% of the attempts, with within- and between-day CVs of 11% and 4%, respectively. Conversely, DAP could not be measured by the other three observers in 8%, 19% and 56% of attempts (from the highest to the lowest level of experience); therefore, the corresponding CV values could not be calculated. In conclusion, SAP may be assessed using DU in healthy awake cats with good repeatability and reproducibility by a well-trained observer. Measurement of DAP is more difficult than of SAP, and needs a longer training period, which represents one of the limitations of DU in cats. © ISFM and AAFP 2014.

Entities:  

Mesh:

Year:  2014        PMID: 24782457     DOI: 10.1177/1098612X14532087

Source DB:  PubMed          Journal:  J Feline Med Surg        ISSN: 1098-612X            Impact factor:   2.015


  7 in total

Review 1.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

2.  Comparison of home blood pressure and office blood pressure measurement in dogs and cats.

Authors:  Siu To Koo; Anthony P Carr
Journal:  Can J Vet Res       Date:  2022-07       Impact factor: 0.897

3.  Clinical, epidemiological and echocardiographic features and prognostic factors in cats with restrictive cardiomyopathy: A retrospective study of 92 cases (2001-2015).

Authors:  Valérie Chetboul; Peggy Passavin; Emilie Trehiou-Sechi; Vassiliki Gouni; Camille Poissonnier; Jean-Louis Pouchelon; Loic Desquilbet
Journal:  J Vet Intern Med       Date:  2019-03-28       Impact factor: 3.333

4.  Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats.

Authors:  Petra Cerna; Panos E Archontakis; Hester Ok Cheuk; Danièlle A Gunn-Moore
Journal:  J Feline Med Surg       Date:  2020-06-25       Impact factor: 2.015

5.  Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment.

Authors:  Maria Lyberg; Ingrid Ljungvall; Jens Häggström; Ellinor Ahlund; Lena Pelander
Journal:  J Vet Intern Med       Date:  2021-02-15       Impact factor: 3.333

6.  'The Mercury Challenge': feline systolic blood pressure in primary care practice - a European survey.

Authors:  Andrew Sparkes; Catherine Garelli-Paar; Thomas Blondel; Emilie Guillot
Journal:  J Feline Med Surg       Date:  2022-06-27       Impact factor: 1.971

7.  ACVIM consensus statement: Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats.

Authors:  Mark J Acierno; Scott Brown; Amanda E Coleman; Rosanne E Jepson; Mark Papich; Rebecca L Stepien; Harriet M Syme
Journal:  J Vet Intern Med       Date:  2018-10-24       Impact factor: 3.333

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.