Literature DB >> 24658358

Long-term reliability of Al2O3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation.

Xianzong Xie1, Loren Rieth, Layne Williams, Sandeep Negi, Rajmohan Bhandari, Ryan Caldwell, Rohit Sharma, Prashant Tathireddy, Florian Solzbacher.   

Abstract

OBJECTIVE: We focus on improving the long-term stability and functionality of neural interfaces for chronic implantation by using bilayer encapsulation. APPROACH: We evaluated the long-term reliability of Utah electrode array (UEA) based neural interfaces encapsulated by 52 nm of atomic layer deposited Al2O3 and 6 µm of Parylene C bilayer, and compared these to devices with the baseline Parylene-only encapsulation. Three variants of arrays including wired, wireless, and active UEAs were used to evaluate this bilayer encapsulation scheme, and were immersed in phosphate buffered saline (PBS) at 57 °C for accelerated lifetime testing. MAIN
RESULTS: The median tip impedance of the bilayer encapsulated wired UEAs increased from 60 to 160 kΩ during the 960 days of equivalent soak testing at 37 °C, the opposite trend to that typically observed for Parylene encapsulated devices. The loss of the iridium oxide tip metallization and etching of the silicon tip in PBS solution contributed to the increase of impedance. The lifetime of fully integrated wireless UEAs was also tested using accelerated lifetime measurement techniques. The bilayer coated devices had stable power-up frequencies at ∼910 MHz and constant radio-frequency signal strength of -50 dBm during up to 1044 days (still under testing) of equivalent soaking time at 37 °C. This is a significant improvement over the lifetime of ∼100 days achieved with Parylene-only encapsulation at 37 °C. The preliminary samples of bilayer coated active UEAs with a flip-chip bonded ASIC chip had a steady current draw of ∼3 mA during 228 days of soak testing at 37 °C. An increase in the current draw has been consistently correlated to device failures, so is a sensitive metric for their lifetime. SIGNIFICANCE: The trends of increasing electrode impedance of wired devices and performance stability of wireless and active devices support the significantly greater encapsulation performance of this bilayer encapsulation compared with Parylene-only encapsulation. The bilayer encapsulation should significantly improve the in vivo lifetime of neural interfaces for chronic implantation.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24658358      PMCID: PMC4077846          DOI: 10.1088/1741-2560/11/2/026016

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  35 in total

1.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.

Authors:  Roy Biran; Dave C Martin; Patrick A Tresco
Journal:  J Biomed Mater Res A       Date:  2007-07       Impact factor: 4.396

Review 2.  Technology insight: future neuroprosthetic therapies for disorders of the nervous system.

Authors:  Richard A Normann
Journal:  Nat Clin Pract Neurol       Date:  2007-08

3.  An automated system for measuring tip impedance and among-electrode shunting in high-electrode count microelectrode arrays.

Authors:  Kabilar Gunalan; David J Warren; Justin D Perry; Richard A Normann; Gregory A Clark
Journal:  J Neurosci Methods       Date:  2008-12-27       Impact factor: 2.390

4.  A high-performance brain-computer interface.

Authors:  Gopal Santhanam; Stephen I Ryu; Byron M Yu; Afsheen Afshar; Krishna V Shenoy
Journal:  Nature       Date:  2006-07-13       Impact factor: 49.962

5.  Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve.

Authors:  Natalia Lago; Dolores Ceballos; Francisco J Rodríguez; Thomas Stieglitz; Xavier Navarro
Journal:  Biomaterials       Date:  2005-05       Impact factor: 12.479

6.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array.

Authors:  P K Campbell; K E Jones; R J Huber; K W Horch; R A Normann
Journal:  IEEE Trans Biomed Eng       Date:  1991-08       Impact factor: 4.538

7.  HermesC: low-power wireless neural recording system for freely moving primates.

Authors:  Cynthia A Chestek; Vikash Gilja; Paul Nuyujukian; Ryan J Kier; Florian Solzbacher; Stephen I Ryu; Reid R Harrison; Krishna V Shenoy
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-06-02       Impact factor: 3.802

8.  Electrical performance of penetrating microelectrodes chronically implanted in cat cortex.

Authors:  Sheryl R Kane; Stuart F Cogan; Julia Ehrlich; Timothy D Plante; Douglas B McCreery; Philip R Troyk
Journal:  IEEE Trans Biomed Eng       Date:  2013-02-26       Impact factor: 4.538

9.  Encapsulation of an integrated neural interface device with Parylene C.

Authors:  Jui-Mei Hsu; Loren Rieth; Richard A Normann; Prashant Tathireddy; Florian Solzbacher
Journal:  IEEE Trans Biomed Eng       Date:  2009-01       Impact factor: 4.538

10.  Characterization of a-SiC(x):H thin films as an encapsulation material for integrated silicon based neural interface devices.

