Literature DB >> 24771981

SELF ALIGNED TIP DEINSULATION OF ATOMIC LAYER DEPOSITED AL2O3 AND PARYLENE C COATED UTAH ELECTRODE ARRAY BASED NEURAL INTERFACES.

Xianzong Xie1, Loren Rieth1, Sandeep Negi1, Rajmohan Bhandari2, Ryan Caldwell3, Rohit Sharma1, Prashant Tathireddy1, Florian Solzbacher4.   

Abstract

The recently developed alumina and Parylene C bi-layer encapsulation improved the lifetime of neural interfaces. Tip deinsulation of Utah electrode array based neural interfaces is challenging due to the complex 3D geometries and high aspect ratios of the devices. A three-step self-aligned process was developed for tip deinsulation of bilayer encapsulated arrays. The deinsulation process utilizes laser ablation to remove Parylene C, O2 reactive ion etching to remove carbon and Parylene residues, and buffered oxide etch to remove alumina deposited by atomic layer deposition, and expose the IrOx tip metallization. The deinsulated iridium oxide area was characterized by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and electrochemical impedance spectroscopy to determine the morphology, surface morphology, composition, and electrical properties of the deposited layers and deinsulated tips. The alumina layer was found to prevent the formation of micro cracks on iridium oxide during the laser ablation process, which has been previously reported as a challenge for laser deinsulation of Parylene films. The charge injection capacity, charge storage capacity, and impedance of deinsulated iridium oxide were characterized to determine the deinsulation efficacy compared to Parylene-only insulation. Deinsulated iridium oxide with bilayer encapsulation had higher charge injection capacity (240 vs 320 nC) and similar electrochemical impedance (2.5 vs 2.5 kΩ) compared to deinsulated iridium oxide with only Parylene coating for an area of 2 × 10-4 cm2. Tip impedances were in the ranges of 20 to 50 kΩ, with median of 32 KΩ and standard deviation of 30 kΩ, showing the effectiveness of the self-aligned deinsulation process for alumina and Parylene C bi-layer encapsulation. The relatively uniform tip impedance values demonstrated the consistency of tip exposures.

Entities:  

Year:  2014        PMID: 24771981      PMCID: PMC3994722          DOI: 10.1088/0960-1317/24/3/035003

Source DB:  PubMed          Journal:  J Micromech Microeng        ISSN: 0960-1317            Impact factor:   1.881


  23 in total

Review 1.  Technology insight: future neuroprosthetic therapies for disorders of the nervous system.

Authors:  Richard A Normann
Journal:  Nat Clin Pract Neurol       Date:  2007-08

2.  An automated system for measuring tip impedance and among-electrode shunting in high-electrode count microelectrode arrays.

Authors:  Kabilar Gunalan; David J Warren; Justin D Perry; Richard A Normann; Gregory A Clark
Journal:  J Neurosci Methods       Date:  2008-12-27       Impact factor: 2.390

3.  Lifetime assessment of atomic-layer-deposited Al2O3-Parylene C bilayer coating for neural interfaces using accelerated age testing and electrochemical characterization.

Authors:  Saugandhika Minnikanti; Guoqing Diao; Joseph J Pancrazio; Xianzong Xie; Loren Rieth; Florian Solzbacher; Nathalia Peixoto
Journal:  Acta Biomater       Date:  2013-11-01       Impact factor: 8.947

4.  Laser exposure of Parylene-C insulated microelectrodes.

Authors:  E M Schmidt; M J Bak; P Christensen
Journal:  J Neurosci Methods       Date:  1995-11       Impact factor: 2.390

5.  Toward the ultimate metal microelectrode.

Authors:  G E Loeb; R A Peck; J Martyniuk
Journal:  J Neurosci Methods       Date:  1995-12       Impact factor: 2.390

6.  Plasma-assisted atomic layer deposition of Al(2)O(3) and parylene C bi-layer encapsulation for chronic implantable electronics.

Authors:  Xianzong Xie; Loren Rieth; Srinivas Merugu; Prashant Tathireddy; Florian Solzbacher
Journal:  Appl Phys Lett       Date:  2012-08-27       Impact factor: 3.791

7.  Characterization of parylene C as an encapsulation material for implanted neural prostheses.

Authors:  Christina Hassler; Rene P von Metzen; Patrick Ruther; Thomas Stieglitz
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-04       Impact factor: 3.368

8.  A Wafer-Scale Etching Technique for High Aspect Ratio Implantable MEMS Structures.

Authors:  R Bhandari; S Negi; L Rieth; F Solzbacher
Journal:  Sens Actuators A Phys       Date:  2010-07-01       Impact factor: 3.407

9.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array.

Authors:  P K Campbell; K E Jones; R J Huber; K W Horch; R A Normann
Journal:  IEEE Trans Biomed Eng       Date:  1991-08       Impact factor: 4.538

10.  Encapsulation of an integrated neural interface device with Parylene C.

Authors:  Jui-Mei Hsu; Loren Rieth; Richard A Normann; Prashant Tathireddy; Florian Solzbacher
Journal:  IEEE Trans Biomed Eng       Date:  2009-01       Impact factor: 4.538

View more
  2 in total

1.  Long-term reliability of Al2O3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation.

Authors:  Xianzong Xie; Loren Rieth; Layne Williams; Sandeep Negi; Rajmohan Bhandari; Ryan Caldwell; Rohit Sharma; Prashant Tathireddy; Florian Solzbacher
Journal:  J Neural Eng       Date:  2014-03-24       Impact factor: 5.379

Review 2.  Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine.

Authors:  Gaurav Balakrishnan; Jiwoo Song; Chenchen Mou; Christopher J Bettinger
Journal:  Adv Mater       Date:  2022-01-27       Impact factor: 30.849

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.