Literature DB >> 24773040

Exploration of MR-guided head and neck hyperthermia by phantom testing of a modified prototype applicator for use with proton resonance frequency shift thermometry.

Wouter C M Numan1, Lorne W Hofstetter, Gyula Kotek, Jurriaan F Bakker, Eric W Fiveland, Gavin C Houston, Guido Kudielka, Desmond T B Yeo, Margarethus M Paulides.   

Abstract

Magnetic resonance thermometry (MRT) offers non-invasive temperature imaging and can greatly contribute to the effectiveness of head and neck hyperthermia. We therefore wish to redesign the HYPERcollar head and neck hyperthermia applicator for simultaneous radio frequency (RF) heating and magnetic resonance thermometry. In this work we tested the feasibility of this goal through an exploratory experiment, in which we used a minimally modified applicator prototype to heat a neck model phantom and used an MR scanner to measure its temperature distribution. We identified several distorting factors of our current applicator design and experimental methods to be addressed during development of a fully MR compatible applicator. To allow MR imaging of the electromagnetically shielded inside of the applicator, only the lower half of the HYPERcollar prototype was used. Two of its antennas radiated a microwave signal (150 W, 434 MHz) for 11 min into the phantom, creating a high gradient temperature profile (ΔTmax = 5.35 °C). Thermal distributions were measured sequentially, using drift corrected proton resonance frequency shift-based MRT. Measurement accuracy was assessed using optical probe thermometry and found to be about 0.4 °C (0.1-0.7 °C). Thermal distribution size and shape were verified by thermal simulations and found to have a good correlation (r(2 )= 0.76).

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24773040     DOI: 10.3109/02656736.2014.910615

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  7 in total

1.  Fast PRF-based MR thermometry using double-echo EPI: in vivo comparison in a clinical hyperthermia setting.

Authors:  Tetiana Dadakova; Johanna Gellermann; Otilia Voigt; Jan Gerrit Korvink; John Matthew Pavlina; Jürgen Hennig; Michael Bock
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

2.  Breath-hold MR-HIFU hyperthermia: phantom and in vivo feasibility.

Authors:  Chenchen Bing; Bingbing Cheng; Robert M Staruch; Joris Nofiele; Michelle Wodzak Staruch; Debra Szczepanski; Alan Farrow-Gillespie; Adeline Yang; Theodore W Laetsch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2019       Impact factor: 3.914

Review 3.  Status quo and directions in deep head and neck hyperthermia.

Authors:  Margarethus M Paulides; Gerda M Verduijn; Netteke Van Holthe
Journal:  Radiat Oncol       Date:  2016-02-11       Impact factor: 3.481

Review 4.  Integrating Loco-Regional Hyperthermia Into the Current Oncology Practice: SWOT and TOWS Analyses.

Authors:  Niloy R Datta; H Petra Kok; Hans Crezee; Udo S Gaipl; Stephan Bodis
Journal:  Front Oncol       Date:  2020-06-12       Impact factor: 6.244

5.  Quantitative, Multi-institutional Evaluation of MR Thermometry Accuracy for Deep-Pelvic MR-Hyperthermia Systems Operating in Multi-vendor MR-systems Using a New Anthropomorphic Phantom.

Authors:  Sergio Curto; Bassim Aklan; Tim Mulder; Oliver Mils; Manfred Schmidt; Ulf Lamprecht; Michael Peller; Ruediger Wessalowski; Lars H Lindner; Rainer Fietkau; Daniel Zips; Gennaro G Bellizzi; Netteke van Holthe; Martine Franckena; Margarethus M Paulides; Gerard C van Rhoon
Journal:  Cancers (Basel)       Date:  2019-11-02       Impact factor: 6.639

Review 6.  Current state of the art of regional hyperthermia treatment planning: a review.

Authors:  H P Kok; P Wust; P R Stauffer; F Bardati; G C van Rhoon; J Crezee
Journal:  Radiat Oncol       Date:  2015-09-17       Impact factor: 3.481

7.  Time-multiplexed two-channel capacitive radiofrequency hyperthermia with nanoparticle mediation.

Authors:  Ki Soo Kim; Daniel Hernandez; Soo Yeol Lee
Journal:  Biomed Eng Online       Date:  2015-10-24       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.