Authors:  Jui-Mei Hsu; Prashant Tathireddy; Loren Rieth; A Richard Normann; Florian Solzbacher
Journal:  Thin Solid Films       Date:  2007-11-01       Impact factor: 2.183

View more
  18 in total

1.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

2.  Recent Advances in Neural Electrode-Tissue Interfaces.

Authors:  Kevin Woeppel; Qianru Yang; Xinyan Tracy Cui
Journal:  Curr Opin Biomed Eng       Date:  2017-09-23

3.  The robo-pigeon based on the multiple brain regions synchronization implanted microelectrodes.

Authors:  Rui-Tuo Huai; Jun-Qing Yang; Hui Wang
Journal:  Bioengineered       Date:  2016-07-03       Impact factor: 3.269

4.  SiC protective coating for photovoltaic retinal prosthesis.

Authors:  Xin Lei; Sheryl Kane; Stuart Cogan; Henri Lorach; Ludwig Galambos; Philip Huie; Keith Mathieson; Theodore Kamins; James Harris; Daniel Palanker
Journal:  J Neural Eng       Date:  2016-06-21       Impact factor: 5.379

5.  A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication.

Authors:  David K Piech; Benjamin C Johnson; Konlin Shen; M Meraj Ghanbari; Ka Yiu Li; Ryan M Neely; Joshua E Kay; Jose M Carmena; Michel M Maharbiz; Rikky Muller
Journal:  Nat Biomed Eng       Date:  2020-02-19       Impact factor: 25.671

6.  Long-term recording reliability of liquid crystal polymer µECoG arrays.

Authors:  Virginia Woods; Michael Trumpis; Brinnae Bent; Kay Palopoli-Trojani; Chia-Han Chiang; Charles Wang; Chunxiu Yu; Michele N Insanally; Robert C Froemke; Jonathan Viventi
Journal:  J Neural Eng       Date:  2018-09-24       Impact factor: 5.379

7.  Recessed Traces for Planarized Passivation of Chronic Neural Microelectrodes.

Authors:  Nicholas F Nolta; Pejman Ghelich; Martin Han
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

8.  Fabrication and modeling of recessed traces for silicon-based neural microelectrodes.

Authors:  Nicholas F Nolta; Pejman Ghelich; Alpaslan Ersöz; Martin Han
Journal:  J Neural Eng       Date:  2020-10-08       Impact factor: 5.379

Review 9.  Evaluation methods for long-term reliability of polymer-based implantable biomedical devices.

Authors:  Dong Hyeon Lee; Chae Hyun Kim; Jiman Youn; Joonsoo Jeong
Journal:  Biomed Eng Lett       Date:  2021-04-15

10.  The Argo: a high channel count recording system for neural recording in vivo.

Authors:  Kunal Sahasrabuddhe; Aamir A Khan; Aditya P Singh; Tyler M Stern; Yeena Ng; Aleksandar Tadić; Peter Orel; Chris LaReau; Daniel Pouzzner; Kurtis Nishimura; Kevin M Boergens; Sashank Shivakumar; Matthew S Hopper; Bryan Kerr; Mina-Elraheb S Hanna; Robert J Edgington; Ingrid McNamara; Devin Fell; Peng Gao; Amir Babaie-Fishani; Sampsa Veijalainen; Alexander V Klekachev; Alison M Stuckey; Bert Luyssaert; Takashi D Y Kozai; Chong Xie; Vikash Gilja; Bart Dierickx; Yifan Kong; Malgorzata Straka; Harbaljit S Sohal; Matthew R Angle
Journal:  J Neural Eng       Date:  2021-02-24       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.